![adstec OPC7000 Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/adstec/opc7000-series/opc7000-series_instruction-manual_2853866034.webp)
OPC7000 series
33
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
5 Commissioning
The interfaces for the device are located under protective covers. It has to be removed in order to
connect the power supply lead and the interface cables.
All supply leads and all required data leads have to be connected before commissioning.
ATTENTION
The device must be switched off before
connecting or disconnecting any cables in order
to prevent damage to the electronics!
The device may only be switched on after
acclimatising to the ambient temperature in order
to avoid condensate accumulation. Make sure to
meet the permissible voltage for this device.
After switching off and before switching on you
must wait for at least 5 seconds.
Information:
The shielding of a data cable must always be connected with the connector housing
(EMC).
For embedded operating systems, the interfaces must be explicitly enabled
and the necessary drivers installed in order to use them.