background image

ADJ Products, LLC - www.adj.com - Vizi Hex Wash7 Instruction Manual

Page

38

Vizi Hex Wash7

System Menu

Auto. Pro -

This function allows the internal programs to run in either stand alone or

Primary/Secondary mode. In “Primary” mode the fixture will send DMX data to other

fixtures connect via the DMX chain. In “Alone” mode the fixture will operate as a single

fixture. The program for this mode is selected in the “Select program” section of the

control menu. You can set the number of steps under “Edit program”. You can edit the

individual scenes under “Edit scenes”. With

this function, you can run the individual scenes either automatically, i.e. with the adjusted

Step-Time.

1. Access the main menu, and press the UP or DOWN buttons so that “

Function

” is

highlighted, then press ENTER.

2. Press the LEFT or RIGHT buttons until “

Auto. Pro

” is displayed, and press ENTER.

3. Either “Primary” or “Alone” will be displayed. Use the LEFT or RIGHT buttons to find

your desired setting.

4. Press ENTER to to make your selection, or press MODE button to exit.

DFSE

DFSE

- With this function you can restore the factory settings.

1. Access the main menu, and press the UP or DOWN buttons so that “

Function

” is

highlighted, then press ENTER.

2. Press the LEFT or RIGHT buttons so that

“DFSE”

is highlighted, then press

ENTER.

3. Either

“Off”

or

“On”

will be displayed, use the LEFT or RIGHT buttons to toggle

between. Selecting

“On”

will restore the factory settings.

4. Press ENTER to confirm your selection or press MODE to exit.

Содержание VIZI HEX WASH7

Страница 1: ...Rev 8 25 20 User Instructions VIZI HEX WASH7 4 0 1 0 7 6 5...

Страница 2: ...Products LLC brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby disclaim any and all liabilities for p...

Страница 3: ...omer Support 4 Safety Precautions 5 Features 6 Handling Precautions 6 Registration 6 Mounting 8 DMXSet Up 10 12 DMX Control 13 DMXTraits 14 22 ColorMacroChart 23 25 System Menu 27 Operation 44 Photome...

Страница 4: ...des 19 channels 21 channels or 27 channels The fixture has two different operating modes auto program or DMX control The Vizi Hex Wash7 can be used as a stand alone unit or in a Primary Secondary conf...

Страница 5: ...in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use...

Страница 6: ...ucts LLC will not accept any liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to this unit Vizi Hex Wash7 Handling Precautions The Vizi...

Страница 7: ...f this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Vizi Hex Wash7 General Ins...

Страница 8: ...ion material being used and periodic safety inspection of all installation material and unit If you lack these qualifications do not attempt the installation yourself These installations should be che...

Страница 9: ...will allow the fixture to run at its best and help prolong the fixture life Screw one clamp each via a M12 screw and nut onto the Omega holders Insert the quick lock fasteners of the Omega holders int...

Страница 10: ...ble path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line a...

Страница 11: ...und 1 Ground XLR Male Socket XLR Pin Configuration 3 Hot 2 Cold 2 Cold 3 Hot XLR Female Socket Pin 3 Data True positive Pin 2 Data Compliment negative Pin 1 Ground Special Note Line Termination When l...

Страница 12: ...inserting standard 5 pin data cables in to a 3 pin line a cable adapter must be used these adapters are readily available at most electric stores The chart below details a proper cable conversion Cond...

Страница 13: ...See pages 13 21 for detailed description of the DMX traits 2 To control your fixture in DMX mode follow the set up procedures on pages 9 11 as well as the set up specifications that are included with...

Страница 14: ...5 ALL GREEN LED 0 100 4 0 255 5 ALL BLUE LED 0 100 0 255 6 ALL WHITE LED 0 100 0 255 7 ALL AMBER LED 0 100 0 255 8 ALL UV LED 0 100 0 255 9 COLOR MACROS PLEASE SEE PAGE S 22 24 0 255 11 Primary DIMMER...

Страница 15: ...120 PROGRAM 6 121 140 PROGRAM 7 141 160 PROGRAM 8 161 180 PROGRAM 9 181 200 PROGRAM 10 201 220 PROGRAM 11 221 240 PROGRAM 12 241 250 PROGRAM 13 251 255 PROGRAM 14 15 PROGRAM SPEED 0 255 SLOW FAST 16...

Страница 16: ...nnel DMX Mode Basic Function AUTO PROGRAMS NORMAL ALL MOTOR RESET NO FUNCTION INTERNAL PROGRAM 1 INTERNAL PROGRAM 2 INTERNAL PROGRAM 3 INTERNAL PROGRAM 4 INTERNAL PROGRAM 5 INTERNAL PROGRAM 6 INTERNAL...

