The battery charger is now in the stand-by mode with the default
choice of
Battery
-
“Gel Cell / SLA”
Current
– “2A DC Slow”
If the
Start Charging Button
is now pressed, the charger will
immediately go into the 2A DC, Gel Cell battery charging mode.
For alternative selection, please follow the following steps:
Step1
– Press the
Charge Rate Button
to pick the battery
type for charging.
Step 2
– Press the
Battery Selection Button
to pick the
charging power.
Step 3
– Press the
Start Charging Button
to start the
charging process.
LED INDICATORS
On the front panel there are also 4 LED indicators for the following
functions:
1.
Reverse Polarity
– the DC Clamps have been connected at
the wrong pole on the battery. Simply disconnect and
reconnect the DC clamps at the correct pole, restart the
charging process.
2.
Battery Fault
– the battery can be broken. If the battery fault
display does not go off after resetting the charger, the battery
may be faulty. Please consult a nearby battery service centre.
3.
Charging
– the battery is in the charging process.
4.
Full Charge
– the battery is fully charged and the battery
charger is in maintenance mode.
Содержание ADCHARGER 15
Страница 1: ......