![Adp HED Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/adp/hed-series/hed-series_installation-instructions-manual_2853418009.webp)
CONDENSATE DRAIN THROUGH TEE PIPE AND DRAIN LOOP
Venting may be single−wall (26
GSG) galvanized or equivalent
stainless steel vent pipe sealed
per these instructions, OR
listed special vent for Category
III appliances.
SLOPE = 1/4 IN. PER
FOOT RUN MAXIMUM.
NOTE − Minimum horizontal
length equals 5 feet (1.53 m).
This does not include termination
tee. Refer to table 6 for maximum
length and number of elbows.
DOWNWARD SLOPE ON HORIZONTAL VENT
TEE PIPE
SECTION
DRAIN LOOP WITH
WATER TRAP TO
CONDENSATE TRAP
(Provided by installer)
12 INCHES
(30.5 cm)
MINIMUM
VENT TERMINATION
TEE OR 90° ELBOW
FIGURE 5
CONDENSATE DRAIN THROUGH VENT TERMINATION
DOWNWARD SLOPE ON HORIZONTAL VENT
Venting may be single−wall (26
GSG) galvanized or equivalent
stainless steel vent pipe sealed
per these instructions, OR
listed special vent for Category
III appliances.
SLOPE = 1/4 IN. PER
FOOT RUN MAXIMUM.
NOTE − Minimum horizontal
length equals 5 feet (1.53 m).
This does not include termination
tee. Refer to table 6 for maximum
length and number of elbows.
12 INCHES
(30.5 cm)
MINIMUM
DOUBLE
MALE
VENT TERMINATION
ADAPTER
TEE
(Cat III kits
only)
FIGURE 6
TABLE 5
Category III Horizontal Venting Components
(Required for Horizontal Vent Applications)
Unit
Part Number
Description
66808902
4" upward sloped Cat III vent kit
HED−75
66809002
4" downward sloped Cat III vent kit
HED−100
66809102
4" 90° elbow Cat III (required)
HED−125
66809301
4" straight pipe (length = 6")
HED−150
66809302
4" straight pipe (length = 12")
66809303
4" straight pipe (length = 36")
66808903
5" upward sloped Cat III vent kit
HED−200
66809003
5" downward sloped Cat III vent kit
66809103
5" 90° elbow Cat III (required)
HED−250
66809401
5" straight pipe (length = 6")
HED−300
66809402
5" straight pipe (length = 12")
66809403
5" straight pipe (length = 36")