Chapter 7 - IP-65 Option
104
Adept Cobra s800 Inverted Robot User’s Guide, Rev C
Pressurizing the Robot
The user must supply compressed air to maintain positive air pressure inside the robot.
1. Remove the shipping plug from the compressed air fitting located just above the
AIB. See
.
Figure 7-8. Compressed Air Fitting on Robot
2. Connect a compressed air source to the air fitting. The specification for the
regulated air supply is shown in
.
Table 7-1. Compressed Air Specifications
Required Air Pressure
Required Air Flow, Minimum
3 bar, ± 10%
(44 PSI, ± 10%)
57 liters per minute
(2 cubic feet per minute)
CAUTION:
The compressed air supply must be
clean
and
dry
and it must be on continuously to maintain a positive
air pressure inside the robot. Failure to do this could result
in moisture or particle buildup inside the robot and lead to
reduced performance or damage to the robot. This will
also void your warranty.