Adtec RD-71 Скачать руководство пользователя страница 102

 

RD-71 Zixi Setup Guide 

Where previous protocols, such as TCP, UDP and RTP have various constraints, Zixi is designed to 
overcome protocol limitations for broadcast quality video delivery.  There are two Zixi options 
available on the RD-71, Zixi-Link and Zixi-Receive. 

Zixi-Link is a point to point IP transport using Zixi technology to provide reliable video service over 
nondeterministic networks.  If the IRD is behind a firewall, port forwarding is required.  In this mode, 
Zixi parameters are configured on the sender (or Adtec encoder). 

Zixi-Rx is used in point to multipoint applications and is combined with a Zixi Broadcaster server.  In 
ZIXI- Rx mode, the IRD is acting as a client and can therefore bypass the need for firewall forwarding 
rules to the IRD.  In this mode, all Zixi parameters are configured on the receiver (or RD-71). 

Zixi uses a combination of FEC and ARQ to deliver packets.  The amount of latency between 
end-points, the amount of packet loss incurred between end-points and the bandwidth requirements 
of the link all affect how the FEC and latency settings should be configured.  These three items should 
be taken into consideration when doing initial setup. 

 

Setting up Zixi-Link 

To use Zixi-Link, the feature key must be enabled.  This may be verified on the Upgrade -> Features 
tab. 

 

If the key is not enabled please contact your sales representative, 

[email protected]

Select ZIXI-Link under IP Rx Mode. 

 

The Web interface will prompt for a reboot confirmation, click Apply. 

 

 

102

 

Содержание RD-71

Страница 1: ...RD 71 10 bit 1080P Integrated Receiver Decoder USER GUIDE v2 02 10 1 ...

Страница 2: ...ators Transport Audio Decode System Front Panel LCD Front Panel Button Controls Front Panel Reset Front Panel Menus Services Menu RF Rx Menu LB Option RF Rx Menu PRX Option IP Rx Menu Video Menu Audio Menu VBI Menu CAS Menu IP Tx Menu System Menu Login Duration Com2 Host Name Firmware Feature Menu Getting Connected Intro to Adtec User Interfaces Web UI Interface Ethernet Access Zero Configuration ...

Страница 3: ...Management Operational Information DVB S DVB S2 AUTO Modes DVB S2 Recommended use of Pilots RF Profiles UDP RTP FEC TCP IP Rx Multicast Reception Address Unicast Reception Address Unicast Multicast Reception Dolby E Dolby D LPCM and Mpeg 1 Layer 2 AFD Active Format Description Genlock System TS Out Decrypt Service Filtering Configure Service Filter on ASI Firmware Upgrade via Web User Interface De...

Страница 4: ...nd Audio Physical and Operational L Band Demodulator LB option DVB S2X L Band Demodulator PRX option Appendix C Adtec Digital Support Service Appendix D Electrical Device Compliance Notices Safety Warnings and Cautions Compliance Notices FCC Industry Canada European Union EMC Directive Conformance Statement Trademarks Copyrights 4 ...

Страница 5: ...Application Diagrams Turn Around and Service Filtering 5 ...

Страница 6: ...Zixi IP Transport Zixi Link point to point or Zixi Receive point to multi point 6 ...

Страница 7: ...ce over the mounting holes in the rack 3 Slide the RD 71 into position in the rack 4 Secure the RD 71 to the rack by installing four rack screws through the front mounting holes and tightening 5 If needed secure a grounding wire use the grounding location on the rear panel of the RD 71 Back Panel Connector Description Processor Power 1 2 Redundant AC Power Standard 3 pin computer power plug Auto r...

Страница 8: ...CVBS Out 75 Ohm BNC Standard Definition Composite Video Output Digital Video Digital Video Output SDI Out Banks x4 Outputs from decoder Video Audio VBI SMPTE 259M C SD SMPTE 292M HD SMPTE 424M 3G SDI Bank A x2 SD HD 3G SDI BNC Outputs SDIALT Bank B x1 SFP for Optical SFP module SD HD 3G SDI Output and x1 SD HD 3G SDI BNC note 3G SDI Outputs have selectable Level A and Level B Dual Link output cont...

Страница 9: ...6 NC No Connect 7 GND Ground 8 L Left 9 R Right 9 ...

Страница 10: ...n RJ45 Function 1 Carrier Detect CD 2 No Connect Carrier Detect DCD 2 Receive Data RXD 6 Transmit Data TXD 3 Transmit Data TXD 5 Receive Data RXD 4 Data Terminal Ready DTR 1 Data Set Ready DSR 5 Ground GND 4 Ground GND 6 Data Set Ready DSR 3 Data Terminal Ready DTR 7 Request to Send RTS 7 Clear to Send CTS 8 Clear to Send CTS 8 Request to Send RTS 9 Ring Indicator RI NC NA No Connect Not available...

Страница 11: ...usage in programming the parallel port GPIO Pinout PIN Designation Function 1 NC No Connect 2 D3 reserved for future functionality 3 D2 reserved for future functionality 4 D1 reserved for future functionality 5 D0 reserved for future functionality 6 NC No Connect 7 5VDC 5V DC 8 GND ground 9 TTL Tally reserved for future functionality Parport Pinout PIN Designation Function 1 NC No Connect 2 D3 Dat...

