background image

32 

 Product / Warranty Service 

Warranty Policy 

Thank you for choosing ADLINK. To understand your rights and enjoy all 
the after-sales services we offer, please read the following carefully. 

1.  Before using ADLINK’s products please read the user manual and 

follow the instructions exactly. When sending in damaged products 
for repair, please attach an RMA application form which can be 
downloaded from: http://rma.adlinktech.com/policy/. 

2.  All ADLINK products come with a limited two-year warranty, one 

year for products bought in China. 

 

The warranty period starts on the day the product is shipped 
from ADLINK’s factory.   

  Peripherals and third-party products not manufactured by 

ADLINK will be covered by the original manufacturers' 
warranty.  

  For products containing storage devices (hard drives, flash 

cards, etc.), please back up your data before sending them for 
repair. ADLINK is not responsible for any loss of data.   

 

Please ensure the use of properly licensed software with our 
systems. ADLINK does not condone the use of pirated 
software and will not service systems using such software. 
ADLINK will not be held legally responsible for products 
shipped with unlicensed software installed by the user.   

  For general repairs, please do not include peripheral 

accessories. If peripherals need to be included, be certain to 
specify which items you sent on the RMA Request & 
Confirmation Form. ADLINK is not responsible for items not 
listed on the RMA Request & Confirmation Form. 

3.  Our repair service is not covered by ADLINK's guarantee in the 

following situations: 

  Damage caused by not following instructions in the User's 

Manual.  

  Damage caused by carelessness on the user's part during 

product transportation.   

  Damage caused by fire, earthquakes, floods, lightening, 

pollution, other acts of God, and/or incorrect usage of voltage 
transformers.  

Содержание USBDAQ-9100MS

Страница 1: ...USBDAQ 9100MS Universal Serial Bus Multi Functions Data Acquisition Module User s Guide Recycled Paper...

Страница 2: ......

Страница 3: ...ages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright Al...

Страница 4: ...pc adlink com tw NuPRO nupro adlink com tw Software sw adlink com tw TEL 886 2 82265877 FAX 886 2 82265717 Address 9F No 166 Jian Yi Road Chungho City Taipei 235 Taiwan Please inform or FAX us of your...

Страница 5: ...r 12 2 3 Check USBDAQ 9100MS for Properly Installation 15 Chapter 3 Signal Connections 16 3 1 Digital Input Output Pin Assignment 17 3 2 Isolated Digital Input and Digital Output Connection 21 3 3 Gen...

Страница 6: ...ii Table of Contents Warranty Policy 32...

Страница 7: ...time display of acquired data while eliminating the need for expensive memory in the acquisition device USBDAQ 9100MS 100kS s multifunction I O USB module delivers high performance and reliable data a...

Страница 8: ...p to 500kS s AD sampling rate Up to 100kS s Continuous AD sampling 4 channels enabled 800Kbyte sec USB throughput rate system dependent Programmable inputs range Refer to section 1 3 for details Two 1...

Страница 9: ...Introduction 3 1 2 Applications Automatic test equipment Industry process monitoring and control Manufacture automation Portable Measurement Laboratory Equipment...

Страница 10: ...nnels simultaneous sample Simultaneous sample channels CH1 CH3 CH5 CH7 and CH2 CH4 CH6 CH8 Resolution 12 bit Max Sampling Rate 500KS s Simultaneous Sampling 100KS s Multiplex Sampling Input Range Prog...

Страница 11: ...r Output Coupling DC Protection Short circuit to ground Output Impedance 0 1 min Output Driving 5mA max Power On State Offline Data Transfer Program Control Trigger Pattern Generate Isolation Digital...

Страница 12: ...Timer Channels 2 Width 16 bit Compatibility 5V TTL Base Clock 8 4 2 1MHz Programmable Data Transfer Program Control LED Indicator Power On Orange Light Device found and driver Installed Red Light Ope...

Страница 13: ...Temperature 0 to 55 C Storage Temperature 20 to 70 C Relative Humidity 5 to 95 non condensing Software Support USBDAQ Utility for setup acquisition real time display DLL driver for Visual Basic Delph...

Страница 14: ...contains sensitive electronic components that can be easily damaged by static electricity Inspect the card module carton for obvious damage Shipping and handling may cause damage to your module Be sur...

Страница 15: ...llowing items USBDAQ 9100MS multifunction I O USB module Driver CD ROM USB Cable Type A to Type B AIO Signal Probe Stand Arm If any of these items is missing or damaged contact the dealer from whom yo...

Страница 16: ...running Green A application Program is running ON OFF Power Push Button Analog Input CH1 to CH8 RCA differential analog input channel Analog Output CH1 to CH2 RCA single end bipolar analog output Digi...

