FLUE PASSAGEWAY AND FLUE BOX

 

 

The  flue  passages  and  flue  box  should  be  inspected 

and  cleaned  prior  to  each  heating  season.  The 

sequence of operation should be as follows:

 

 

1 −  Turn off both electrical and gas supply to unit. 

 

2 −  Disconnect combustion air inducer wiring.

 

 

3 −  Remove screws securing flue box to unit. Remove 

flue  box.  If  necessary,  remove  blower  assembly 

from flue box. Clean flue box with wire brush.

 

 

4−  On  HED-100,  -125,  -150,  -200,  -250,  and  -300 

models,  remove  turbulator  retention  bracket  and 

turbulators.  Clean  turbulators  with  wire  brush. 

There are no turbulators on HED-75 duct heaters.

 

 

5 −  Remove burners as described in Burners" section.

 

 

6 −  Clean tubes with a wire brush.

 

 

7 −  Reassemble unit. The combustion air and flue box 

gaskets  should  also  be  replaced  during 

reassembly.

 

 

8 −  Restore  electrical  power  and  gas  supply.  Follow 

lighting  instructions  to  light  unit.  Check  operation 

of unit.

 

 

COMBUSTION AIR INDUCER

 

 

Under normal operating conditions, the combustion air 

inducer  should  be  checked  and  cleaned  prior  to  the 

heating  season  with  the  power  supply  disconnected. 

Use a small brush to clean inducer wheel.

 

 

ELECTRICAL

 

 

1 −  Check all wiring for loose connections.

 

 

2 −  Check for correct voltage at unit (unit operating).

 

 

3 −  Check amperage draw.

 

 

FLUE AND CHIMNEY

 

 

Check all vent and vent connector joints for tightness.

 

 

Ensure that connections are sealed and that there are 

no blockages.

 

FAILURE TO OPERATE

 

 

If unit fails to operate check the following:

 

 

1 −  Is thermostat calling for heat?

 

 

2 −  Is main disconnect closed?

 

 

3 −  Is there a breaker tripped or a fuse blown?

 

 

4 −  Is gas turned on at meter?

 

 

5 −  Is manual shutoff valve open?

 

 

6 −  Is unit ignition system in lock out? If unit locks out 

again, call service technician to inspect unit.

 

 

7 −  Is  pressure  switch  closed?  Obstructed  flue  will 

cause unit to shut off at pressure switch. Check 

flue passage and outlet.

 

 

SAFETY SHUT−OFF VALVE TEST

 

 

The safety shut−off valve test procedure is as follows:

 

 

1 −  Turn off the manual gas valve.

 

 

2 −  Set the thermostat to call for heat.

 

 

3 −  System begins normal sequence of operation.

 

 

4 −  After  approximately  30  seconds  (pre  purge 

period) the LED will fast flash indicating the gas 

valve is powered.

 

 

5 −  After 10 seconds, the gas valve closes and steps 

4  and  5  will  repeat  two  additional  times  before 

locking out the gas valve, which will be indicated 

by two flashes on the LED.

 

 

6 −  To restart the system, de-energize the thermostat 

call for heat and follow the operating instructions 

under Unit Start−Up".

 

 

REPAIR PARTS

 

 

When  ordering  repair  parts  include  the  complete  unit 

model  number  listed  on  the  unit  rating  plate.  For 

example: HED−175A−1.

 

 

 

 

15

Содержание HED Series

Страница 1: ...mplate 17 Warranty 18 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exact ly could result in serious injury death or property damage Be sure to read and understand the installation operation and service instructions in this manual Improper installation adjustment alter ation service or maintenance can cause serious injury death or...

Страница 2: ... in 31 5 16 32 3 16 41 1 8 3 11 16 40 17 1 2 3 1 4 25 39 1 8 15 3 8 35 1 16 9 HED 250 A S mm 795 817 1045 97 1016 445 83 635 994 391 891 229 HED 300 A S A Heat Exchanger Aluminum Steel S Heat Exchanger Stainless Steel Shipping The heater is completely assembled and is shipped with installation and operating instructions warranty certificate and flue transition Check the unit for shipping damage Th...

Страница 3: ...e area clearance from the heater to combustible materials must be such that the combustible material must not attain a temperature above 160 F 71 C during continuous operation of the unit WARNING These units are CSA international design certified These duct heaters are certified for clearances to combustible material as listed in table 1 and on unit rating plate Accessibility and service clearance...

Страница 4: ...onnection and not less than 2 equivalent diameters in length See figure 1 SINGLE BLOWER APPLICATION Top View 155 TRANSITION HED UNIT BLOWER AIR FLOW DUCT LENGTH L The formula for computing duct length L is 4WH W WidthH Height Inlet W H Duct length L is computed as shown by the formula and rounded to the nearest whole number MODEL INLET DUCT in mm DUCT NO WIDTH HEIGHT LENGTH L HED 75 15 13 3 8 29 3...

