ADOS S.R.L. Buccinasco (MI)
417-MTA200I1
Rev. 9
Page 23 of 77
2.11 Batch
mode
The instrument can automatically load 1, 2 or 3 components (double speed) and unload one
component (dual speed) based on used defined data.
Each component is defined by the following parameters:
•
Set
This is the weight of the component to dose.
•
Slowdown
This is the weight value to be dosed in “slow” mode.
•
Fly
This is the weight value for the component “in fly”.
•
Tolerance
This is the allowable tolerance value on the weight of the dosed component.
Common batch parameters are:
•
Stabilisation time
This is the wait time between the de-activation of the component
command and the dosed weight control.
•
Wait time
This is the wait time before switching to the next component.
•
Maximum Load
This is the maximum allowable material on balance.
•
Zero Band
This is the value of load on balance to consider the balance empty.