134

Digital Input/Output Function Library

GPO_Write

This API is used to write the new state of a digital output (DO):

     

char GPO_Write(UCHAR GpioNum,UCHAR GpioPortVal)

Arguments:

     

GpioNum

: The number of a digital output pin (4-7).

     

GpioPortVal

: A new output state 0 or 1.

Return values:

     

GPIO_OK

 on success. 

GPIO_ERROR

 on failure.

RegisterInterruptEvent

The event passed will be signaled when there is a change in
state on a digital input pin. This API is used to register the
event.

     char RegisterInterruptEvent(HANDLE Event, UCHAR Pin)

Argument:

     

Event

: Handle of the event that wait for Interrupt notification.

     

Pin

: The number of an input pin.

Return values:

     

GPIO_OK

 on success. 

GPIO_ERROR

 on failure.

Содержание DLAP-3200-CF Series

Страница 1: ... 3200 CF Series Embedded System supporting MXM Graphics Module with 8th 9th Generation Intel Core i7 i5 i3 in LGA1151 Socket User s Manual Manual Rev 1 0 Revision Date August 13 2021 Part No 50M 00004 1000 ...

Страница 2: ...ii Revision History Revision Release Date Description of Change s 1 0 2021 08 13 Initial release ...

Страница 3: ...of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsi bility to global environmental preservation through compliance with the European Union s Restriction of Hazardous Substances RoHS directive and Waste Electrical and Electronic Equipment WEEE directive Environm...

Страница 4: ...e companies Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly NOTE NOTE Additional information aids and tips that help users perform tasks CAUTION Information to prevent minor physical injury component dam age data loss and or program corruption when trying to com plete a task ATTENTION Information...

Страница 5: ...2 2 DLAP 3200 CF Functional Block Diagram 8 2 3 Display Options 9 2 4 Mechanical Dimensions 10 3 System Layout 15 3 1 Front Panel 15 3 2 Internal I O Connectors 23 4 Getting Started 45 4 1 Installing 2 5 Storage 46 4 2 Installing an M 2 Module 48 4 3 Installing MXM P1000 P2000 T1000 Module 63 4 4 Installing MXM P3000 P5000 RTX3000 RTX5000 Module 67 4 5 Installing a PCIe x4 Add on Card 73 4 6 Mount...

Страница 6: ...Ie Interrupt Routing Mapping 93 B 8 SMBus Slave Address Mapping 94 C Appendix BIOS Setup 95 C 1 BIOS Setup Menu 95 C 2 Menu Structure 97 C 3 Main Menu 99 C 4 Advanced Menu 102 C 5 Chipset 120 C 6 Security 127 C 7 Boot 128 C 8 Save Exit 129 D Appendix DisplayPort BIOS Settings 131 D 1 MXM P1000 P2000 T1000 RTX3000 RTX5000 131 D 2 MXM P3000 P5000 132 E Appendix Digital Input Output Function Library ...

Страница 7: ...ble 3 10 SATA Connector Pin Definition 29 Table 3 11 COM Connector Pin Definition 30 Table 3 12 CPU System Fan Connector Pin Definition 31 Table 3 13 GPU Fan Connector Pin Definition 32 Table 3 14 Audio Connector Pin Definition 33 Table 3 15 COM1 RS 232 CCtalk Selection Jumper 34 Table 3 16 Case Open Jumper 34 Table 3 17 ME Lock Jumper 34 Table 3 18 Clear CMOS Jumper 35 Table 3 19 BIOS WP Jumper 3...

Страница 8: ...viii List of Tables This page intentionally left blank ...

Страница 9: ...ion 22 Figure 3 8 Mainboard Connectors Top 23 Figure 3 9 Mainboard Connectors Rear 24 Figure 3 10 USB 2 0 Connector Pin Definition 27 Figure 3 11 USB 3 2 Connector Pin Definition 28 Figure 3 12 PCIe Power Connector Pin Definition 29 Figure 3 13 SATAConnector Pin Definition 29 Figure 3 14 COM Connector Pin Definition 30 Figure 3 15 CPU System Fan Connector Pin Definition 31 Figure 3 16 GPU Fan Conn...

Страница 10: ...x List of Figures This page intentionally left blank ...

Страница 11: ... for full height half length add on card support 1 2 Features X ADLINK MXM Graphics module support Type A B B up to 120W X 8th 9th Gen Intel Core i7 i5 i3 Celeron processors X Dual SODIMMs for up to 64GB DDR4 non ECC memory CPU dependent X 6x DisplayPort 2 from CPU 4 from MXM X 1x M 2 E key supporting 1630 or 2230 for Wi Fi Bluetooth module X 1x M 2 B key supporting 2242 or 2280 for SATA storage m...

Страница 12: ...ms are included in the package X 1x DLAP 3200 CF Embedded Computer X Fasteners Z 3x M3 screws P head L4 Ni for M 2 P N 33 03013 0040 Z 8x M3 screws F head L4 Nylok for 2 5 storage bay P N 33 03103 1040 Z 2x M3 screws I head L4 Nylok for MXM P N 33 03306 0040 NOTE NOTE If the DLAP 3200 CF does not have a pre installed MXM P3000 P5000 RTX3000 RTX5000 the following additional installation items have ...

Страница 13: ...00 P5000 P N 32 20823 0020 A0 X MXM cooler for T1000 P N 32 20830 0200 A0 X MXM cooler for RTX3000 P N 32 20823 1100 A0 X MXM cooler for RTX5000 P N 32 20839 1000 A0 X 12V 240W power adaptor P N 31 62164 0010 A0 X DLAP 3000 AC DC power supply kit 500W 12V 41 7A P N 91 95296 002E X Wall mount bracket set P N 34 34546 0000 A0 2 required X Wi Fi Kit Intel Wireless AC 9260 non vPRO P N 91 95266 0020 ...

Страница 14: ...4 Introduction This page intentionally left blank ...

Страница 15: ...Hz support 6C 6T X Intel Core i3 9100E 3 1GHz 6M Cache 65W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i3 9100TE 2 2GHz 6M Cache 35W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i7 8700 3 2GHz 12M Cache 65W TDP LGA1151 DDR4 2666MHz support 6C 12T X Intel Core i7 8700T 2 4GHz 12M Cache 35W TDP LGA1151 DDR4 2666MHz support 6C 12T X Intel Core i5 8500 3 0GHz 9M Cache 65W TDP LGA1151 DD...

Страница 16: ... and 5V 2A Storage SATA X 2x 2 5 SATA 6Gb s external drive bays X 2x SATA 6Gb s signals via M 2 M B key connectors X Intel RST RAID Support Physical Dimensions 235 x 182 x 129mm W x D x H without foot pads Mounting Optional wall mount bracket Power Supply DC Input DC 12V input Molex DC in jack AC Input X Optional 240W 12V 20A AC DC adapter X Optional 500W 12V 41 7A AC DC power supply unit Environm...