Страница 17: ...your computer Note 1 DC Jack 12V DC adapter Note 2 Power Jack The Power Connector to Power Supply Note 2 Note 1 The front and rear USB connector should be used only one at the same time 2 DC Jack and...

Страница 18: ...efore Plug USBDAQ 9100MS You should install driver first 1 Run Setup exe in the driver folder You should see the screen like this Press Next 2 Choose the destination folder Default folder is C Program...

Страница 19: ...tion is done Plug USBDAQ 9100MS and Push the power button You should see the LED lightup in orange color After found new hardware notify please redirect the driver to where you install The Windows wil...

Страница 20: ...14 Installation LED Status Note Power On Orange Light Device found and driver Installed Red Light Operation Green Light...

Страница 21: ...Installation 15 2 3 Check USBDAQ 9100MS for Properly Installation After the driver installation is done you can plug USBDAQ 9100MS and push the Power Button Now you can use USBDAQ 9100MS...

Страница 22: ...ignal Connections 3 Signal Connections This chapter describes the connector of USBDAQ 9100MS also the signal connection between USBDAQ 9100MS and external devices such as daughter boards or other devi...

Страница 23: ...ed 46 NC Not Connected 13 NC Not Connected 47 NC Not Connected 14 NC Not Connected 48 NC Not Connected 15 NC Not Connected 49 NC Not Connected 16 NC Not Connected 50 NC Not Connected 17 NC Not Connect...

Страница 24: ...oard Digital Ground 34 NC Not Connected 68 NC Not Connected I O Type PWR Power Input Supply an external voltage source for Darlington Circuit TD62083AP Voltage Range to 24V This digital ground is also...

Страница 25: ...Output of Counter n GATEn 8254 Gate Input of Counter n TGIN External Digital Trigger Input Input trigger signal input Control the starting time of A D conversion Generic TTL 5V digital input There is...

Страница 26: ...20 Signal Connections DIN 68S View...

Страница 27: ...nection USBDAQ 9100MS provides 8 isolated digital input and 8 digital output channels on board Isolated Digital Input Isolated Digital Output PC 3H4 IDI_n DIGND 4 7K VCC 10K DC Up to 24V DC 5 35V VDD...

Страница 28: ...provides 2 8254 compatible Timer Counter and External Trigger Signal They are TTL level please DO NOT connect them the External Power Source 24V and isolated signals TTL Input Signals TTL Output Signa...

Страница 29: ...nalog Input Signal Connection USBDAQ 9100MS provides 8 differential analog input channels Their resolution is 12 bit Multiplexer Differential Input Programmable Amplifier AI1 AI2 ADC 1 AI3 AI4 ADC 2 A...

Страница 30: ...alog Output Signal Connection USBDAQ 9100MS provides 2 single end analog output channels Its output is fixed in 10V to 10V actually 9 995V in 12 bit resolution Vn A GND DAC 1 A A Out2 Out1 Load Vn A G...

Страница 31: ...eorem of the functions on USBDAQ 9100MS module is described in this chapter The functions include the A D conversion Digital I O and General Purpose Counter Timer The operation theorem can help you to...

Страница 32: ...sly and after the first bank of data is converted it will start to scan the other bank of data Any one of the channels in the Bank can be enabled or disabled and if all the channels in the Bank are di...

Страница 33: ...base SCIC 16 bit Register for specify the time between Bank One scan and Bank Two Scan Specify the data Sampling Interval SCIC_counter Timebase SC 16 bit Specify the number of scans after trigger Afte...

Страница 34: ...t data to D A converter And with Continuous Mode the output data are stored in the D A output FIFO memory and data update frequency is defined by the parameter UpdateRate in software driver Data can b...

Страница 35: ...Here is just a brief description There are six modes in the standard 8254 mode 0 to mode 5 Mode 0 Interrupt on terminal count In this mode the output goes low after the mode set operation and the cou...

Страница 36: ...Clock Gate Output 4 3 2 1 0 4 3 2 1 0 4 n 4 Mode 3 Square Wave Mode In this mode the output stays high for one half of the count clock pulses and stays low for the other half The following diagram sho...

Страница 37: ...etriggerable In this mode is similar to Software Trigger mode except that the gate input is used as a trigger to start counting The following diagram shows the timing diagram Clock Gate Output 4 3 2 1...

Страница 38: ...back up your data before sending them for repair ADLINK is not responsible for any loss of data Please ensure the use of properly licensed software with our systems ADLINK does not condone the use of...

Страница 39: ...ustomer user Damage from improper repair by unauthorized ADLINK technicians Products with altered and or damaged serial numbers are not entitled to our service This warranty is not transferable or ext...

Отзывы: