3-7
Table of Device Addresses
This Device
Uses Address
Reports as
††
Enabled By…
RF Receiver
00
100
*56 zone programming: input device type entry
Alternative Communication
Media (ACM)
†
03
103
automatic if output to ACM field *29 enabled
Telecommand Voice Module
17-23
117-123
same as keypad enables; see below
Zone Expanders** (4219/4229):
module 1 (zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 (zones 33 - 40)
module 5 (zones 41 - 48)
07
08
09
10
11
107
108
109
110
111
*56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
Relay Modules (4204/6164):
module 1/6164 relay only
module 2/6164 relay only
module 3/6164 relay only
module 4/6164 relay only
12
13
14
15
112
113
114
115
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
116
117
118
119
120
121
122
123
data field programming as listed below:
always enabled for partition 1, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
5800TM Module
28
n/a
automatic
† ACM devices include: 7845i Ethernet Interface Internet/Intranet, AI4164RS/AI4164ETH RS485/Ethernet Eureka Network
Interface
†† Addressable devices are identified by “1” plus the device address when reporting. Enter a report code for zone 91 to enable
addressable device reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit
identification keypad display options.
** or 6164 Keypad using zones; address 07 = zones 9-12, 08 = zones 17-20, 09 = zones 25-28, 10 = zones 33-36, 11 = zones 41-44
Содержание VISTA-48D
Страница 1: ...VISTA 48D Security System Installation and Set Up Guide K0749 4EN 1 03...
Страница 2: ...ii...
Страница 28: ...Installation Instructions 3 8...
Страница 60: ...Installation Instructions 5 20...
Страница 75: ...8 5 NOTES...
Страница 76: ...Installation Instructions 8 6 NOTES...
Страница 79: ...9 3 Figure 17 Summary of Connections...