Страница 17: ...MC EN55032 35 EN61000 6 2 4 CE FCC Part 15B Class B w 240W adaptor Class A w 500W PSU Safety UL cUL and CB NOTE NOTE X Models marked with do not include an MXM graphics module X Contact your local ADLINK sales representative for MXM module and related DLAP model longevity Model DLAP 3200 CFP1 DLAP 3200 CFP2 DLAP 3200 CFT1 DLAP 3200 CFT3 DLAP 3200 CFT5 DLAP 3200 CFP3 DLAP 3200 CFP5 DLAP 3200 CFP12 ...

Страница 18: ...12A_Diodes M 2_B_key CNx1 2280 size default LAN4 i210_Intel DP CN LVDS CN DP CN SODIMM 2 DDR4 non ECC Socket SODIMM 1 DDR4 non ECC Socket LPC bus MXM3 1 slot p54 Port A Port B Port C Port D DP CN DP CN HDMI CN DMI USB3 Gen1x1 4 RJ45 x1 CN 2 2 2 2 USB3 Gen1x1 USB2 0 LAN HDA Line In Mic In USB2 0 Speaker Out USB3 Gen1x1 PCIex1 USB2 0 PCIex1 SATA USB2 0 PCIex1 2 USB2 0 ADM213EA_ADI UART UART System F...

Страница 19: ...t time to properly access the display settings in the BIOS menu Refer to Appendix D Display Port BIOS Settings for more information Table 2 1 Maximum Display Resolution Port Resolution Display Port 1 from CPU DP 1 4096x2304 60Hz Display Port 2 from CPU DP 2 4096x2304 60Hz Display Port A from MXM DP A Based on MXM module Display Port B from MXM DP B Based on MXM module Display Port C from MXM DP C ...

Страница 20: ...ications 2 4 Mechanical Dimensions Figure 2 2 DLAP 3200 CF Front View including wall mount brackets and footpads NOTE NOTE All dimensions are in millimeters unless noted 235 00 129 00 132 96 235 00 129 00 137 00 ...

Страница 21: ...Specifications 11 DLAP 3200 CF Figure 2 3 DLAP 3200 CF Left Side View 194 50 182 00 ...

Страница 22: ...12 Specifications Figure 2 4 DLAP 3200 CF Right Side View 194 50 182 00 ...

Страница 23: ...Specifications 13 DLAP 3200 CF Figure 2 5 DLAP 3200 CF Rear View 235 00 ...

Страница 24: ...ature limits if the airflow through the vents is restricted AVERTISSEMENT Pour éviter d endommager le système assurez vous qu il y a un dégagement minimum de 10 cm aut our des bouches d aération pour une circulation d air sans restriction La température de l air à l intérieur du boîtier peut dépasser les limites de température de fonctionnement spéci fiées si le flux d air à travers les évents est...

Страница 25: ...System Layout 15 DLAP 3200 CF 3 System Layout 3 1 Front Panel The DLAP 3200 CF Series provides the following I O access fea tures Figure 3 1 DLAP 3200 CF Front Panel I O A B C E F H J I M L D G F G K ...

Страница 26: ...16 System Layout Figure 3 2 DLAP 3200 CF Rear Panel I O P N O ...

Страница 27: ...22 485 for COM2 K 2x PCIe x4 Gen3 slots D DisplayPort x2 DP 1 DP 2 L 2x 2 5 hot swappable storage bay Bay 1 Bay 2 E i210 AT LAN 2 LAN 3 M Power on module See 3 1 1 Power on Module F i210 AT LAN 4 USB 3 2 Gen1 x1 Type A U3 U4 N DIO G i219 LM LAN 1 USB 3 2 Gen1 x1 Type A U1 U2 O Speaker out Left and Right Mic in Optional Audio hole is sealed when not available H DisplayPort from MXM for DP A DP B P ...

Страница 28: ...ights blue when the system is powered on blinks when the system suspends to RAM and is off when the system suspends to disk M4 Remote Power On Button Connector Remote power on control Note Requires additional cable with an ALEX 9566 02G tin plated connector The left pin is GND and the right pin is PRWBTN short enabled MPN ALEX 9553 02 PBT black M5 Temperature Alarm LED Blinks white when CPU or GPU...

Страница 29: ...channel Digital Output X Output type Open drain N channel X MOSFET driver with internal pull high of 200Ω resistance X Source Sink current for all channels 22mA X VOH 4 956 to 5V X VOL 0 to 0 085V Figure 3 4 Digital I O Connector Pin Definition Table 3 2 Digital Input Output Connector Pin Definition Pin Signal Pin Signal Pin Signal 1 DI0 6 VCC 5V standby is always on except when in ACPI S5 11 DO0 ...

Страница 30: ...20 System Layout Figure 3 5 Digital Input Circuit Figure 3 6 Digital Output Circuit D G Nȍ Nȍ S 2 2 D G S 220 2 2K ...

Страница 31: ...dicators Table 3 4 Speed LED Indicators LED Color Status Description Orange Off Ethernet port is disconnected On Ethernet port is connected with no activity Flashing Ethernet port is connected and active LED Color Status Description Green Orange Off 10 Mbps Green 100 Mbps Orange 1000 Mbps ...

Страница 32: ...232 422 485 modes by BIOS setting while COM1 supports only RS 232 Figure 3 7 COM Port Pin Definition Table 3 5 D Sub 9 pin Signal Function of COM Ports Pin Signal Name RS 232 RS 422 RS 485 1 DCD TXD422 485DATA 2 RXD TXD422 485DATA 3 TXD RXD422 N S 4 DTR RXD422 N S 5 GND N S N S 6 DSR N S N S 7 RTS N S N S 8 CTS N S N S 9 RI N S N S 1 5 6 9 ...

Страница 33: ...d on devices must be carried out by ADLINK service personnel only Users must not disassemble the device themselves L installation de périphériques complémentaires doit être effec tuée uniquement par le personnel de service ADLINK Les util isateurs ne doivent pas démonter l appareil eux mêmes D E C B J K F G H I M N L O P Q T A S U V AC AB AA Z Y X W AH AI ...

Страница 34: ...C DRAM socket for DIMM2 D CPU Fan connector E System Fan connector F 2x USB 2 0 Gen1 x1 pin header for U9 U14 G RS 232 pin header for COM1 H RS 232 422 485 pin header for COM2 I 2x USB 3 2 Gen1 x1 pin header for U5 U6 J Multi I O connector K Audio pin header L PCIe power connector AD AE AF AG ...

Страница 35: ...y connector V GPU fan connector W 12V DC in connector X DisplayPort C and D from MXM Y DisplayPort A and B from MXM Z LAN 1 and USB 3 2 Gen 1 x1 ports 1 and 2 AA LAN 4 and USB 3 2 Gen 1 x1 ports 3 and 4 AB LAN 2 and LAN 3 AC DisplayPort 1 and 2 from CPU AD DB40 connector AE M 2_B Key connector AF M 2_M Key connector DLAP 3100 CF and DLAP 3200 CF AG M 2_E Key connector AH Blue LED2_BMC status AI RE...

Страница 36: ...e Power Up failures can indicate a corrupted BIOS or failure of the onboard power supply A blink code displays in cases of failure When the system is in an S3 state the Status LED flashes every four seconds 3 2 2 2 WDT LED Red The WDT LED is driven by SEMA and will light when a watchdog timeout occurs It stays on until it is cleared by software or the reset button LED Blink Code Status 0 NOERROR 2...

Страница 37: ...is provided on the mainboard for an inter nal USB dongle Figure 3 10 USB 2 0 Connector Pin Definition Table 3 7 USB 2 0 Connector Pin Definition Pin Signal Pin Signal 1 P5V_USB1 6 CN_U2_USB14_P 2 P5V_USB1 7 GND 3 CN_U2_USB9_N 8 GND 4 CN_U2_USB14_N 9 NC 5 CN_U2_USB9_P 10 GND 1 10 ...

Страница 38: ...ctor Pin Definition Table 3 8 USB 3 2 Connector Pin Definition Pin Signal Pin Signal 1 NC 11 P5V_USB56 2 CN_U3_USB6_T_P 12 CN_U2_USB5_N 3 CN_U3_USB6_T_N 13 CN_U2_USB5_P 4 GND 14 GND 5 CN_U3_USB6_R_P 15 CN_U3_USB5_R_N 6 CN_U3_USB6_R_N 16 CN_U3_USB5_R_P 7 GND 17 GND 8 CN_U2_USB6_P 18 CN_U3_USB5_T_N 9 CN_U2_USB6_N 19 CN_U3_USB5_T_P 10 P5V_USB56 20 NC 1 20 ...

Страница 39: ...Pin Definition Table 3 9 PCIe Power Connector Pin Definition 3 2 6 SATA Power Connector Figure 3 13 SATAConnector Pin Definition Table 3 10 SATA Connector Pin Definition Pin Signal 1 P_ 12V_S 2 P_ 12V_S 3 P_ 5V0_S 4 P_ 5V0_S 5 GND Pin Signal 1 P_ 5V0_S 2 P_ 5V0_S 3 P_ 5V0_S 4 GND 5 GND 6 GND ...

Страница 40: ...gure 3 14 COM Connector Pin Definition Table 3 11 COM Connector Pin Definition Pin Signal Name RS 232 RS 422 RS 485 1 DCD Tx Tx Rx 2 DSR Tx Tx Rx 3 RxD Rx N A 4 RTS Rx N A 5 TxD N A N A 6 CTS N A N A 7 DTR N A N A 8 RI N A N A 9 GND GND GND ...

Страница 41: ...PU System Fan Connectors Two connectors are provided for CPU and system fan power Figure 3 15 CPU System Fan Connector Pin Definition Table 3 12 CPU System Fan Connector Pin Definition Pin Signal 1 FAN_GND 2 P_ 12V_FAN 3 FAN_IN 4 FAN_OUT 1 ...

Страница 42: ...32 System Layout 3 2 9 GPU Fan Connector Figure 3 16 GPU Fan Connector Pin Definition Table 3 13 GPU Fan Connector Pin Definition Pin Signal 1 FAN_OUT 2 FAN_IN 3 P_ 12V_FAN 4 FAN_GND ...

Страница 43: ... 10 Audio Connector Figure 3 17 Audio Connector Pin Definition Table 3 14 Audio Connector Pin Definition Pin Signal Pin Signal 1 AUDIO_Sense 6 GND_AUD 2 SPK_RP 7 A_MIC_IN_L 3 A_L_IN_L 8 SPK_LP 4 SPK_RN 9 A_MIC_IN_R 5 A_L_IN_R 10 SPK_LN ...

Страница 44: ...lk Selection Jumper Table 3 15 COM1 RS 232 CCtalk Selection Jumper 3 2 11 2 Case Open Jumper Table 3 16 Case Open Jumper 3 2 11 3 ME Lock Jumper Table 3 17 ME Lock Jumper RS 232 CCtalk 1 3 RS 232 default 2 4 7 9 8 10 3 5 CCtalk 4 6 9 11 10 12 Case open 13 14 Function ON N A Undo default ME Lock 15 16 Lock N A Undo default ...

Страница 45: ... BIOS WP 19 20 BIOS WP N A Undo default NOTE NOTE X S3 and S4 not supported under operating system X IAMT is not supported while pairing with Q370 X BIOS ME version information is shown as zero X Do not install an operating system when BIOS WP is enabled X Intel GbE LAN cannot update the MAC address X A special PN process is needed if the default setting is Write Protect Enabled ...

Страница 46: ...tor Pin Definition Table 3 20 Power on Module Connector Pin Definition Pin Signal Pin Signal 1 P_ 5V0_A 9 LED_TEMP_ALARM 2 P_ 3V3_A 10 GND 3 PWR_BTN 11 LED_FAN_ALARM 4 LED_STANDBY 12 GND 5 RST_BTN 13 P_ 12V_A 6 POWER_ON 14 GND 7 RESET_BUTTON_ALARM 15 BEEP_TEMP_ALARM 8 PCH_SATS L 16 GND ...

Страница 47: ...tem Layout 37 DLAP 3200 CF 3 2 13 DIO Connector Figure 3 20 DIO Connector Pin Definition Table 3 21 DIO Connector Pin Definition Pin Signal 1 5V_12V_S 2 GND 3 DI0 4 DI1 5 DI2 6 DI3 7 DO0 8 DO1 9 DO2 10 DO3 ...

Страница 48: ...G Before providing DC power ensure the voltage and polarity provided are compatible with the DC input Improper input volt age and or polarity can be responsible for system damage AVERTISSEMENT Avant de fournir une alimentation CC assurez vous que la tension et la polarité fournies sont com pati bles avec l entrée CC Une tension d entrée et ou une polarité incorrectes peuvent être responsables de d...

Страница 49: ...n Signal A1 Pin 1 on bottom GND A2 P_ 12V_S A3 P_ 12V_S A4 GND A5 JTAGE_CLK NC A6 JTAGE_DI NC A7 JTAGE_DO NC A8 JTAGE_MS NC A9 P_ 3V3_S A10 P_ 3V3_S A11 PCH_PLTRST L_BUF A12 GND A13 CLKOUT_PCIE_P7 A14 CLKOUT_PCIE_N7 A15 GND A16 GF_PCIEX21_RX_P A17 GF_PCIEX21_RX_N A18 GND A19 NC A20 GND A21 GF_PCIEX22_RX_P ...

