The intermediate 2 multi slope levels and 2 multi slope times are expressed as a percentage from the
normal saturation level and integration time.
The node points are configurable by sequentially selecting them with the MultiSlopeNodeSelector.
MultiSlopeLevel and MultiSlopeTime are read and written for the selected node.
PARAMETER NAME
INTERFACE
ACCESS
VISIBILITY
RANGE
DEFAULT
MultiSlopeNumberOfSlopes
IInteger
R/W
E
1 to 3
1
MultiSlopeNodeSelector
IInteger
R/W
E
1 - 2
1
MultiSlopeLevel[MultiSlopeN
odeSelector]
IInteger
R/W
E
1 to 100
50 (node 1)
70 (node 2)
MultiSlopeTime[MultiSlopeNo
deSelector]
IInteger
R/W
E
1 to 100
80 (node 1)
95 (node 2)