![ADE STAN07 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/ade/stan07/stan07_operating-manual_2849736014.webp)
13
STAN07-210324-Rev005-UM-en
The following diagram shows the procedure:
Recalling average piece weights
To recall an APW, hold the
key for more than one second in counting mode.
Then press ► first, then select the stored CLU using the navigation keys ▲ and ▼ or ► and ◄ and
confirm it with the
key.
The following diagram shows the procedure:
Performing check weighing in weighing mode
Target or tolerance values previously stored in the PLU used are required to perform check weighing.
In weighing mode, press the
key for more than one second until the indicator shows the following
in the display:
.
The letter to the right of the display indicates whether the check weighing function is enabled or disabled:
"Y" = enabled; "n" = disabled.
To enable the check weighing function, press the ▲ key to select "Y" and confirm with the
key.
The number of the PLU appears in the display, for example [PLU: 00].
Select the desired PLU using the navigation keys ▲ and ▼ or ► and ◄ and confirm your selection with
the
key.
Target value, HI and LO are automatically displayed before the start of check weighing.
Now place the item to be weighed on the weighing platform. The bar graph in the display now shows
whether the weight placed is below, within or above the tolerance range.
below
within the tolerance range
above
To disable check weighing, hold the
key for more than one second and change your selection of
the check weighing function from "Y" to "n" by pressing the ▼ key. Confirm with
.
The bar graph disappears from the display.
Check weighing can also be supported visually by a colour change of the display. Using three different,
changing background colours, the degree of achievement of the target weight can be viewed. The
settings are made in the parameter settings.