Страница 12: ...Front Panel Operation The front panel LCD and keypad can be used to configure and monitor your device 12 ...

Страница 13: ...are enabled Audio Decode Indicator Function A1 through A8 Off Audio engine is not active On Audio engine is actively decoding or performing passthru Blinking Audio engine is in a failure mode no passthru or audio decoding System Indicator Function Alarm Off No system alarms On System alarm NTP or FAN alarm BISS Off Decryption configuration is turned OFF On Decryption configuration is set to BISS1 ...

Страница 14: ...t Panel LCD 1 Feedback State There are several quick view menu screens available when in regular feedback state You can view any of these quick view status screens by using the up and down arrow buttons 14 ...

Страница 15: ... arrow when in this state to navigate through the network menu Front Panel Button Controls Using the Mode Select Enter Escape and directional buttons the user can control the unit via the front panel Control Function Mode button Mode will cycle through top level menus Select Select will enter into menus or edit mode Enter Enter submits any edited configurations 15 ...

Страница 16: ...e submenus While editing a configuration up and down also moves through highlighted selections Programming Keypad For value entry F1 functions as a or operator F2 functions as a decimal or period Front Panel Reset Should you need to reset your device you can do so via the front panel by pressing the MODE ESCAPE and RIGHT ARROW keys simultaneously Release all three buttons simultaneously 16 ...

Страница 17: ...unction Options List of Services Allows selection of a service from a list of services per input ALL ASI RF1 RF2 IP Decode First Found Allows you to configure the RD 71 to decode the first valid program found on any input ASI RF1 RF2 IP 17 ...

Страница 18: ...hough some other variants are included If the desired L O frequency is not listed select either C Manual or Ku Manual and enter the L O frequency in the Manual L O field C 5150 KU 11300 KU 10750 KU 10600 KU 10000 KU 9750 KU 9600 C MANUAL KU MANUAL Manual LO Allows manual entry of the LNB Local Oscillator frequency provided that either C Manual or Ku Manual is selected from the Local Oscillator pul...

Страница 19: ...r Universal LNB applications A universal LNB can route the high or low band from either polarity to the IRD The high band is selected by enabling the 22 kHz tone and the low band is selected when the 0 Hz tone is enabled 0KHz 22KHz Modulation Type Allows the selection of the mod type AUTO DVBS DVBS 2 Symbol Rate The number of symbols transmitted per second The amount of data per symbol is dependan...

Страница 20: ...quencies can be used to determine if spectrum inversion occurs using the following rules If the Downlink frequency is less than the Local Oscillator frequency then spectrum inversion does occur If the Downlink frequency is greater than the Local Oscillator frequency then spectrum inversion does not occur Range dependent upon LO configuration L Band Allows the operator to enter the L Band frequency...

Страница 21: ...creased symbol rate can be realized for a given bandwidth AUTO 5 10 15 20 25 35 ISI Control ISI Control configures the receiver for Multistream Mode Enabled or Singlestream Mode Disabled Default If the receiver is operating in Multistream Mode an ISI value must be entered SINGLESTREAM MULTISTREAM ISI Multistream ISI input stream identifier is required for multistream applications If Multistream Mo...

Страница 22: ...ormation can be found in this menu RF Profile Menu PROFILE RUN Allows operator to review list of profiles and choose one to load run PROFILE SAVE Allows operator to save the current running config as a profile stored on the unit PROFILE DELETE Allows operator to review list of profiles and delete a selected profile 22 ...

Страница 23: ...an advanced configuration used for redundancy security or IGMPv3 multicast applications It does not function for unicast reception 0 0 0 0 255 255 255 255 Multicast Connector The multicast connector configuration determines the physical port of where the IP stream will be received IP 1 or IP 2 ports IP1 IP2 Latency Multicast Latency sets the latency delay before the decoder begins playback from th...

Страница 24: ...r Recovery Multicast Error Recovery sets the timeout value for recovery of multicast receive after decoder error condition is detected The default error recovery timeout is configuration value is 10000 milliseconds 33 600000ms 10000ms default 24 ...

Страница 25: ...ideo output on fault BLANK Only blanking on fault BLANKTONES Blanking and tones on fault BLANKOVERLAY Blanking and overlay on fault BLANKTONESOVERLAY Blanking tones and overlay on fault When a type with BLANK is selected the current bars matte setting will be applied When a type with TONES is selected the current tones setting will be applied When a type with OVERLAY is selected the current device...

Страница 26: ...Downscaling SDI setting determines whether the SDI bank SDI Output 1 and 2 will be output natively or downscaled to SD OFF SD Downscaling SDIALT The Downscaling SDI setting determines whether the SDI bank SDI Output 3 and 4 will be output natively or downscaled to SD OFF SD Genlock Menu Genlock Mode Configures the genlock operation of the decoder SLAVE is primarily used for 3D applications and REM...

Страница 27: ...e grain adjustment that can adjust within a single clock The increments are 1 64th of a clock The valid range is 0 to 63 0 63 Genlock Status Shows if GENLOCK input is currently being used for the decoder or in FREE RUN mode Genlock CVBS Out This configuration is used generally with 3D applications The MASTER unit CVBS configuration must be configured as SYNC VIDEO CVBS output is video SYNC CVBS ou...

Страница 28: ...hould be configured for Professional the default setting In rare cases third party encoders or multiplexers may have unstable PCR PTS timing In these cases professional may cause intermittent drop outs as the audio sub system attempts to retain tight lip sync If this occurs please change lipsync setting to Relaxed PROFESSIONAL default RELAXED_20_MS RELAXED_80_MS RELAXED_1_S Audio 1 8 Audio PID All...

Страница 29: ...gured to a value within range Valid ranges for Dolby E line placement are resolution and frame rate dependent If the configured value is not valid the system will use the valid line used by the AUTO mode The Dolby E line status information can be used to see the actual Dolby E line placement View Dolby E line table for more information 1 4096 1 AUTO Analog Vol Pair 1 2 Adjusts the analog volume of...

Страница 30: ...ed SDI pair AUDIO4 Route Audio 4 to the selected SDI pair AUDIO5 Route Audio 5 to the selected SDI pair AUDIO6 Route Audio 6 to the selected SDI pair AUDIO7 Route Audio 7 to the selected SDI pair AUDIO8 Route Audio 8 to the selected SDI pair 30 ...

Страница 31: ...t captions if present SDI Line Number Configures the SDI ANC line output of EIA 608 708 Closed Captions SDI Output Port 1 and 2 0 Disabled 7 22 SDI Alt Line Number Configures the SDI Alternate ANC line output of EIA 608 708 Closed Captions SDI Output Port 3 and 4 0 Disabled 7 22 Teletext CVBS Line Number Enables Disables the CVBS SD SDI port line number for waveform Teletext 0 Disabled 22 Output t...

Страница 32: ...32 ...

Страница 33: ...he 14 digit hexadecimal User ID injected ID used for decryption user defined using the numeric keypad TS Out Decrypt The TS Out Decrypt configuration determines if the ASI output should mirror the selected input OFF thus preserving any encrypted streams or if it should be decrypted free to air ON OFF the default configuration is recommended for users needing to redistribute transport streams in th...

Страница 34: ... outgoing unicast requires a different gateway from the configured system default gateway A route is automatically added when the unit is configured for transmit and a Unicast Gateway exists The route is deleted if set to 0 0 0 0 or Multicast Mode set to OFF user defined numeric field in format xxx xxx xxx xxx DVB per IP Configures the amount of DVB transport stream packets 188 bytes per DVB packe...

Страница 35: ...lity 8 Maximize throughput 16 Minimize delay TTL Time to Live specifies the number of iterations or transmissions the packet can undergo before it is discarded user defined using the numeric keypad Tx Connector sets the physical connector on the rear of the unit to use for multicast transmit purposes on the indicated encode channel IP 1 IP 2 35 ...

Страница 36: ...t arrow Press Enter Duration The front panel also has a login duration feature This setting allows the user to specify a time frame in minutes until the unit will automatically log itself out Action Press mode until you see the System Menu Press Select Press the Down arrow Press Select Using the Up and Down arrows select the value you wish Press Enter to save your selection Possible Configurations...

Страница 37: ...c keypad Default is 192 168 20 48 IP 2 Mask Defines the unit relative to the rest of your network user defined using the numeric keypad Default is 255 255 255 0 IP 2 DHCP The Dynamic Host Configuration Protocol allows your device to self locate network IP 2 parameters On finds own DHCP Address Off defaults to last entered IP Address Default is OFF Gateway IP Address The gateway is a routing mechan...

Страница 38: ...Controls the status ON OFF of the Simple Network Management Protocol SNMP feature We support SNMPv2c OFF ON Read only community The Simple Network Management Protocol SNMP Read Only Password Default Value adtec user defined using the numeric keypad default adtec Read write community The Simple Network Management Protocol SNMP Read Write Password Default Value none user defined using the numeric ke...

Страница 39: ...ero conf name and is viewable in web browser title bar Read Only Firmware Item Function Options Firmware Version Reports the currently running firmware version of your device Read Only Feature Menu Item Function Options Permanent ID Shows the units unique permanent identifier This ID is required by support when purchasing unit capability keys Read Only Temporary ID Shows the units unique temporary...

Страница 40: ...network is DHCP enabled and you prefer that over a static IP you can turn on DHCP for the device via the front panel System Network menu Zero Configuration Access Adtec Digital has adopted zero configuration networking technology streamlining the setup and configuration processes for our products The use of this technology enables automatic discovery of Adtec devices and services on an IP network ...

Страница 41: ...anel may be collapsed or expanded by clicking on the icon with the double up or double down arrows The heading of each status may contain an LED that summarizes the current state of the individual status box Green represents OK Yellow represents Potential Warning and Red represents an alarm Firmware and Temperature The top left hand status displays a logo of the product Firmware version and operat...

Страница 42: ...us displays information about the IP Rx configuration Further detailed status can be found on the Input IP Rx Params page The LED will be grey if the input is disabled red if an input is not detected or green if a stream is detected The current IP Rx configuration is also displayed for average bit rate detected current buffer level and the protocol used for reception The IRD automatically detects ...

