![Adtec RD-71 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/adtec/rd-71/rd-71_user-manual_2854109021.webp)
16QAM_3/4
16QAM_7/8
8PSK_2/3
8PSK_5/6
8PSK_8/9
Symbol
Rate
The number of symbols transmitted per second
in Msym/s. The amount of data per symbol is
dependant upon the modulation type, e.g. QPSK,
8PSK, etc.
maximum value is determined by
feature key.
Acquisition
Range
Acquisition Range is defined as the range of
frequencies that the tuner will scan in order to
achieve carrier synchronization. Allows the
operator to select the range of frequencies that
the RF tuner will sweep through to acquire the
carrier. e.g. If the desired carrier is at 1.080GHz
and the Acquisition Range is set to 5MHz, the RF
tuner will sweep through 1.080GHz ± 2.5MHz to
acquire the carrier.
0 - 7.5MHz
Roll-off
The rolloff selection will determine the shape of
the input filter. The occupied bandwidth of the
modulated signal is the symbol rate multiplied
by (1+α) where alpha (α) is the rolloff factor
(%). By using a lower alpha, carriers can be
spaced closer together on a given transponder
or an increased symbol rate can be realized for a
given bandwidth.
AUTO
5%
10%
15%
20%
25%
35%
ISI Control
ISI Control configures the receiver for
Multistream Mode (Enabled) or Singlestream
Mode (Disabled, Default). If the receiver is
operating in Multistream Mode, an ISI value
must be entered.
SINGLESTREAM
MULTISTREAM
ISI
Multistream ISI (input stream identifier) is
required for multistream applications. If
Multistream Mode is enabled, BBHeaders
containing this value will be demodulated and
output to the receiver.
0 - 255
LNB State
Enables or disables the LNB control
OFF
ON
LNB Polarity This control is primarily used in “Universal” LNB
applications. The LNB Polarity control allows for
LNB polarization selection; the 13VDC source will
select the Vertical polarity and the 18VDC source
will select the horizontal polarity. For typical “C”
and “Ku” band applications, the 18 VDC option is
recommended.
OFF
H(18V)
V(13V)
LNB Tone
This control is used only for Universal LNB
applications. A universal LNB can route the high
or low band from either polarity to the IRD. The
high band is selected by enabling the 22 kHz
tone and the low band is selected when the 0 Hz
tone is enabled.
0KHz
22KHz
21
Содержание RD-71
Страница 1: ...RD 71 10 bit 1080P Integrated Receiver Decoder USER GUIDE v2 02 10 1 ...
Страница 5: ...Application Diagrams Turn Around and Service Filtering 5 ...
Страница 6: ...Zixi IP Transport Zixi Link point to point or Zixi Receive point to multi point 6 ...
Страница 9: ...6 NC No Connect 7 GND Ground 8 L Left 9 R Right 9 ...
Страница 12: ...Front Panel Operation The front panel LCD and keypad can be used to configure and monitor your device 12 ...
Страница 32: ...32 ...
Страница 45: ...RF Params LB model 45 ...
Страница 56: ...Bars Tones and ID 56 ...
Страница 101: ...101 ...
Страница 109: ...109 ...