20
•
Installation
Figure 2.14 Gate source of counter #1 ~#4
The jumper setting is flexible for users‘ applicati ons. There are two
configurations: jumper installed or NOT installed. The default state
of jumper is not installed and the counter can be controlled externally
or just pull-high enable. When the jumper installed, the gate is
cascaded from counter #6 outp ut and the
ExtG n
signal is an output
signal.
Note that the external gate source must NOT be used when
cascaded gate source is used. The Table 2.5 shows the reference
number of the gate control jumpers and its corresponding
counter/timer channels number. The default setting of every jumper
is also shown.
Jumper
Label
Gate source of
counter/timer
Default gate
source
G1
GATE1
ExtG1
G2
GATE2
ExtG2
G3
GATE3
ExtG3
G4
GATE4
ExtG4
Table 2.5 Reference number of clock setting jumpers
2.11 Counter Outputs
The timer/counter output signals (
COUT n
) of 8254 are controlled by
clock source, gate control and software programming. All the output
of the 8 independent counters are sent to the 37 pins connector
directly. The
COUT6
and
COUT12
of the two pairs of cascaded
counters are also send to connector. Therefore, totally 10 counter
outputs are sent to connector, see 'Pin assignment' for
corresponding signal pin number.
In addition, the output signal may be used as clock source or gate
control of the cascaded counters, see the above sections. It is
possible to cascaded two counters by jumpers. The counters output
COUT6
,
COUT12
are also used as internal interrupt source (refers
to 'Interrupt System').
Содержание NuDAQ ACL-8454
Страница 1: ...N u D A Q ACL 8454 MultiFunctions Counter Timer Card User s Guide...
Страница 2: ......
Страница 5: ......
Страница 6: ......
Страница 10: ......
Страница 23: ...Installation 13 reference number of chips and the counters number...
Страница 39: ...Registers Format 29 Bit 7 6 5 4 3 2 1 0 Base 5 DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0...