Decoding example:
Offset
(in byte) Data
Description
0
0x33
Frame code
1
0x80
Frame counter: 4
Bit1@0: LowBat not detected
2
0x04
invalid register
3-4
0x0020 32: register S032 does not exist (should be S3XX)
2.2.11 Transmit conditions
Frame
code
Description
Sending conditions
0x10
Status (configuration)
•
Product start up
•
Exit configuration mode (AT command)
•
Reception of frame 0x01 (get product
config)
0x1F
Digital input
configuration
•
Product start up if at least one input is
activated
0x20
Network configuration
•
Product start up
•
Exit configuration mode (AT command)
•
Reception of frame 0x02 (get network
config)
0x30
Keep alive
•
Periodically if no periodical data is defined
0x5C
Periodic data
•
Periodically
0x5D
Presence alarm
•
Beginning or end of presence
0x50
Luminosity alarm
•
Threshold crossing
0x51
0x52
Digital input alarm
•
Threshold crossing
2.3 Downlink Frame format
2.3.1 Get applicative configuration (0x01)
Offset
(in byte) Data
Description
0
0x01
Frame code
When the device receives the downlink, it will generate a product configuration frame (0x10).
2.3.2 Get network configuration (0x02)
Offset
(in byte) Data
Description
0
0x02
Frame code
When the device receives the downlink, it will generate a network configuration frame (0x20).
2.3.1 Get registers (0x40)
This frame (0x40) allows you to inform the device through the network that it must send the values of specific S3XX
registers in an uplink frame (0x31).