Страница 17: ...100 7 0 255 ALL BLUE LED 0 100 8 0 255 ALL WHITE LED 0 100 9 0 255 ALL AMBER LED 0 100 10 0 255 ALL UV LED 0 100 11 0 255 COLOR MACROS PLEASE SEE PAGE S 22 24 12 0 31 32 63 64 95 96 127 128 159 160 1...

Страница 18: ...ROGRAM 1 PROGRAM 2 PROGRAM 3 PROGRAM 4 PROGRAM 5 PROGRAM 6 PROGRAM 7 PROGRAM 8 PROGRAM 9 PROGRAM 10 PROGRAM 11 PROGRAM 12 PROGRAM 13 PROGRAM 14 20 17 0 225 226 235 236 255 0 255 18 0 255 PAN TILT SPEE...

Страница 19: ...ROGRAM 1 PROGRAM 2 PROGRAM 3 PROGRAM 4 PROGRAM 5 PROGRAM 6 PROGRAM 7 PROGRAM 8 PROGRAM 9 PROGRAM 10 PROGRAM 11 PROGRAM 12 PROGRAM 13 PROGRAM 14 20 17 0 225 226 235 236 255 0 255 18 0 255 PAN TILT SPEE...

Страница 20: ...andard 21 0 79 80 84 85 99 101 119 120 139 140 159 160 179 180 199 200 219 220 239 240 255 AUTO PROGRAMS NORMAL ALL MOTOR RESET NO FUNCTION INTERNAL PROGRAM 1 INTERNAL PROGRAM 2 INTERNAL PROGRAM 3 INT...

Страница 21: ...SHUTTER STROBE LED OFF LED ON STROBING SLOW FAST LED ON STROBE PULSE SLOW FAST LED ON RANDOM STROBE SLOW FAST LED ON RED CENTER LED 0 100 9 10 11 12 0 255 0 255 0 255 0 255 RED OUTER LEDS 0 100 UV CE...

Страница 22: ...9 PROGRAM 10 PROGRAM 11 PROGRAM 12 PROGRAM 13 PROGRAM 14 22 24 0 1 20 21 40 41 60 61 80 81 100 101 120 121 140 141 160 161 180 181 200 201 220 221 240 241 250 251 255 DIMMER MODE STANDARD STAGE TV ARC...

Страница 23: ...andard Channel Value Function 27 0 79 80 84 85 99 101 119 120 139 140 159 160 179 180 199 200 219 220 239 240 255 AUTO PROGRAMS NORMAL ALL MOTOR RESET NO FUNCTION INTERNAL PROGRAM 1 INTERNAL PROGRAM 2...

Страница 24: ...UV 0 DMX VALUES 41 44 Red 255 Green 97 Blue 77 White 74 Amber 0 UV 0 DMX VALUES 45 48 Red 255 Green 71 Blue 77 White 71 Amber 0 UV 0 DMX VALUES 25 28 DMX VALUES 49 52 Red 255 Green 83 Blue 134 White...

Страница 25: ...ber 0 Amber 0 UV 0 UV 0 DMX VALUES 117 120 Red 151 Green 138 Blue 255 White 138 Amber 0 UV 0 DMX VALUES 121 124 Red 138 Green 169 Blue 255 White 138 Amber 0 UV 0 DMX VALUES 125 128 Red 255 Green 255 B...

Страница 26: ...UES 225 228 Red 209 Green 219 Blue 182 White 0 Amber 0 UV 0 DMX VALUES 229 232 Red 42 Green 165 Blue 85 White 0 Amber 0 UV 0 DMX VALUES 233 236 Red 255 Green 0 Blue 0 White 0 Amber 0 UV 0 DMX VALUES 2...

Страница 27: ...t Chan Value SecdSet Auto Pro PAN Secd 1 Secd 2 Secd 3 Primary Alone DFSE ON OFF Time Info Current TotalTime LastClear TimerPIN ClearLast Checkthecurrentrunning time H Totaltime Hours Clear the runnin...

Страница 28: ...ess the UP or DOWN buttons so that Receive is highlighted then press ENTER 2 Set Address will now be displayed press ENTER The current DMX address will now be displayed 3 Use the UP or DOWN buttons to...

Страница 29: ...UP and DOWN buttons to toggle between 5 Press ENTER to confirm your selection or press MODE to exit To use this function follow these instructions To adjust the address of your unit you must first go...

Страница 30: ...he main menu Press the UP or DOWN buttons so that Function is highlighted then press ENTER 2 Press the LEFT or RIGHT buttons until Status is displayed press ENTER 3 Press LEFT or RIGHT buttons until N...

Страница 31: ...MODE button to access the main menu Press the UP or DOWN buttons so that Function is highlighted then press ENTER 2 Press the LEFT or RIGHT buttons until Status is displayed press ENTER 3 Press LEFT...

