Chapter 7 - Optional Equipment Installation
86
Adept Cobra s600/s800 Robot User’s Guide, Rev H
Figure 7-6. OP3/4 and SOLND Circuits
EOAPWR Connector
This 4-pin connector (see
) provides 24 VDC power and ground for
user applications. See
for the pinouts and
for the output
specifications.
Table 7-3. EOAPWR Connector Pinout
Pin #
Description
Pin Location
1
24 VDC (see
for
current specs)
EOAPWR Connector
as viewed on robot
2
Ground
3
24 VDC (see
for
current specs)
4
Ground
Mating Connector:
AMP/Tyco #172167-1, 4-pin Mini-Universal Mate-N-Lok
AMP/Tyco #770985-1, Pin Contact, Mini-Univ. Mate-N-Lok
Pin 1
Pin 2
Pin 3
Pin 4
For optional second set of solenoids, or
other user supplied devices.
Pin 1
Pin 2
Pin 3
Pin 4
For optional Robot Solenoid Kit installation, or
other user supplied devices.
+24VDC
OP3/4 Connector Circuit
Signal 3003
GND
Signal 3004
GND
Load
Load
(equivalent
circuit)
+24VDC
SOLND Connector Circuit
Signal 3001
GND
Signal 3002
GND
Load
Load
(equivalent
circuit)
1
2
4
3