Страница 50: ...F_PCIEX24_RX_N A31 GND A32 NC A33 NC A34 GND A35 GF_PCIEX1_RX_P A36 GF_PCIEX1_RX_N A37 GND A38 GND A39 GF_PCIEX2_RX_P A40 GF_PCIEX2_RX_N A41 GND A42 GND A43 GF_PCIEX3_RX_P A44 GF_PCIEX3_RX_N A45 GND A46 GND A47 GF_PCIEX4_RX_P A48 GF_PCIEX4_RX_N A49 GND B1 Pin 1 on top P_ 12V_S B2 P_ 12V_S B3 P_ 12V_S B4 GND B5 PCH_SMB_CLK_A Pin Signal ...

Страница 51: ...15 GF_PCIEX5_21_TX_N B16 GND B17 PCH_CLK_REQ7 L B18 GND B19 GF_PCIEX22_TX_P B20 GF_PCIEX22_TX_N B21 GND B22 GND B23 GF_PCIEX23_TX_P B24 GF_PCIEX23_TX_N B25 GND B26 GND B27 GF_PCIEX24_TX_P B28 GF_PCIEX24_TX_N B29 GND B30 NC B31 PCH_CLK_REQ7 L B32 GND B33 GF_PCIEX1_TX_P B34 GF_PCIEX1_TX_N B35 GND B36 GND B37 GF_PCIEX2_TX_P B38 GF_PCIEX2_TX_N Pin Signal ...

Страница 52: ...tor Pin Definition B39 GND B40 GND B41 GF_PCIEX3_TX_P B42 GF_PCIEX3_TX_N B43 GND B44 GND B45 GF_PCIEX4_TX_P B46 GF_PCIEX4_TX_N B47 GND B48 PCH_CLK_REQ7 L B49 GND Pin Signal 1 VCC_SPI_IN 2 GND 3 SPI_BIOS_CS0 4 SPI_BIOS_CS1 5 SPI_BIOS_MISO 6 SPI_BIOS_MOSI 7 SPI_BIOS_CLK 8 3V3_LPC 9 GND 10 BIOS_DIS0 Pin Signal ...

Страница 53: ...FRAME 14 LPC_AD3 15 LPC_AD2 16 LPC_AD1 17 LPC_AD0 18 3 3V_SMC 19 3 3V_A 20 GND 21 TXD6 22 RXD6 23 FUMD0 24 RESET_IN 25 DATA 26 CLK 27 OCD0A 28 OCD0B 29 PWRBTN 30 SYS_RESET 31 CB_RESET 32 CB_PWROK 33 SUS_S3 34 SUS_S4 35 SUS_S5 36 POSTWDT_DIS 37 SEL_BIOS 38 BIOS_MODE 39 SMC_STATUS 40 RESVD Pin Signal ...

Страница 54: ...44 System Layout This page intentionally left blank ...

Страница 55: ...isassemble the device themselves Avertissement L installation d une carte d extension PCIe doit être effectuée uniquement par le personnel de service ADLINK Les utilisateurs ne doivent pas démonter l appareil eux mêmes CAUTION Disconnect the unit from power before opening the chassis or installing any internal components See Important Safety Instructions on page 135 ATTENTION Débranchez l unité de...

Страница 56: ...46 Getting Started 4 1 Installing 2 5 Storage Before installing a disk drive the drive bracket must be removed 1 Remove the thumbscrews and take out the 2 5 drive bay ...

Страница 57: ...up to 9mm thick into the bracket and use the 4 provided M3 screws at 4kgf cm torque to attach the drive to the bracket 3 Gently slide the bracket back into the drive bay until the SATA connector on the PCB is engaged and then refas ten the thumbscrews ...

Страница 58: ... Installing an M 2 Module Remove the bottom panel before installing an M 2 Module 1 Remove 10 screws total to release the bottom panel from the chassis 4 on the bottom 2 on the left side and 4 on the right side Bottom screws ...

Страница 59: ...Getting Started 49 DLAP 3200 CF Left side screws ...

Страница 60: ...50 Getting Started Right side screws ...

Страница 61: ...Getting Started 51 DLAP 3200 CF 2 Apply the minimum amount of pressure necessary to slide the panels apart in the directions shown to reveal the internal contents of the unit ...

Страница 62: ...52 Getting Started 3 Remove the 4 screws attaching the left drive bay to the chassis ...

Страница 63: ... Wi Fi Kit Intel Wireless AC 9260 non vPRO P N 91 95266 0020 Z M 2 M key module example M 2 PCIe Gen3 x4 SSD 128G PS5012 E12 M 2 2280 P N 95 31102 4310 Z M 2 B key module example 4G Module EM06 A Kit M 2 B Key with Antenna P N 91 95284 000E A 4G mod ule needs to be used with the DLAP 3200 CF with an eSIM SKU Contact an ADLINK sales representative for more information E key M key B key ...

Страница 64: ...e antenna cables of the M 2 B key and E key modules are installed as shown in the figures below For improved cable management route the M 2 B key cables under the drive bay support plate before making the antenna connections ...

Страница 65: ...Getting Started 55 DLAP 3200 CF Make sure the antenna wires are properly soldered to the M 2 B key and E key modules B key line out E key line out ...

Страница 66: ...56 Getting Started 6 The figure below shows the locations of the M 2 B key and E key module antenna cable connections B key B key E key E key ...

Страница 67: ...Getting Started 57 DLAP 3200 CF 7 Attach the antenna cable connectors and the drive bay screws at 6kgf cm torque B key B key E key E key ...

Страница 68: ...58 Getting Started 8 After reinstalling the left and right side covers fasten all the screws at 6kgf cm torque ...

Страница 69: ...Getting Started 59 DLAP 3200 CF Right side screws ...

Страница 70: ...60 Getting Started Left side screws ...

Страница 71: ...Getting Started 61 DLAP 3200 CF Bottom screws ...

Страница 72: ...62 Getting Started 9 Install and lock the antennas as shown B key E key B key E key B key E key ...

Страница 73: ...Getting Started 63 DLAP 3200 CF 4 3 Installing MXM P1000 P2000 T1000 Module 1 Remove the protective film from the MXM cooler ...

Страница 74: ...64 Getting Started 2 Attach the MXM cooler to the MXM module Tighten the screws in the order indicated at 4kgf cm torque ...

Страница 75: ...Getting Started 65 DLAP 3200 CF 3 Remove 2 screws to detach the top panel from the chas sis Remove the top panel to reveal the internal compo nents of the system ...