Страница 32: ...ons to toggle between 5 Press ENTER to confirm your selection or press MODE to exit Stand By With this function the LEDs and step motors will power off if there is no DMX signal within 15 mins factory...

Страница 33: ...ss MODE to exit RDM PID RDM stands for Remote Device Management This feature lets you control every aspect of your fixture remotely from an RDM controller Manual settings like adjusting the DMX addres...

Страница 34: ...utton to access the main menu Press the UP or DOWN buttons so that Function is highlighted then press ENTER 2 Press the LEFT or RIGHT buttons until LCD Set is displayed press ENTER 3 Press LEFT or RIG...

Страница 35: ...Either Off or On will be displayed use the LEFT or RIGHT buttons to toggle between 5 Press ENTER to confirm your selection or press MODE to exit DispFlash With this function active the display will f...

Страница 36: ...this function you can change the temperature display to show either Celsius or Fahrenheit 1 Press the MODE button to access the main menu Press the UP or DOWN buttons so that Function is highlighted...

Страница 37: ...e DMX value of each DMX channel that is currently being used at the time 1 Access the main menu and press the UP or DOWN buttons so that Function is highlighted then press ENTER 2 Press the LEFT or RI...

Страница 38: ...ith the adjusted Step Time 1 Access the main menu and press the UP or DOWN buttons so that Function is highlighted then press ENTER 2 Press the LEFT or RIGHT buttons until Auto Pro is displayed and pr...

Страница 39: ...total running time 1 Press the MODE button to access the main menu Press the UP or DOWN buttons so that Information is highlighted then press ENTER 2 Press the LEFT or RIGHT buttons until Time Info is...

Страница 40: ...is displayed and press ENTER 4 The Timer Pin is 050 5 Press ENTER to confirm or press MODE to exit Clear Last This will allow you to clear the LED running time You need to put in the Timer Pin before...

Страница 41: ...allow you to see any errors that have occured 1 Press the MODE button to access the main menu Press the UP or DOWN buttons so that Information is highlighted then press ENTER 2 Press the LEFT or RIGHT...

Страница 42: ...Reset M is displayed 3 Press ENTER to reset or press MODE to exit Test Chan With this function you can test each channel function 1 Press the MODE button to access the main menu Press the UP or DOWN...

Страница 43: ...ms to be installed and recalled directly from the fixture s control board Programs can be created and stored using the fixture s control board or by using an external DMX controller Select Pro This fu...

Страница 44: ...Any unit can act as a Primary or as a Secondary 1 Using standard XLR cables daisy chain your units together via the XLR connector on the rear of the units Remember the Male XLR connector is the input...

Страница 45: ...WiFly and set the Wireless address The address must match the address set on the WiFly Transceiver 2 After you have set the WiFly address follow the DMX instructions on page 26 to select your desired...

Страница 46: ...3 5 8 10 1 1 2 2 3 4 Beam opening m 3 4 7 0 23 0 11 0 31 0 41 0 51 7 Diameter m 10 0 37 0 17 0 53 0 73 0 90 10 Diameter m 4486 15570 1488 15140 4298 103 36850 1745 5884 607 5735 1606 54 14930 774 2720...

Страница 47: ...1503 405 12 3619 103 366 31 361 91 5 884 46 166 13 163 40 1 402 27 95 6 94 22 0 235 15 61 3 61 12 0 157 Red LEDs Green LEDs Blue LEDs White LEDs Amber LEDs UV LEDs Full LEDs Beam angle 58 Field angle...

Страница 48: ...e quantity that can be connected is 5 fixtures maximum 110V and a maximum 11 fixture s 240V After maximum limit has been reached you will need to use a new power outlet They must be the same fixtures...

Страница 49: ...ng 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics and mirror with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner an...

Страница 50: ...or refurbished parts and will absorb all expensesfor warranty service and repair labor by reasonof defects in material or workmanship The sole responsibility of ADJ Products LLC underthis warranty sha...

Страница 51: ...ADJ Products LLC www adj com Vizi Hex Wash7 Instruction Manual Page 51 Vizi Hex Wash7 Notes...

Страница 52: ...L x 8 W x 15 75 H 300 x 200 x 400mm Weight 19 Lbs 8 5 kgs Colors RGBWA UV Fuse 5A 120V 3A 240V Duty Cycle None DMX 3 DMX Channel Modes 19 Channels 21 Channels or 27 Channels Working Position Any Safe...

Страница 53: ...Angeles CA 90040 USA Tel 323 582 2650 Fax 323 725 6100 Web www adj com E mail info americandj com A D J Supply Europe B V Junostraat 2 6468 EW Kerkrade The Netherlands service adjgroup eu www adj eu...

Отзывы: