Operation Theory
35
Trigger Modes
Software-Trigger Acquisition
This trigger mode does not require any external trigger source.
The trigger event occurs when the _9812_AD_DMA_Start( )
function is called to start the operation.
Post-Trigger Acquisition
Use post-trigger acquisition in applications where data needs
to be collected after a specified trigger event. The trigger can
either be an external analog trigger or digital trigger.
Figure 5-1: Post-Trigger Acquisition
Pre-Trigger Acquisition
Use pre-trigger acquisition to collect data before a specified
trigger event. The trigger can either be an external analog
trigger or digital trigger.
The data acquisition starts when DMA operation starts. The
operation stops when the external trigger event occurs. If the
external trigger occurs before the specified count of data is
read (specified by the _9812_AD_DMA_Start( ) function,
please refer to section 6.2), the amount of retrieved data would
be less than the specified count. However if the external trigger
occurs after the specified count of data is read, the program
only samples the specified count of data.