OPERATING AND USER MANUAL QUARTZ series CXP
36
Defect pixel correction (ICategory: DefectPixel)
6.10
In Quartz series cameras defect pixels are corrected in real time.
Adimec does not release cameras with more than 1 adjacent defect pixel upon delivery. However,
additional defect pixels can be user-programmed.
Up to 2 adjacent pixels can be corrected. More than 2 adjacent defect pixels can be user
programmed, but will not result in a reliable correction.
Correction is done by interpolation of the adjacent pixels according to the method illustrated in figures
6.4 and 6.5.
The defect pixel list has a capacity of 500 pixels.
Defect pixel correction method on monochrome cameras.
Figure 6.4:
Defect pixel correction method on color cameras.
Figure 6.5:
Find below the list of all commands related to the defect pixel correction. In the next subsections they
are explained in more detail.
PARAMETER NAME
INTERFACE
ACCESS
VISIBILITY
RANGE
DEFAULT
DefectPixelTotal
IInteger
R
E
DefectPixelSelect
IInteger
R/W
E
1 to DefectPixelTotal
1
DefectPixelReadX
IInteger
R
E
1 to SensorWidth
DefectPixelReadY
IInteger
R
E
1 to SensorHeight
DefectPixelWriteX
IInteger
R/W
E
1 to SensorWidth
DefectPixelWriteY
IInteger
R/W
E
1 to SensorHeight
DefectPixelAdd
IICommand
W
E
DefectPixelRemove
IICommand
W
E
DefectPixelClearAll
IICommand
W
E
DefectPixelCorrectionEnable
IBoolean
R/W
E
False / No
True / Yes
True / Yes
DefectPixelTestMode
IEnumera-
tion
R/W
E
TestModeDisabled
MarkDefectsWhit-
eOnVideo
MarkDefectsBlack-
OnVideo
ShowDefectAsWhi-
teOnBlackBack-
ground"
TestModeDis-
abled
DefectPixelFactoryRestore
IICommand
W
E
D
0
½
½
D
0
1
0
D
0
1
D
0
D
D
0
½
½
0
0
x
x
D
0
1
0
0
x
x
D
0
D
0
1
0
0
x
x
D
0