Страница 5: ... rotate the combustion air inducer on HED models 200 250 and 300 Rotate the combustion air inducer assembly as follows 1 Remove the heater from the carton Decide the best duct heater orientation The vent can be installed in one of three discharge positions up left or right 2 If the inducer is to be rotated follow the instructions in this section otherwise refer to instructions under Venting sectio...

Страница 6: ...l HED duct heaters are listed as Category 1 appliances for vertical vent installations 1 All HED duct heaters are to be used with NFPA or ANSI approved chimneys or U L listed type B 1 gas vents where applicable as well as the modifications and limitations listed in figure 2 Seal single wall vent material according to General Recommendations and Requirements section 2 Keep the vent connector runs a...

Страница 7: ...ct heater If the HED duct heater is to be horizontally vented a positive pressure may be created in the vent The duct heater when installed with horizontal venting will perform as a category III appliance 1 Special vent materials approved for use with Category III appliances may be used with these units Refer to table 7 for venting components 2 If possible do not terminate the horizontal vent thro...

Страница 8: ...he vent termination if permitted by authorities Fig 5 13 For horizontal venting the vent pipe must be supported with hangers no more than 3 feet 1m apart to prevent movement after installation 14 All horizontal vent applications which use Category III vent pipe must terminate with an approved Category III tee Opening end must face downward 15 When termination is routed through an exterior combusti...

Страница 9: ...ructions OR listed special vent for Category III appliances SLOPE 1 4 IN PER FOOT RUN MAXIMUM NOTE Minimum horizontal length equals 5 feet 1 53 m This does not include termination tee Refer to table 6 for maximum length and number of elbows 12 INCHES 30 5 cm MINIMUM DOUBLE MALE VENT TERMINATION ADAPTER TEE Cat III kits only FIGURE 6 TABLE 5 Category III Horizontal Venting Components Required for H...

Страница 10: ...fused disconnect switch with the fuse sized according to blower motor size Connect wiring through knockout on the junction box located on the side of the duct heater Refer to heater wiring diagram for connection information Use 18 gauge wire or larger for thermostat connections NOTE Electrically ground unit in accordance with local codes or in the absence of local codes in accordance with the curr...

Страница 11: ...hese devices should be properly labeled by the installer GAS SUPPLY TO UNIT HEATER MANUAL MAIN SHUT OFF DISCONNECT GAS VALVE WILL NOT HOLD NORMAL TEST VALVE WHEN TEST PRESSURES OF 1 2 psig PRESSURES OF 1 2 psig 3 45kPa 3 45kPa OR HIGHER OR HIGHER WILL BE USED CAP UNIT HEATER FIGURE 8 Unit Start Up FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Electric shock hazard Can cause injury or death Do not u...

Страница 12: ...ttempt to light the burners manually 5 Honeywell VR8205 series turn manual knob on gas valve clockwise to OFF Do not force For White Rodgers 36 series gas valve move lever to OFF 6 Wait five minutes to clear out any gas If you then smell gas STOP Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you do not smell gas go to next step 7 Honeywell VR8...

Страница 13: ...ximately centered in the tubes with no apparent impingement taking place 7 The ignition control will energize the ACC terminals approximately 45 seconds after ignition is established 8 After the thermostat demand is satisfied the gas valve is closed Five seconds after the demand is satisfied the combustion air inducer is shut off 9 The ignition control will de energize the ACC terminals approximat...

Страница 14: ...e switch is factory set and no field adjustment is necessary Service LUBRICATION Combustion air inducer motor bearings are pre lubricated and sealed No further lubrication is necessary BURNERS 1 Periodically examine burner flames for proper appearance during the heating season 2 Before each heating season examine the burners for any deposits or blockage that may have occurred 3 Clean burners as fo...

Страница 15: ...nit unit operating 3 Check amperage draw FLUE AND CHIMNEY Check all vent and vent connector joints for tightness Ensure that connections are sealed and that there are no blockages FAILURE TO OPERATE If unit fails to operate check the following 1 Is thermostat calling for heat 2 Is main disconnect closed 3 Is there a breaker tripped or a fuse blown 4 Is gas turned on at meter 5 Is manual shutoff va...

Страница 16: ...l No Serial No Service Technician Electrical Connections Tight Air Shutters Properly Adjusted If Installed Supply Voltage Flue Connections Tight Blower Motor Lubrication O K Gas Piping Connections Tight Leak Tested THERMOSTAT Furnace Btu Input Calibrated Heat Anticipator Properly Set Line Pressure Manifold Pressure w c Level 16 ...

Страница 17: ...TEMPLATE Location of Combustion Air Inducer Mounting Holes for Rotated Inducer EXISTING HOLE EXISTING HOLE EXISTING HOLE 17 ...

Страница 18: ... credit in the amount of the heat exchanger original selling price toward the purchase of a new ADP unit heater No extended coverage granted for HED series heat exchangers For information on this product s warranty including accessing complete warranty terms registering for an extended warranty or obtaining instructions on filing a warranty claim please go to www ADPwarranty com In such states or ...

Страница 19: ...19 ...

Страница 20: ......

Отзывы: