![Adeunis RF MOTION V2 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/adeunis-rf/motion-v2/motion-v2_technical-reference-manual_2850724007.webp)
Date: 02/12/2019
Page 7 / 15
adeunis
®
Manage & optimize your assets & services
283, rue louis Néel 38920 CROLLES, France
Tél : +33 (0)4 76 92 07 77 E-mail : [email protected]
www.adeunis.com
222
LORAWAN
NWK_SKEY (first part
– MSB)
Hexadecimal
Default: 0
Parameter encoded on 16 bytes. Each of the 4 registers
contains 4 bytes.
223
LORAWAN
NWK_SKEY (second
part - MID MSB)
Hexadecimal
224
LORAWAN
NWK_SKEY (third part
- MID LSB)
Hexadecimal
225
LORAWAN
NWK_SKEY (fourth
part – LSB)
Hexadecimal
226
LORAWAN APP_SKEY
(first part – MSB)
Hexadecimal
Default: 0
Parameter encoded on 16 bytes. Each of the 4 registers
contains 4 bytes.
227
LORAWAN APP_SKEY
(second part - MID
MSB)
Hexadecimal
228
LORAWAN APP_SKEY
(third part - MID LSB)
Hexadecimal
229
LORAWAN APP_SKEY
(fourth part – LSB)
Hexadecimal
257
Configuration RX2
Decimal
Default: 1
0: Channel disabled
1: Default configuration: LoRaWAN Other: User configuration
260
Reserved
Decimal
Do not use
261
Reserved
Decimal
Do not use
280
NETWORK ID
Hexadecimal Default: 0 Read only
281
DEVICE ADDRESS
Hexadecimal Default: 0
NOTE 1: The “Over The Air Activation” (OTAA) mode uses a JOIN phase before being able to transmit on the
network. This mode uses the APP_ EUI (S214 and S215) and APP_KEY (S216 to S219) codes during this phase to
create the keys for network communication. Once this phase is completed, the codes APP_sKEY, NWK_sKEY and
DEVICE ADDRESS will be present in the corresponding registers. A new JOIN phase is started every time the device
exits Command mode, a reset is performed, or the device is turned on.
Codes:
• APP_EUI identifier for global use (provided by default by adeunis®)
• APP_KEY device application key (provided by default by adeunis®)
The “Activation by personalization” (ABP) mode has no JOIN phase; it transmits directly on the network using the
codes NWK_sKEY (S222 to S225), APP_sKEY (S226 to S229) and DEVICE ADDRESS (S281) to communicate.
Codes:
• NWK_sKEY network session key (provided by default by adeunis®)
• APP_KEY applicative session key (provided by default by adeunis®)
• DEVICE ADDRESS Address of the device in the network (provided by default by adeunis®)
Register Size
(bytes) Base Description
Default
Value
Range
(Min-
Max)
Minimum
required
Application
version
Comments
303
1
10
LORAWAN
Confirmed
mode
0
0-1
V1.2.0
LoRaWAN only – activation or
deactivation of the confirmed
mode
0: deactivation