Страница 76: ...g Started 4 Attach the MXM module with 2 M3 screws P N 33 03306 0040 at 4kgf cm torque and plug the MXM cooling fan connector into the GPU fan connector 5 Screw the top panel back on to complete the installation ...

Страница 77: ...Getting Started 67 DLAP 3200 CF 4 4 Installing MXM P3000 P5000 RTX3000 RTX5000 Module 1 Remove 2 screws to detach the top panel from the chassis and reveal the internal components of the system ...

Страница 78: ...68 Getting Started 2 Remove the protective film from the MXM cooler bracket and attach the MXM bracket to the bottom side of the MXM module ...

Страница 79: ...Getting Started 69 DLAP 3200 CF 3 Attach the MXM module with 2 M3 screws P N 33 03306 0040 at 4kgf cm torque to the mainboard ...

Страница 80: ...0 Getting Started 4 Remove the protective film from the MXM cooler and lock the MXM cooler on the MXM module via the four spring screws Then plug the MXM cooling fan connector into the GPU fan connector ...

Страница 81: ...Getting Started 71 DLAP 3200 CF 5 Place 4 washers PN 33 90086 0000 A0 and 4 rubber spacers PN 39 00039 0000 over the screw holes on the top of the fan ...

Страница 82: ...72 Getting Started 6 Use 4 screws PN 33 03320 0050 to secure the rubber spacers to the fan at 4kgf cm torque 7 Screw the top panel back on at 6kgf cm torque to com plete the installation ...

Страница 83: ...Getting Started 73 DLAP 3200 CF 4 5 Installing a PCIe x4 Add on Card 1 Remove 2 screws to detach the top panel from the chassis ...

Страница 84: ...74 Getting Started 2 Remove the 2 screws attaching the fan bracket to the chassis and disconnect the fan cable ...

Страница 85: ...Getting Started 75 DLAP 3200 CF 3 Remove the 8 screws attaching the BM cover to the chassis ...

Страница 86: ...76 Getting Started 4 Remove the BM cover ...

Страница 87: ...Getting Started 77 DLAP 3200 CF 5 Remove the fan ...

Страница 88: ...78 Getting Started 6 Remove the 2 screws connecting the PCIe bracket 7 Remove the PCIe bracket ...

Страница 89: ...Getting Started 79 DLAP 3200 CF 8 Install a PCIe x4 add on card and tighten the lock screw at 6kgf cm torque 9 Reinstall the fan connect the fan power cable and tighten the screws at 6kgf cm torque ...

Страница 90: ...80 Getting Started 10 Attach the bottom cover and tighten the screws at 6kgf cm torque 11 Attach the BM and top covers and tighten the screws at 6kgf cm torque ...

Страница 91: ... Mounting 4 6 1 Install the Wall mount Brackets Use the 4 footpad screws to attach the 2 wall mount brackets to the chassis Utilisez les 4 incluses dans la boîte d accessoires pour fixer les 2 supports de montage mural inclus au châssis ...

Страница 92: ...rqued to 6kgf cm or the 6 mounting holes circled according to the spacing dimensions of the holes in the bracket as shown in Figure 2 6 DLAP 3200 CF Top View Montez l appareil sur un mur à l aide des 4 ouvertures de trou de serrure en fonction des dimensions d espacement des trous dans le support comme indiqué dans Figure 2 6 DLAP 3200 CF Top View ...

Страница 93: ...duct page at https www adlinktech com Products Industrial_PCs_Fanless_ Embedded_PCs IPCSystems DLAP 3200 CF_Series The following drivers must be installed X Intel GPU X Chipset X ME X LAN X Audio There are two different codec drivers Check the audio device after driver installation X MXM X DIO X RAID ...

Страница 94: ...84 Getting Started This page intentionally left blank ...

Страница 95: ...calculated as the product of applied voltage V and the current A Platforms tested for this data have available external I O inter faces and are attached to supported devices such as keyboard mouse USB dummy load COM loopback LAN port PCIe add on card and with an internal SSD driver installed NOTE NOTE Information in this Appendix is for power budget planning and design purposes only Actual power c...

Страница 96: ...5000 Full loading 335W 35W CPU RTX3000 Full loading 305W 35W CPU T1000 Full loading 275W 35W CPU P5000 Full loading 325W 35W CPU P3000 Full loading 300W 35W CPU P2000 Full loading 283W 35W CPU P1000 Full loading 272W NOTE NOTE X Sufficient power for the entire system is required to meet these specifications We recommend using a DC source instead of the optional 240W adaptor when power consumption ...

Страница 97: ...he size of the SPI ROM is 16MB for H310 and 32MB for Q370 chipsets From a software standpoint the serial peripheral interface SPI resides in the memory mapped space This function contains reg isters that allow for the setup and programming of devices that reside on the SPI interface The physical SPI ROM can be accessed by putting an address into the flash address register The motherboard SPI ROM m...

Страница 98: ...l Shared SRAM 0 0x15 0 Internal I2C Controller 0 0 0x15 1 Internal I2 C Controller 1 0 0x16 0 Internal HECI 1 0 0x17 0 Internal SATA Controller AHCI 0 0x1C 0 Internal PCI Express Root Port 1 0 0x1D 0 Internal PCI Express Root Port 9 0 0x1D 3 Internal PCI Express Root Port 12 0 0x1E 0 Internal UART 0 0 0x1F 0 Internal LPC Controller 0 0x1F 3 Internal Intel High Definition Audio Interface 0 0x1F 4 I...

Страница 99: ...errupt from slave PIC N A No 3 Serial Port 2 COM2 IRQ3 via SERIRQ PIRQ No 4 Serial Port 1 COM1 IRQ4 via SERIRQ PIRQ No 5 N A IRQ5 via SERIRQ PIRQ No 6 N A IRQ6 via SERIRQ PIRQ No 7 N A IRQ7 via SERIRQ PIRQ No 8 Real Time clock N A No 9 Generic N A No 10 N A IRQ10 via SERIRQ PIRQ No 11 N A IRQ11 via SERIRQ PIRQ No 12 N A IRQ12 via SERIRQ PIRQ No 13 Math Processor N A No 14 Generic N A No 15 N A N A...

Страница 100: ...2 IRQ3 via SERIRQ PIRQ See note 4 Serial Port 1 COM1 IRQ4 via SERIRQ PIRQ See note 5 N A IRQ5 via SERIRQ PIRQ See note 6 N A IRQ6 via SERIRQ PIRQ See note 7 N A IRQ7 via SERIRQ PIRQ See note 8 Real Time clock N A No 9 Generic N A No 10 N A IRQ10 via SERIRQ PIRQ See note 11 N A IRQ11 via SERIRQ PIRQ See note 12 N A IRQ12 via SERIRQ PIRQ No 13 Math Processor N A No 14 Generic N A No 15 N A N A See n...

Страница 101: ... Address Range Hex Size Description 4GB 2MB FFE00000 FFFFFFFF 2 MB High BIOS Area 4GB 18MB 4GB 17MB 1 FEE00000 FEEFFFFF 1 MB MSI Interrupt 4GB 20MB 4GB 19MB 1 FEC00000 FECFFFFF 1 MB APICConfiguration Space 15MB 16MB F00000 FFFFFF 1 MB ISA Hole 1MB 15MB 100000 EFFFFF 14 MB Main Memory 0K 1MB 00000 FFFFF 1 MB DOS Compatibility Memory ...

Страница 102: ... 092h Reset Bit 0 Fast Gate A20 Bit 1 0A0h 0B1h 0B4h 0BDh Interrupt Controller 2 8259 equivalent 0B2h and 0B3h APM control and status port 0E0h 0EFh Available 0F0h Co processor error register 2F8h 2FFh Serial Port 2 3F8h 3FFh Serial Port 1 378h 37Fh Available 380h 3AFh Available 4D0h Master PIC Edge Level Trigger register 4D1h Slave PIC Edge Level Trigger register 0A00h 0A2Fh Reserved for SIO func...

Страница 103: ...INTA 16 INTA 16 INTA 16 INTA 16 INTA 16 INTA 16 Int1 INTB 17 INTB 17 INTB 17 Int2 INTC 18 INTC 18 INTC 18 Int3 INTD 19 INTD 19 INTD 19 INT Line PCIe Port 1 PCIe Port 5 PCIe Port 6 PCIe Port 11 PCIe Port 17 PCIe Port 21 Int0 INTA 16 INTA 16 INTB 17 INTC 18 INTA 16 INTA 16 Int1 INTB 17 INTB 17 INTC 18 INTD 19 INTB 17 INTB 17 Int2 INTC 18 INTC 18 INTD 19 INTA 16 INTC 18 INTC 18 Int3 INTD 19 INTD 19 I...

Страница 104: ...94 Resource Mapping B 8 SMBus Slave Address Mapping The following table lists the SMBus slave address 8 bit address ing mapping Device Address DIMM A 0A0h DIMM B 0A4h BMC 050h NXP 0C0h ...

Страница 105: ...p Utility is invoked by pressing ESC or DEL when the system boots A system reboot is required when changes are made in the BIOS setup utility The BIOS Setup Utility includes the following hotkeys X F1 General help X F8 Load previous BIOS values X F9 Load BIOS default values X F10 Save Exit the setup utility Menu Selection Bar The Menu Selection Bar is located at the top of the screen It displays t...

Страница 106: ...d on a VT100 terminal connection via serial console with the following menu conventions X Using color The default BIOS setup fields are in black The BIOS setup fields currently not used are in grey The display strings are in black X Using brackets Editable menu options are marketed with square brackets and ...

Страница 107: ... the table Main Advanced BIOS Information System Information Processor Information Memory Information PCH Information Board Information System Date System Time Access level CPU Configuration Graphics Configuration Power Management System Management Thermal Management Watchdog Timer Super IO Configuration Serial Console Redirection Trusted Computing S5 RTC Wake Settings NVMe Configuration Network S...

Страница 108: ...t Boot Order Save Changes and Exit Discard Changes and Exit Save Changes and Reset Discard Changes and Reset Save Changes Discard Changes Restore Defaults Save as User Defaults Restore User Defaults Boot Override NOTE NOTE indicates a submenu Gray text indicates info only Bold text indicates a default setting ...

Страница 109: ...S Information Info only BIOS Vendor Info only BIOS Vendor BIOS Version Info only BIOS Version Build Date Info only BIOS build date MRC Version Info only MRC Version GOP Version Info only GOP Version ME FW Version Info only ME FW Version Feature Options Description System Information Info only Project Name Info only Project Name Feature Options Description CPU Board Version Info only CPU Board Vers...

Страница 110: ...H SKU Info only PCH SKU Stepping Info only PCH Stepping Feature Options Description Board Information Info only Serial Number Info only Serial Number Manufacturing Date Info only Manufacturing Date Last Repair Date Info only Last Repair Date MAC ID Info only MAC ID Feature Options Description Runtime Statistics Info only Total Runtime Info only Total Runtime Current Runtime Info only Current Runti...

Страница 111: ...day MM DD YYYY Requires the alpha numeric entry of the day of the week day of the month calendar month and all 4 digits of the year indicating the century and year Fri XX XX 20XX System Time HH MM SS Presented as a 24 hour clock setting in hours minutes and seconds Feature Options Description Access Level Administrator User ...

Страница 112: ...uction Cache Info only Displays the Processor L1 Instruction Cache size L2 Cache Info only Displays the Processor L2 Cache size L3 Cache Info only Displays the Processor L3 Cache size L4 Cache Info only Displays the Processor L4 eDRAM size VMX Info only VMX Supported or Not SMX TXT Info only SMX TXT Supported or Not Active Processor Cores All based on CPU SKU Number of cores to enable in each proc...

Страница 113: ...U Power Management Allows CPU to go to C states when not 100 utilized C State Auto Demotion Disabled C1 C3 C1 and C3 Configure C State Auto Demotion C State Un demotion Disabled C1 C3 C1 and C3 Configure C State Un demotion Package C State Demotion Disabled Enabled Package C State Demotion Package C State Un demotion Disabled Enabled Package C State Un demotion Package C State Limit C0 C1 C2 C3 C6...

Страница 114: ... Options Description Graphics Configuration Info only LVDS Info only eDP LVDS Disabled Enabled Enables Disables eDP LVDS LFP Panel Type VBIOS Default 640x480 800x600 1024x768 1280x1024 1400x1050 1266x768 1600x1200 1366x768 1680x1050 1920x1200 1440x900 1600x900 1024x768 1280x800 1920x1080 2048x1536 Select LFP panel used by Internal Graphics Device by selecting the appropriate setup item Spreading d...

Страница 115: ...acklight control function LVDS Backlight Brightness BMC Mode 0 255 Default 255 Set LVDS Backlight Brightness Percentage The change takes effect immediately GTT Mode 0 100 Default 100 Feature Options Description Power Management Info only Enable ACPI Auto Configuration Disabled Enabled Enables Disables BIOS ACPI Auto Configuration Enable Hibernation Disabled Enabled Enables Disables System ability ...

Страница 116: ... will turn off system power when shutdown NOTE AT mode will not support S3 S4 so it will change Power Loss State to Power On PCI Express Wake Disabled Enabled Enables Disables PCI Express Wake ping for PCIe device wake function Power Consumption Sub Menu Power Consumption Feature Options Description Power Consumption Info only Current Input Current Info only Current Input Current Current Input Pow...

