![Adeunis RF MOTION V2 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/adeunis-rf/motion-v2/motion-v2_technical-reference-manual_2850724010.webp)
Date: 02/12/2019
Page 10 / 15
adeunis
®
Manage & optimize your assets & services
283, rue louis Néel 38920 CROLLES, France
Tél : +33 (0)4 76 92 07 77 E-mail : [email protected]
www.adeunis.com
2.2.3 Network configuration (0x20)
This frame is sent following the reception of a frame with code 0x02, or at the start of the product.
2.2.3.1 LoRaWAN 868
Offset (in byte) Data
Description
0
0x20
Frame code
1
Status
Status byte
2
S220
LoRaWAN options
Bit 0: Activation of the ADR ON (1)/ OFF (0)
Bit 1: Reserved
Bit 2: DUTYCYCLE ON (1)/ DUTYCYCLE OFF (0)
Bits 3 & 4: Reserved
Bits 5 to 7: Reserved
3
S221
Provisionning mode (0: ABP, 1: OTAA)
Decoding example:
Offset (in byte) Data
Description
0
0x20
Frame code
1
0x20
Frame counter: 1
Bit1@0: no LowBat
2
0x05
Duty cycle activated
ADR ON
3
0x01
OTAA
2.2.3.1 Sigfox 868
Offset
(in byte)
Data
Description
0
0x20
Frame code
1
Status
Status byte
2
S202
Retry count
Decoding example:
Offset
(in byte)
Data
Description
0
0x20
Frame code
1
0x20
Frame counter: 1
Bit1@0: no LowBat
2
0x02
2 retries
2.2.4 Keep alive frame (0x30)
This frame is sent after an amount of time determined by S300 register if no periodic data is configured
Offset
(in byte) Data
Description
0
0x30
Frame code
2.2.5 Periodic data frame (0x5C)
The acquisition period is defined by: S321 * S320
The sending frequency is defined by: S321 * S320 * S301
The number of samples per channel is defined by: S301