![Adimec CoaXPress Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/adimec/coaxpress/coaxpress_operating-and-users-manual_2851434011.webp)
OPERATING AND USER MANUAL QUARTZ series CXP
11
Installation hardware
3.
In this chapter the electrical interfaces as well as the mechanical and optical interface are described.
If a lens, cabling and frame grabber is available and installed, one may refer directly to the quick start
section at the end of this chapter. The other sections describe the interfaces in detail.
Electrical interface - CoaXPress
3.1
The camera has two BNC connectors for the CoaXPress interface which serve the purposes listed in
the table below.
Refer to section 6.1.2 for details on the CXP datarate configurations.
CABLE 1
CABLE 2 (optional)
Power
Power (additional)
Video
Video (additional)
Control
-
Triggering
-
Power
3.1.1.
Power is supplied over the CXP link.
Each cable could transfer up to 13W, according to the CoaXPress standard.
The power actually drawn by the camera is listed below. A single cable is sufficient to power the cam-
era.
Q-2A340
Qr-2A340
Q-4A180
Qr-4A180
<10 W
Power consumption @ 24 Volt.
Table 3.1:
Video, control and trigger
3.1.2.
The CoaXPress interface is designed to transfer video from camera to frame grabber as well as control
data, triggering and power from the grabber to the camera.
The maximum cable length is 40 meter at CXP-5.
For a complete description of the CoaXPress interface please refer to the CoaXPress specification.
Electrical interface - strobe and trigger
3.2
An input for external triggering of the camera is available at the I/O connector.
Also a trigger output signal from the camera to control an external flash light is available at this
connector. The input and output are fully programmable. For reference see paragraph 6.5.
The input and output are galvanically isolated from the internal camera electronics by means of an
optocoupler.