Страница 117: ...IOS interface Feature Options Description SEMA Features Info only Uptime Power Cycles Counter Info only Uptime Power Cycles Counter System Restart Event Info only System Restart Event 1024 Bytes User Flash Info only 1024 Bytes User Flash Watchdog Info only Watchdog Temperatures Info only Temperatures Voltage Monitor Info only Voltage Monitor Display Backlight control Info only Display Backlight co...

Страница 118: ...Temperature Info only Board2 Temperature SEMA Error Log Info only SEMA Error Log Soft Fan Info only Soft Fan Feature Options Description Flags Info only BMC Flags Info only BMC Flags BIOS Select Info only BIOS Select ATX AT Mode Info only ATX AT Mode Exception Code Info only Exception Code Feature Options Description SPI ROM Write Protect Disabled Enabled Enables Disables SPI ROM Write Protect Fea...

Страница 119: ...y Min Board temperature Max Info only Max Board temperature GPU Temperatures Info only Current Info only Current GPU temperature Startup Info only Startup GPU temperature Min Info only Min GPU temperature Max Info only Max GPU temperature CPU Fan Speed Info only CPU Fan Speed System Fan Speed Info only System Fan Speed GPU Fan Speed Info only GPU Fan Speed Smart Fan Sub Menu Smart Fan Critical Tri...

Страница 120: ...t 30 PWM Level Trigger Point 2 Info only Trigger Temperature 0 100 Default 50 Trigger Temperature PWM Level 0 100 Default 65 PWM Level Trigger Point 3 Info only Trigger Temperature 0 100 Default 85 Trigger Temperature PWM Level 0 100 Default 80 PWM Level Trigger Point 4 Info only Trigger Temperature 0 100 Default 92 Trigger Temperature PWM Level 0 100 Default 100 PWM Level System Smart FanTemperat...

Страница 121: ...WM Level Trigger Point 4 Info only Trigger Temperature 0 100 Default 92 Trigger Temperature PWM Level 0 100 Default 100 PWM Level GPU Smart FanTemperature Source GPU Sensor GPU Smart FanTemperature Source GPU Fan Mode AUTO Smart Fan Fan Off Fan On GPU Fan Mode Trigger Point 1 Info only Trigger Temperature 0 100 Default 0 Trigger Temperature PWM Level 0 100 Default 25 PWM Level Trigger Point 2 Info...

Страница 122: ... resets the system after a certain amount of time after power up Timeout 0 65535 Default 65535 The time the Power Up Watchdog should wait until it resets the system ATTENTION Pressing F12 during start up disables the Power Up Watchdog Info only RunTime Watchdog Disabled Enabled The RunTime Watchdog resets the system after a certain amount of time after power up Timeout 0 65535 Default 24 The Power...

Страница 123: ...abled Enabled Disable Enable RI ping for Wake On Ring function PCH PME signal Feature Options Description Serial Console Redirection Info only COM1 Info only Console Redirection Disabled Enabled Enables Disables Console Redirection Console Redirection Settings Submenu The settings specify how the host computer and the remote computer will exchange data Both computers should have the same or compat...

Страница 124: ...both connected systems Long or noisy lines may require lower speeds Data Bits 7 8 Data Bits Parity None Even Odd Mark Space A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if num of 1 s in the data bits is odd Mark parity bit is always 1 Space Parity bit is always 0 Mark and Space Par...

Страница 125: ...y Support for ANSI VT100 terminals Recorder Mode Disabled Enabled With this mode enabled only text will be sent This is to capture Terminal data Resolution 100x31 Disabled Enabled Enables Disables extended terminal resolution Putty KeyPad VT100 LINUX XTERMR6 SCO ESCN VT400 Select FunctionKey and KeyPad on Putty Feature Options Description Configuration Info only Security Device Support Disabled En...

Страница 126: ... State of Security Device Platform Hierarchy Disabled Enabled Enables Disables Platform Hierarchy Storage Hierarchy Disabled Enabled Enables Disables Storage Hierarchy Endorsement Hierarchy Disabled Enabled Enables Disables Endorsement Hierarchy TPM2 0 UEFI Spec Version TCG_1_2 TCG_2 Select the TCG2 Spec Version Support Physical Presence Spec Version 1 2 1 3 Select to Tell OS to support PPI Spec V...

Страница 127: ...23 hr For example enter 3 for 3am and 15 for 3pm Wake up minute 0 59 Default 0 Range 0 59 min Wake up second 0 59 Default 0 Range 0 59 sec Wake up minute increase 1 5 Default 1 Range 1 5 min Feature Options Description NVMe Configuration Info only List NVMe Device Info only Feature Options Description Network Stack Disabled Enabled Enables Disables UEFI Network Stack Ipv4 PXE Support Disabled Enab...

Страница 128: ...conds to press ESC key to abort PXE boot Use either or numeric keys to set the value Media detect count 1 50 Default 1 Number of times the presence of media will be checked Use either or numeric keys to set the value Feature Options Description This sub menu is controlled by device firmware refer to the actual layout Feature Options Description Disk Memory Type Boot Service Data Reserved Specifies...

Страница 129: ...m file Feature Options Description Size Hex Number The valid RAM disk size should be multiples of the RAM disk block size Create Exit Yes Create a new RAM disk with the given starting and ending address Discard Exit Yes Discard and exit Feature Options Description Create from file Select file Create a RAM disk from a given file ...

Страница 130: ... Enabled VT d capability Above 4GB MMIO BIOS assignment Disabled Enabled Enables Disables above 4GB MemoryMappedIO BIOS assignment Feature Options Description Memory Configuration Info only Memory RC Version Info only Memory RC Version Memory Frequency Info only Memory Frequency Memory Timings tCL tRCD tRP tRAS Info only Memory Timings tCL tRCD tRP tRAS DIMM 1 Info only DIMM 1 info Size Info only ...

Страница 131: ...cs Configuration Info only Graphics Turbo IMON Current 14 31 Default 31 Graphics turbo IMON current values supported 14 31 Primary Display Auto IGFX PEG Select which of IGFX PEG Graphics device should be Primary Display Internal Graphics Auto Disabled Enabled Keep IGFX enabled based on the setup options GTT Size 2MB 4MB 8MB GTT Size DVMT Total Gfx Mem 128M 256M MAX DVMT5 0 Total Graphic Memory siz...

Страница 132: ...ng Disabled Enabled Allows disabling Spread Spectrum Clocking for compliance testing Feature Options Description PCH IO Configuration Info only PCI Express Configuration Sub Menu PCI Express Configuration settings SATA Configuration Sub Menu SATA Device Settings USB Configuration Sub Menu USB Configuration settings Security Configuration Sub Menu Security Configuration settings PCH digital I O dev...