Страница 43: ...iguration PID decimal and the encoded audio rate kb s IP Tx Status The IP Tx status window displays information about the IP Tx profiles that can be configured Status will be green if the Tx profile is set to ENABLED and if link is detected on the configured output The configured IP destination parameters IP Address Port Source Port Protocol and DVB TS Packets per IP Packet can be viewed in this s...

Страница 44: ...the desired input to Select First Found The Reset input button can be used to clear inputs and restart the decode session In rare cases this may be needed if the decoder does not recover properly The reset button will reset the decode session in a few seconds as opposed to waiting for an entire system reboot Manual Selection occurs when the SELECT button is pressed next to a listed service The dec...

Страница 45: ...RF Params LB model 45 ...

Страница 46: ...re RF tuner parameters and see advanced tuner status State Enables or Disables the RF Input Note When RF1 and RF2 are both enabled maximum tuner performance is affected If this condition occurs please disable one of the RF inputs Please view tuner specifications for 46 ...

Страница 47: ... 13VDC source will select the Vertical polarity and the 18VDC source will select the horizontal polarity For typical C and Ku band applications the 18 VDC option is recommended LNB 22kHz Tone This control is used only for Universal LNB applications A universal LNB can route the high or low band from either polarity to the IRD The high band is selected by enabling the 22 kHz tone and the low band i...

Страница 48: ...al symbol rate ISI ISI input stream identifier is required for multistream applications If a multistream RF source is detected BBHeaders containing this value will be demodulated and output to the receiver This value has no effect during single stream applications PLS Mode PLS Mode determines the Gold sequence code to use for descrambling DEFAULT or 0 CODE1 User entered sequence in PLS Code 1 or C...

Страница 49: ...u Manual is selected from the Local Oscillator pulldown menu Local Oscillator The Local Oscillator L O control specifies the frequency of the LNB local oscillator The standard L O frequencies for C and Ku bands are 5150MHz and 10750MHz respectfully although some other variants are included If the desired L O frequency is not listed select either C Manual or Ku Manual and enter the L O frequency in...

Страница 50: ...S2 and DVB S2X It is recommended to use the DVB S2 DVB S2X mode for all S2 S2X carriers when the unit is keyed for S2X capability Symbol Rate Symbol Rate is defined for digital communications as the number of symbols per second The amount of data per symbol depends on the modulation type Units for this field are expressed in Msym s The default valid range is 1 54 Msym s For more information contac...

Страница 51: ...arization selection the 13VDC source will select the Vertical polarity and the 18VDC source will select the horizontal polarity For typical C and Ku band applications the 18 VDC option is recommended Tone This control is used only for Universal LNB applications A universal LNB can route the high or low band from either polarity to the IRD The high band is selected by enabling the 22 kHz tone and t...

Страница 52: ...nector setting sets the physical connector on the rear of the unit to use for IP receive purposes The appropriate interface will be used based on this connector setting Currently IP 1 0 and IP 2 1 connectors are supported Address UDP RTP Mode Multicast IPA sets the multicast receive Group IP address IP Multicast receiving is supported from compatible streamers The range of the multicast group IP i...

Страница 53: ...nfigurable range of the MULTICASTLATENCY is dependent upon bit rate 10MB buffer with the floor configurable for 4ms The accuracy of the actual latency compared to the configured latency is dependent upon the bit rate and protocol used The RD adjusts the IP reception rate to match the configured multicast latency setting and is more accurate in UDP RTP reception Timeout Sets the timeout value for r...

Страница 54: ...configuration and environment Round trip time measures how long a packet takes to travel to the broadcaster or encoder and back This calculation is important when configuring latency and determining error correction configurations for the application Total Packets are how many packets have been received since the IRD started receiving Jitter is the variation in the delay of received packets Larger...

Страница 55: ... packet lost Table Video Audio NULL etc FEC Recovered shows how many dropped FEC packets have been successfully recovered ARQ Recovered shows how many dropped packets have been successfully recovered by ARQ FEC Packets shows how many FEC packets have been received ARQ Packets show how many ARQ packets have been received FEC Bitrate shows the data rate of the FEC overhead Duplicates shows the numbe...

Страница 56: ...Bars Tones and ID 56 ...

Страница 57: ...igured for Pass through operation LPCM Dolby E Dolby D etc internal tone generation does not function for the pass through channels Advanced Tones allows the operator to mute Left Right channels or change tone frequency As of 2 01 XX Firmware Bars Tones ID functionality has some ties to the Fault Mode configuration Fault Mode via the Video Output tab Adtec is working to break dependencies for futu...

Страница 58: ...ile will restart the decoding process with the newly loaded configuration and will save that configuration for use upon a reboot Create New Creates a new profile of the currently saved decoder state Load Loads or runs the profile Delete Deletes the profile from the unit Download Downloads the profile to a local file Web UI Video Genlock is used for synchronizing the SDI output to a bi level or tri...

Страница 59: ...just Horizontal adjustment defines the difference in the SYNC IN HSYNC and output HSYNC Typically this should be in the range of 0 to 1 line in clocks For example a 1080I output could be adjusted from 0 to 2200 Negative values can be entered Vertical Adjust Vertical adjustment defines the difference in the SYNC IN VSYNC and output VSYNC Typically this should be in the range of 0 to 1 frame in line...

Страница 60: ... The mapping is individually configurable for each set of outputs SDI and SDIALT If 3G SDI output does not appear on the downstream device the device may not support the currently configured mapping mode Use SDI3GLEVEL to change the mapping mode Down Scaling The SDI out scale configuration controls the format of the SDI output banks SDI and SDIALT Each bank has a unique configuration allowing simu...

Страница 61: ...ator to BARS BARS TONES SRV ID Sets RVD to BLANKTONESOVERLAY and the color bar generator to BARS HOLD LAST FRAME STOP DECODING Video output will stop at boot time and will hold last frame of video and output no audio on signal loss HOLD LAST FRAME BLACK Video output will be black with no audio at boot time and will hold last frame of video and output no audio on signal loss HOLD LAST FRAME BARS Vi...

Страница 62: ...low 1 Service Name 2 Service Provider 3 Input 4 TMR For example a value of 3 will display lines 1 3 A value of 2 will display lines 1 2 These lines can not be selected individually OSD Service Blink Blink is used as a bit defined field When used with the string command it will blink the entire string not individual lines or characters For example binary number 1010 will blink the 2nd and 4th line ...

Страница 63: ...the audio sub system should behave with incoming transport streams When it is desired for the audio subsystem to retain tight lipsync and adjust on upstream lip sync changes this should be configured for Professional the default setting In rare cases third party encoders or multiplexers may have unstable PCR PTS timing In these cases professional may cause intermittent drop outs as the audio sub s...

Страница 64: ...output mode does not equal the bitstream audio coding mode acmod then the decoder will perform downmixing or fill channels with zero values to meet the desired output configuration Dolby E Line This is used to configure Dolby E placement in the SDI output and is configurable per audio engine When set to AUTO 1 the default configuration the Dolby E line is placed within the valid line number range ...

Страница 65: ...NOTE SDI Audio Matrix can be used for audio duplication Web UI CAS CAS allows an operator to configure BISS decryption and TS output configurations Read more in the TS Out Decryption section 65 ...

Страница 66: ...pt the transmission stream Clear Session Word The session keys used for decryption MODE BISS_1 uses a 12 digit hexadecimal Clear Session Word MODE BISS_E_XXX uses a 16 digit hexadecimal Encrypted Session Word Encrypted Session Word MODE BISS_E_XXX uses a 16 digit hexadecimal Encrypted Session Word User ID One Valid in MODE BISS_E_ONE ONLY The 14 digit hexadecimal User ID used for decryption User I...

Страница 67: ...ut the ASI output will remain unaltered ON is recommended for users needing to redistribute the ASI output as a free to air SPTS MPTS All programs will be decrypted with the user entered BISS key The RD does not support BISS encrypted streams over 120Mb s at this time If an entire MPTS needs to be decrypted TS Out Decrypt ON the rate must not exceed 120Mb s If an encrypted MPTS exceeds the 120Mb s...

Страница 68: ...form captions on CVBS and SD SDI set CVBS to line 21 When set to 0 waveform captions are disabled To enable ancillary digital 708 captions on SDI or SDIALT select a line number next for the desired output Teletext Waveform and OP47 teletext is supported on CVBS SDI and SDIALT To enable 68 ...

Страница 69: ...ration Not supported at this time 2 01 XX SMPTE 2038 The Adtec decoder supports Transport Stream to SDI ancillary data pass through via SMPTE 2038 VBI Stats shows the DID SDID and data count for the SDI outputs if captions or AFD is enabled The AFD code can be seen in hex and the aspect ratio flag is also displayed Web UI TS Output ASI Tx configures Service Filtering on the ASI Output Read more in...

Страница 70: ...t rate will be the sum of all PIDs configured for the output minimal NULL stuffing When set to NATIVE the output TMR is set to match the INPUT source TMR MANUAL is a user defined rate Manual TMR When ASI Output TMR is set to MANUAL this field may be configured for a value in Mb s IP Tx configures IP Destinations and Service Filtering for the IP Outputs A summary table of active configuration can b...

Страница 71: ...or unicast transmissions This must be configured if the outgoing unicast requires a different gateway from the configured system default gateway A route is automatically added when the unit is configured for transmit and a Unicast Gateway exists The route is deleted if set to 0 0 0 0 or Multicast Mode set to OFF NOTE An unwanted route removal corner case exists at this time This can occur for appl...

Страница 72: ...ue from 1 to 255 that specifies the number of iterations or transmissions the packet can undergo before it is discarded The default value is 7 FEC Mode T he Forward Error Correction technique implemented in this encoder conforms to the SMPTE 2022 1 2007 standard for the carriage of real time Video Audio content over IP networks When enabled the encoder will send two FEC streams to the same destina...

