344
1
10
Low threshold
hysteresis
0
0 … 100
%
380
1
16
Configuration
digital input 1
(button)
0x41
<7:4> Debounce
duration
0: no debounce
1: 10 ms
2: 20 ms
3: 50 ms
4: 100 ms
5: 200 ms
6: 500 ms
7: 1 s
8: 2 s
9: 5 s
A: 10 s
B: 20 s
C: 40 s
D: 60 s
E: 5 minutes
F: 10 minutes
<3:0> Type
0 = Deactivated
1 = Event ON
2 = Event OFF
3 = Event ON/OFF
381
2
10
Digital input 1
threshold
1
1 – 65535
Number of detections
When the number of
detected events becomes
above this threshold, an
alarm is triggered
382
1
16
Configuration
digital input 2
0x0
(deactivated)
<7:4> Debounce
duration
0: no debounce
1: 10 ms
2: 20 ms
3: 50 ms
4: 100 ms
5: 200 ms
6: 500 ms
7: 1 s
8: 2 s
9: 5 s
A: 10 s
B: 20 s
C: 40 s
D: 60 s
E: 5 minutes
F: 10 minutes
<3:0> Type
0 = Deactivated
1 = Event ON
2 = Event OFF
3 = Event ON/OFF
383
2
10
Digital input 2
threshold
1
1 – 65535
Number of detections
When the number of
detected events becomes
above this threshold, an
alarm is triggered