Features
– Charges with 12 V, 10/6/2 A DC (15/9/3 A RMS)
– Self-identifying multi-stage characteristic charging curve
Soft Start
tests the battery condition. Severely discharged
batteries need the soft start step. The charging starts with a
reduced current until the voltage reaches
10V.
Bulk
is the main step, where most of the charge is returned
(60-80%). The charger delivers maximum current until the
terminal voltage has risen to the set level of 14,2V for Normal
battery selection and 14.0V for Gel battery selection.
Absorption
completes the charge up to virtually 100% at a
constant voltage. The current tapers off after the reaching the
minimum level.
Float
is the maintenance charge at the constant voltage, keeping
the batteries at the 100% charge. The Normal charging mode is
time-limited (max 10 days) while the Supply mode goes on
indefinite without damaging the battery.
SPECIAL FEATURES
Temperature Control Fan
To protect the charger from overheating, a fan is included for heat
dispensation. Also to increase the life span of the fan, a sensor
will control the on off of the fan.
Temperature Compensation
A sensor will automatically adjust the charging voltage if the
temperature is between
– 20°C to +50°C. At a high temperature
Содержание ADCHARGER 15