Страница 133: ...PCI Express Configuration Info only PCI Express Clock Gating Disabled Enabled Enables Disables PCI Express Clock Gating for each root port Pcie Pll SSC Auto 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Pcie Pll SSC percentage AUTO Keep hw default no BIOS override Range is 0 0 2 0 ...

Страница 134: ...nfo only SATA device info Serial ATA Port 4 Info only SATA device info Feature Options Description USB Configuration Info only USB Overcurrent Disabled Enabled Select Disabled for pin based debug If pin based debug is enabled but USB overcurrent is not disabled USB DbC does not work USB Overcurrent Lock Disabled Enabled Select Enabled if Overcurrent functionality is used Enabling this will make xH...

Страница 135: ... Disabled Enabled U3_USB5_TX_P PIN HEADER USB Disabled Enabled U3_USB6_TX_P PIN HEADER USB Disabled Enabled U2_USB1_P EXTRENAL USB Disabled Enabled U2_USB2_P EXTRENAL USB Disabled Enabled U2_USB3_P EXTRENAL USB Disabled Enabled U2_USB4_P EXTRENAL USB Disabled Enabled U2_USB5_P PIN HEADER USB Disabled Enabled U2_USB6_P PIN HEADER USB Disabled Enabled U2_USB7_P M 2 Key_B Disabled Enabled U2_USB8_P M...

Страница 136: ...IO Configuration Security Config uration Feature Options Description Security Configuration Info only BIOS Lock Disabled Enabled Enables Disables the PCH BIOS Lock Enable feature Required to be enabled to ensure SMM protection of flash ...

Страница 137: ... User Audit Deployed Secure Boot Info only Active Not Active Vendor Keys Info only Valid Modified Secure Boot Control Disabled Enabled Secure Boot feature is Active if Secure Boot is Enabled Platform Key PK is enrolled and the System is in User mode Changing this requires a platform reset Secure Boot Mode Standard Custom Secure Boot mode options Standard or Custom In Custom mode Secure Boot Policy...

Страница 138: ... boot with initialization of a minimal set of devices required to launch active boot option Has no effect for BBS boot options Boot Configuration Info only Boot Option 1 Hard Disk CD DVD USB Hard Disk USB CD DVD USB Key USB Floppy USB Lan Network Disabled Hard Disk Sets the system boot order Boot Option 2 CD DVD Boot Option 3 USB Hard Disk Boot Option 4 USB CD DVD Boot Option 5 USB Key Boot Option...

Страница 139: ...m setup without saving any changes Save Options Info only Save Changes Yes No Saves changes done so far to any of the setup options Discard Changes Yes No Discards changes done so far to any of the setup options Restore Defaults Yes No Restores Loads default values for all the setup options Save as User Defaults Yes No Saves the changes done so far as User Defaults Restore User Defaults Yes No Res...

Страница 140: ...130 BIOS Setup This page intentionally left blank ...

Страница 141: ...ed Enabled No Yes No Yes Auto Enabled Enabled No Yes No Yes IGFX Disabled Enabled No No No Yes PEG Disabled Enabled No Yes No Yes Auto Disabled Enabled No Yes No Yes IGFX Auto Enabled Yes No Yes Yes PEG Auto Enabled No Yes No Yes Auto Auto Enabled No Yes No Yes IGFX Enabled Disabled Yes No Yes Yes PEG Enabled Disabled No Yes Yes Yes Auto Enabled Disabled No Yes Yes Yes IGFX Disabled Disabled No No...

Страница 142: ...d Enabled No Yes No Yes IGFX Auto Enabled Yes No Yes Yes PEG Auto Enabled No Yes No Yes Auto Auto Enabled No Yes No Yes IGFX Enabled Disabled Yes No Yes Yes PEG Enabled Disabled No Yes Yes Yes Auto Enabled Disabled No Yes Yes Yes IGFX Disabled Disabled No Yes No Yes PEG Disabled Disabled No Yes No Yes Auto Disabled Disabled No Yes No Yes IGFX Auto Disabled Yes No Yes Yes PEG Auto Disabled No Yes Y...

Страница 143: ...rial_PCs_Fanless_ Embedded_PCs IPCSystems DLAP 3200 CF_Series To use the DI O function library for the DLAP 3200 series include the header file GpioLib h and linkage library GpioLib lib in the C project DI O functions are as follows GPIO_Init This API checks if the GPIO driver handle is valid char GPIO_Init Return values GPIO_OK on success GPIO_ERROR on failure GPI_Read This API reads the digital ...

Страница 144: ...w output state 0 or 1 Return values GPIO_OK on success GPIO_ERROR on failure RegisterInterruptEvent The event passed will be signaled when there is a change in state on a digital input pin This API is used to register the event char RegisterInterruptEvent HANDLE Event UCHAR Pin Argument Event Handle of the event that wait for Interrupt notification Pin The number of an input pin Return values GPIO...

Страница 145: ...e with Article 645 of the National Electrical Code and NFPA 75 X To avoid electrical shock and or damage to device Z Keep device away from water or liquid sources Z Keep device away from high heat or humidity Z Keep device properly ventilated do not block or cover ventilation openings Z Always use recommended voltage and power source settings Z Always install and operate device near an easily acce...

Страница 146: ...power supply cord before loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up X It is recommended that the device be installed only in a server room or computer room where access is Z Restricted to qualified service personnel or users familiar with restrictions applied to the location reasons therefor and any precautions required Z Only affor...

Страница 147: ...alles de technologie de l information conformes à l article 645 du National Electrical Code et à la NFPA 75 X Pour éviter les chocs électriques et ou d endommager l appareil Z Tenez l appareil à l écart de toute source d eau ou de liq uide Z Tenez l appareil à l écart d une forte chaleur ou d une humidité élevée Z Maintenez l appareil correctement ventilé n obstruer ou ne couvrez pas les ouverture...

Страница 148: ...ne fonctionne pas ou ne fonctionne pas selon le manuel de l utilisateur X L appareil est tombé et ou a été endommagé et ou présente des signes évidents de dommage X Débranchez le cordon d alimentation avant de desserrer les vis à oreilles et serrez toujours les vis à oreilles avec un tourn evis avant de mettre le système en marche X Il est recommandé d installer l appareil uniquement dans une sall...

Страница 149: ...de Sécurité Importante 139 DLAP 3200 CF RISQUE DE BRÛLURES Partie chaude Ne touchez pas cette surface cela pourrait entraîner des blessures Pour éviter tout danger laissez la surface refroidir avant de la toucher ...

Страница 150: ...140 Consignes de Sécurité Importante This page intentionally left blank ...

Страница 151: ...408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology GmbH Hans Thoma Straße 11 D 68163 Mannheim Germany Tel 49 621 43214 0 Fax 49 621 43214 30 Email emea adlinktech ...