3-3
4. If using child-not-home pager report, define the report schedule using Scheduling mode (master
code + [#] [6] [4] then select event type “03”).
5. If using a function key to manually send a message to a pager, see Function Keys paragraph below.
6. If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones
associated with each pager (zone lists 9-12).
Function Keys
To assign functions to the function keys, use *57 Function Key menu mode.
To assign emergency key functions (function key option “00”), first program the respective emergency
zone number (95 for “A” key, 96 for “C” key, 99 for “B” key) with the desired zone type u sing *56 Zone
Programming mode, then use *57 Function Key menu mode to assign the desired key.
If using a function key to activate a relay action (*57 Menu mode key function 07), use *79 Menu
mode to map the output, and use *80 Menu mode to define the output’s action; select system
operation type “66.”
If using a function key for a user macro, use *57 menu mode to activate the desired key, then define
the actual macro functions using the user code + [#] + [6] [6] command.
Output Devices
To program a device for manual activation (user code + [#] [7] / [#] [8] + 2-digit device number) or for
scheduled automatic activation, simply map the device using *79 Menu mode.
To program a device to automatically activate upon a system event (or function key), use *79 Menu
mode to map the device, then use *80 Menu mode to define the automated device action.
If the device action is based on more than one zone, use *81 Zone List menu mode to assign the zones.
Zone Type Definitions
You must assign a zone type to each zone, which defines the way in which the system responds to
faults in that zone. Zone types are defined below.
Zone Type
Description
Type 00: Zone Not Used
Program a zone with this zone type if the zone is not used.
Type 01
Entry/Exit Burglary #1
Assign to zones that are used for primary entry and exit.
Provides entry delay when zone type is faulted if control is armed in the Away,
Stay, or Night-Stay modes.
No entry delay provided when the panel is armed in the Instant/Maximum mode.
Entry delay #1 is programmable for each partition.
Exit delay begins whenever the control is armed, regardless of the arming mode
selected, and is programmable for each partition. (If Final Contact Set exit option
is selected in field *88, exit delay remains on indefinitely until the last zone in
zone list 8 is restored; once the last zone is restored, exit delay is then 5 seconds.)
Type 02
Entry/Exit Burglary #2
Assign to zones that are used for entry and exit and require more time than the
primary entry/exit point.
Provides a secondary entry delay, in same manner as entry delay #1.
Entry delay #2 is programmable for each partition.
Exit delay is the same as described for Type 01.
Type 03
Perimeter Burglary
Assign to all sensors or contacts on windows and infrequently used exterior doors .
Provides an instant alarm if the zone is faulted when the panel is armed in the
Away, Stay, Night-Stay, Instant or Maximum modes.
Type 04
Interior Follower
Assign to a zone covering an area such as a foyer, lobby, or hallway through
which one must pass upon entry (to and from the keypad).
Provides a delayed alarm (using the programmed entry 1 time) if the entry/exit
zone is faulted first. Otherwise this zone type gives an instant alarm.
Active when the panel is armed in the Away mode.
Bypassed automatically when the panel is armed in the Stay or Instant modes;
if armed in Night-Stay mode, zones assigned to zone list 05 (night-stay zone list)
are not bypassed when system armed in Night-Stay mode.
Содержание VISTA-48D
Страница 1: ...VISTA 48D Security System Installation and Set Up Guide K0749 4EN 1 03...
Страница 2: ...ii...
Страница 28: ...Installation Instructions 3 8...
Страница 60: ...Installation Instructions 5 20...
Страница 75: ...8 5 NOTES...
Страница 76: ...Installation Instructions 8 6 NOTES...
Страница 79: ...9 3 Figure 17 Summary of Connections...