Страница 73: ... if the SVC FLTR KEY is enabled Manual TMR User defined IP TMR in Mb s IP Filter IP Filter enables or disables the configured RD 70 service filter Service Filtering allows users to filter or cherry pick programs destined for the output from an MPTS input Up to 5 services can be mapped to the IP Filtered output NOTE This value is only selectable if the SVC FLTR KEY is enabled Web UI System System a...

Страница 74: ...uilt in Bonjour locator in the Apple Safari browser or the plug ins readily available for Internet Explorer or Firefox browsers you can locate Adtec Digital devices via serial number or custom name Gateway Address Gateway IPA is an address on a TCP IP Network that serves as an access point to another network Each Adtec Digital device is limited to one Gateway IPA Nameserver IP NAMESERVER is used t...

Страница 75: ...s the network subnet mask assigned to the unit Consult your organization s Network Administrator for the IP Subnet mask for your unit s MAC Address Displays the units physical MAC address Link Status Displays whether the connector detect link or not Link Speed Displays the connected link speed if the link is up NTP Address NTP Address is the IP address of an external source for time It should be e...

Страница 76: ...ace is available for special cases such as system integration network management systems NMS advanced troubleshooting developers and testers An operator does not generally interface with the API directly but instead will interface with third party software If an operator does need to interface with the API generally it will be for troubleshooting purposes with the aid of a support representative A...

Страница 77: ...Programs and Features catgegory 4 Place a check mark inside of Telnet Client and click OK 5 Please be patient as Windows enables Telnet capability it can take several minutes SNMP Interface The SNMP or Simple Network Management Protocol interface is an advanced interface to interact with Adtec products This interface is available for special cases such as system integration network management syst...

Страница 78: ...tion behaviors and the available security features Web UI Authentication Modes The Web UI authentication can be configured to operate in one of three modes OFF No authentication is required When set to OFF all users that navigate to the web interface will be granted admin privileges and will be directed to the home page when typing in the IP address of the unit The home page is the Input RD Servic...

Страница 79: ...5 the default username is adtec and the default password is none for the administrator This password is stored differently than when in the ON mode and defaults to none regardless of previously changed passwords when set to the ON configuration The Login as Guest button may be used to view the Web UI in read only mode Web UI Authentication Advanced mode 79 ...

Страница 80: ...e read only or write Access by configuring the Write Access configuration to YES write or NO read only 6 De select tabs that are not desired to be viewed by the new user IE If the Security tab is grayed out the newly created user will not be able to navigate to the Security tab Sub tabs can also be chosen 7 Click Apply and share credentials with the desired user operator user1 without navigation c...

Страница 81: ...t If the port is changed the web address for login will need updated For example if the unit IP address is 192 168 10 48 standard web navigation can occur by typing http 192 168 10 48 in the browser address bar If the port is changed to 8000 for example then user would need to type http 192 168 10 48 8000 to navigate to the unit All requests on default HTTP port 80 would be denied Stealth IP addre...

Страница 82: ...ormation DVB S DVB S2 AUTO Modes The RD 71 with L Band demodulator LB option supports automatic detection of modulation type and symbol rate on two RF inputs In fully automatic mode the minimum configuration requirement is L Band frequency The demodulator is running in fully automatic mode when the type is set to AUTO and the symbol rate is set to 0 or AUTO Notes about demodulator Please note that...

Страница 83: ...he desired tuner After selection the profile will be previewed and all configuration fields will display the contents of the profile If the profile is desired to be loaded into the respective tuner click the Apply button If the profile is not desired the Cancel button may be clicked or the double dash profile may be selected to exit from preview mode Exiting preview mode will return to display the...

Страница 84: ...ticast unicast stream that is better to use than UDP in some environments RTP is built upon the building blocks of UDP but adds packet sequence identification Packet sequencing gives a receiver the information needed to detect and correct packets that were received out of order RTP is highly recommended when timely delivery of each consecutive packet may not be guaranteed The RD 71 supports up to ...

Страница 85: ...fers can be more forgiving with packet loss jitter and out of order packets The RD 71 supports up to 15Mb s when a 7 DVB Packet payload exists for each TCP packet Multicast is not supported with TCP streams The RD 71 supports both unicast point to point and multicast broadcast streams The RD 71 operates in UDP RTP mode by default To setup an IP Rx session first configure the IP Rx operation mode A...

Страница 86: ...for any streams sent directly to it Refer to your IP transmitter documentation for proper configuration of the transmitter Unicast Multicast Reception Enter the port number in the port field The port number must match the port number used on the transmitter where the range is 0 to 65535 When 0 multicast is disabled If you are new to multicast and attempting a first time connection 2000 is a common...

Страница 87: ...tal decoding An audio pass through consists of a Dolby E 20 Bit Dolby E 16 Bit Dolby Digital or a Linear PCM stream that is preserved not decoded from the transport stream and embedded on the SDI output Mpeg 1 Layer 2 decode support includes 48kHz 32 384kbps Interoperability support includes stream type 0x03 sometimes called Mpeg 1 Layer 2 stream type 0x04 sometimes called Mpeg 2 Layer 2 PES align...

Страница 88: ... the Audio tab for users that need to select custom PID s disable audios and duplicate audio pairs Dolby E line placement is handled automatically to meet Dolby Labs specification Some users may need custom line placement If the customer Dolby E line placement selection is out of specification the RD will revert line placement to the automatic in range value Please see table in notes for Dolby E l...

