IMV ESD-BC4A Скачать руководство пользователя страница 1

IMV CORPORATION

 

SD Logger

  instruction manual[X519009-3] 

  1/28 

<2020/03/03> 

3

rd

 edition

 

 

SD

  Logger

4 

Instruction Manual 

ESD-CS4A 

ESD-CC4A 

ESD-BS4A 

ESD-BC4A

 

 
 
 
 
 

 
 

 
 

 

 

Cased (Case Type)

 

PCB

PCB Type

)】

 
 
 
 
 
 

 
 
 

 

The contents of this instruction manual are subject to change without notice for improvement. 

Please check our website for the latest information. 

 
 

Содержание ESD-BC4A

Страница 1: ...2020 03 03 3rd edition Logger Instruction Manual ESD CS4A ESD CC4A ESD BS4A ESD BC4A Cased Case Type PCB PCB Type The contents of this instruction manual are subject to change without notice for impr...

Страница 2: ...und 16 V File 17 1 File control system 17 2 Logging file script version 17 3 Subdirectory 17 4 Maximum number of files 18 5 Command version file specification Command version 18 6 Script file script v...

Страница 3: ...2020 03 03 3rd edition 6 Strengthen short term power off response 25 7 Other enhancements 26 8 Main differences from Logger 3 26 IX Functions enhanced after V394X 26 1 Script log start stop function...

Страница 4: ...e CMLogger provided by our company After confirming the operation on the personal computer it can be implemented in the SD logger script version Please refer to the following documents for the script...

Страница 5: ...on mode In the logger the setting can be changed in Configuration Mode The items that can be changed are as follows Item Contents Function Script version Command version Data bit 1 8 Bit 7 Bit Stop bi...

Страница 6: ...onnector Fixed screw Inch 4 40UNC Power supply DC 8V 12V Current consumption Standard 100mA maximum 150mA Operating temperature range 0 60 Time accuracy 0 01 Script WAIT TIME Built in clock accuracy W...

Страница 7: ...art PCB type No Symbol Contents SW2 Power switch CN3 Connector for memory card LED3 Red LED Error LED2 Yellow LED Access LED1 Green LED Pilot CN2 DC Power connector DC jack CN1 RS 232C Connector D Sub...

Страница 8: ...e No Symbol Contents POWER Power switch Connector for memory card ERR Red LED Error ACC Yellow LED Access PL Green LED Pirot DC8 12V DC power connector DC jack RS 232C RS 232C Connector D Sub pin male...

Страница 9: ...ration setting Configuration settings are made by connecting to a PC For configuration settings refer to Chapter I 3 For details refer to the way of using ESDHost X519006 Item Dip Switch Configuration...

Страница 10: ...mark Automatic clear of communication error Don t do Do Function Script version Command version Can be set Dip switch settings can be prioritized Can be set Cannot be set Default setting What has been...

Страница 11: ...is set by operating dip switches 1 to 3 The correspondence between switch ON OFF and bit rate is shown in the table below No Bit rate bps 1 2 3 4 5 6 7 8 OFF OFF OFF 9 600 ON OFF OFF 19 200 OFF ON OF...

Страница 12: ...Mode The mode is set by operating DIP switches 7 and 8 The correspondence between the switch ON and OFF and the mode is as shown in the table below No Mode 1 2 3 4 5 6 7 8 OFF OFF Normal ON OFF Config...

Страница 13: ...o pin 6 5 GND Signal ground 6 DSR Data set ready connected to pin 4 Note 1 7 RTS Transmission request usually high level Note 3 8 CTS Transmission permission not used note 4 9 Unused Note 2 Use a cros...

Страница 14: ...C power DC8V to 12V from the DC power connector DC jack CN2 for board Use a compatible DC plug with an inner diameter of 2 1 and an outer diameter of 5 5 When using an AC adapter select a suitable DC...

Страница 15: ...rns off the preparation is complete Procedure 3 Power switch POWER SW2 OFF To finish the work after receiving data and exchanging commands set the power switch to the OFF side Setting the power switch...

Страница 16: ...red ERR LED3 Flashes once The card is not installed Flashes twice Error in card access Flashes 3 times Data communication error Flashing In update mode The buzzer sounds as follows Buzzer When the acc...

Страница 17: ...a name that does not overlap with an existing file Search for the existence of the file from 0000 LOG to FFFF LOG and the name of the first non existent file found is used as the logging file name The...

Страница 18: ...e of the startup time for the number of files under certain conditions Number of files 512pcs 1 024pcs 4 096pcs 10 000pcs Start up time 1 3seconds 2 1 seconds 16 9 seconds 1minutes 29 6 seconds It is...

Страница 19: ...or use with large amounts of data In the command version check the response firmly it takes longer time to get a response Notes If it takes time to write 1 byte the power will not be turned off immedi...

Страница 20: ...ly is secured by the capacitor Even if the power supply main power supply to the DC power connector is cut off while the power switch is ON the power is supplied from the backup capacitor and the shut...

Страница 21: ...witch can be turned ON OFF via the CN1 D sub connector Jumper shorting External power control terminal J1 1 CN1 D Sub No 1 pin J1 2 CN1 D Sub No 6 pin The board switches on at 2 5 to 15V and switches...

Страница 22: ...SD Logger instruction manual X519009 3 22 28 2020 03 03 3rd edition Picture of jumper switches and power switches J2 J1 1 J1 2 J3 SW2...

Страница 23: ...tes Script version Command version Receive buffer capacity 4096 4096 RTS ON threshold 768 768 RTS OFF threshold 512 512 Conflict with script function Even if flow control is enabled RTS control in the...

Страница 24: ...iewing it with an editor Status file File name STATUS TXT Folder Root folder Status file format Item Example Name Version DT MC04 V400 Start up time 2018 02 15 12 57 34 Model script Communication sett...

Страница 25: ...ate module file will be renamed to UPDATE OK You only need to update once and the same update will not be repeated 4 Synchronize script and incoming data In MC04 the execution of the script and the lo...

Страница 26: ...een changed to be done in configuration mode FATSYS conventional FAT16 file system has been abolished and now only FatFs FAT32 compatible file system FatFs FAT32 compatible file system can also use FA...

Страница 27: ...SD Logger instruction manual X519009 3 27 28 2020 03 03 3rd edition External dimensions Case type Weight about 163 PCB type Weight about 65...

Страница 28: ...eriod 1 Due to incorrect use 2 Incorrect connection 3 Due to wrong power supply 4 Modified or repaired by the customer 5 Fire earthquake storm and flood damage lightning and other natural disasters po...