Страница 89: ...080 p 50 720p 50 525 29 97 1080i 59 94 1080p 59 94 720p 59 94 Earliest 8 13 26 17 12 18 35 23 Ideal 80us 11 19 37 25 13 21 42 28 Ideal 80us 12 21 42 28 14 24 47 32 Ideal 80us 13 23 103 31 16 26 52 35 Latest 30 53 105 70 26 48 95 63 Adtec Auto 19 30 42 35 19 30 47 40 89 ...

Страница 90: ... within the video elementary stream as SEI data H264 or user data MPEG2 The RD 71 does not support AFD via an ANC PID at this time The RD 71 AFD implementation preserves the native AFD code from the video elementary stream and is inserted into the SDI ancillary data output on DID SDID 0x4105 The SDI output is not modified in anyway based upon this data SDI line number for AFD carriage is configura...

Страница 91: ... clock This mode allows two RD 71 s to be used for receiving 3D 4K signals or when the decoded source is using the same clock base as the SYNC IN This mode bypasses the need for the audio sample rate converters Genlock REMOTE mode is used when the SYNC IN signal does not use the same 27 MHz clock source as the decoded stream This mode enables the audio sample rate converters for audio output The S...

Страница 92: ... wants to preserve encryption on the ASI output but also wants to decode one of the incoming programs This configuration also allows the RD to ingest encrypted MPTS streams that may be over the TSO limit A sample diagram of how the transport stream is passed to the ASI output through the system is shown below If the user wants to use the IRD as a decoder and decrypter the TS Out Decrypt configurat...

Страница 93: ...ts in the transport stream such as tables data or the audio for a specific program Program Service Channel A combination of one or more elements video audio or data defined by a PMT Summary Service Filtering allows an MPTS from the input to be turned into an SPTS or program reduced MPTS on a given output This is helpful in service turn around applications where all programs are not desired for re ...

Страница 94: ...can be sourced from ASI IN RF1 IN or RF2 IN depending on demodulator hardware option Then choose the ASI Output behavior or ASI Output TMR ASI Output TMR determines the ASI egress rate When set to AUTO the default the output rate will be the sum of all filter PIDs configured for the output minimal NULL stuffing When set to NATIVE the output TMR is set to match the INPUT source TMR MANUAL is a user...

Страница 95: ... download the firmware file from our website and store it locally Login to the web based application and navigate to the Upgrade Firmware tab Click on the upload button located at the top right of the application Select the firmware file from your local machine and wait for it to upload Once it has finished uploading it will appear in the Available Versions list 95 ...

Страница 96: ...uct firmware update and should be planned during maintenance windows Adtec currently has several demodulator versions that include ADV LB and PRM models Each demodulator hardware type has a unique demod firmware version and must be upgraded with a compatible version To upgrade first determine the installed demodulator type and firmware version Visit the Upgrade Features tab The BOARDS INFO table s...

Страница 97: ...e Available Demodulator Versions list The time required to update firmware varies on hardware model and should be accounted for during the maintenance windows Estimated Time required to update firmware LB Demod firmware update 6 minutes Once the version is seen on the Upgrade Firmware tab click SELECT to start the upgrade process A status bar will appear and will progress as the firmware update co...

Страница 98: ...ware upgrade fails for any reason it is OK Just try the upgrade again by clicking on the SELECT button The upgraded version can be verified by visiting the Upgrade Features tab after reboot It is recommended to delete the file after a successful upgrade by clicking the DELETE button 98 ...

Страница 99: ...esentative If a temporary key is required the Temporary ID will also be required Permanent Key Instructions A permanent unlock key can be provided via email or verbally if internet access is not available To enter the unlock key Step Action 1 Click on the Input Key button next to the desired feature 2 Enter the supplied key into the pop up dialog box and click OK 3 The feature status should change...

Страница 100: ...Step Action 1 Download the temporary key file to your computer provided by your representative 2 Click on the Upload button in the top right hand corner of the Web UI 3 Browse for the supplied ASC file from the file browser pop up and click Open 4 The page should reload and feature status should change from DISABLED to ENABLED with a Days Left count This count determines how many days the key will...

Страница 101: ...101 ...

Страница 102: ...Rx mode the IRD is acting as a client and can therefore bypass the need for firewall forwarding rules to the IRD In this mode all Zixi parameters are configured on the receiver or RD 71 Zixi uses a combination of FEC and ARQ to deliver packets The amount of latency between end points the amount of packet loss incurred between end points and the bandwidth requirements of the link all affect how the...

Страница 103: ... first found radio button next to IP If all settings are correct then the Zixi stream should appear and start decoding Setting up Zixi Rx To use Zixi Rx the feature key must be enabled This may be verified on the Upgrade Features tab If the key is not enabled please contact your sales representative sales adtecinc com Select ZIXI Rx under IP Rx Mode The Web interface will prompt for a reboot confi...

Страница 104: ...77 Input the appropriate settings in the Zixi Receiver section The channel name shall match the Broadcasters Stream ID and Client ID should match the Broadcasters Remote ID Via the Input RD Services tab select the Select first found radio button next to IP If all settings are correct then the Zixi stream should appear and start decoding 104 ...

Страница 105: ...et the source code And you must show them these terms so they know their rights We protect your rights with two steps 1 copyright the software and 2 offer you this license which gives you legal permission to copy distribute and or modify the software Also for each author s protection and ours we want to make certain that everyone understands that there is no warranty for this free software If the ...

Страница 106: ...the same sections as part of a whole which is a work based on the Program the distribution of the whole must be on the terms of this License whose permissions for other licensees extend to the entire whole and thus to each and every part regardless of who wrote it Thus it is not the intent of this section to claim rights or contest your rights to work written entirely by you rather the intent is t...

Страница 107: ...ticular circumstance the balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances It is not the purpose of this section to induce you to infringe any patents or other property right claims or to contest validity of any such claims this section has the sole purpose of protecting the integrity of the free software distribution system which is...

Страница 108: ...istribute it and or modify it under the terms of the GNU General Public License as published by the Free Software Foundation either version 2 of the License or at your option any later version This program is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU General Public Lic...

Страница 109: ...109 ...

Страница 110: ...l Four Female F connectors 75 Ohm PRX model Sync Input Use Auto detects Bi Level and Tri level sync for Genlock 3D and Ultra HD applications Connector BNC 75 Ohm Outputs 3G SDI HD SDI SD SDI Two banks two mirrored SDI outputs per bank of SDI Outputs from Decoder Standard Video Audio SMPTE 259M SD SMPTE 292M HD SMPTE 424M 3G Up to 16 Channels of Embedded audio SDI Ancillary support for Closed Capti...

Страница 111: ...capability x4 simultaneous MPEG over IP transport streams Connector 2x RJ45 Communications COM2 Serial Port Use API Serial Communication Interface Default Baud Configuration 38 400bps 8 data bits 1 stop bit no parity Connector 8 pin RJ45 COM1 Serial Port Use Serial Port Used for Troubleshooting Terminal Connector 8 pin RJ45 supplied with DB9 to RJ45 adapter Baud Configuration 115 200 bps 8 data bi...

Страница 112: ... except ASO FMO Audio Decode MPEG 1 Layer 2 audio 8 pairs Dolby Digital AC3 stereo downmix 8 pairs requires feature key AAC LC stereo requires feature key AAC 6 0 Surround Decode AAC LC requires feature key Audio Pass through Supports up to two Dolby E 16 20 bit Dolby Digital AC3 16 bit and or Linear PCM 16 20 24 bit pass through sessions 24 bit input samples are truncated to 20 bits Each SDI outp...

Страница 113: ...5 2 3 3 4 5 6 8 9 9 10 DVB S2 16APSK 2 3 3 4 4 5 5 6 8 9 9 10 DVB S2 32APSK 3 4 4 5 5 6 8 9 9 10 DVB S symbol rate range Up to 62Msym s DVB S2 symbol rate range 1 65Msym s QPSK 8PSK 16APSK 32APSK frequency range 950 2150MHz min input level 65dBm max input level 25dBm LNB Power and Control 13V vertical polarisation 18V horizontal polarisation 22kHz band selection according to universal LNB for ASTR...

Страница 114: ... 15 32 45 DVB S2X 8APSK 4 9 L 26 45 L DVB S2X 8PSK 23 36 25 36 13 18 7 15 8 15 26 45 32 45 DVB S2X 16APSK 1 2 L 8 15 L 5 9 L 26 45 3 5 3 5 L 28 45 23 36 2 3 L 25 36 13 18 7 9 77 90 7 15 8 15 26 45 3 5 32 45 DVB S2X 32APSK 2 3 L 32 45 11 15 7 9 2 3 32 45 DVB S2X 64APSK 32 45 L 11 15 7 9 4 5 5 6 DVB S symbol rate range 1 45Msym s DVB S2 X symbol rate range 1 60Msym s QPSK 8PSK 16APSK 32APSK 64APSK f...

Страница 115: ...Appendix C Adtec Digital Support Service For Customer Service contact information SLA Information policies and more please visit the support site at http www adtecdigital com support 115 ...

Страница 116: ...the top and sides of the unit is at least one half inch one centimeter Mounting of the unit in a rack should be such that no hazardous condition is achieved due to uneven mechanical loading Use only a grounded electrical outlet when connecting the unit to a power source Reliable earth grounding of rack mount equipment should be maintained Particular attention should be given to supply connection o...

Страница 117: ...e la classe B répond à toutes les exigences de l interférence canadienne causant des règlements d équipement L opération est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interférence nocive et 2 ce dispositif doit accepter n importe quelle interférence reçue y compris l interférence qui peut causer l opération peu désirée European Union EMC Directive Conformance State...

Страница 118: ...um or machine readable form without prior written consent from Adtec Digital Trademarks RD 71 is a trademark of Adtec Digital Dolby Dolby Digital AC 3 and the double D symbol are registered trademarks of Dolby Laboratories Other product and company names may be trademarks or registered trademarks of their respective companies The information in this document is subject to change without notice 118...

Отзывы: