WARNINGS

A warning statement in this manual identifies a condition or practice which, if not cor-
rected or discontinued immediately could lead to patient injury, illness, or death.

NOTE:

Systolic Assist and pulse measurement functions are NOT motion tolerant.

(Pressure readings ARE). In a dynamic environment, systolic assist and pulse rate dis-
play may not operate correctly.

Caution:

Federal law restricts this device to sale by or on the order of a physician or

licensed healthcare practitioner.

Caution:

Leaking batteries can damage the unit.

Caution:

Remove the batteries when the unit will not be used for an extended period

of time.

Caution:

Your digital aneroid is a medical device designed for use by trained med-

ical professionals. Keep out of the reach of children.

Caution:

Your digital aneroid is not field serviceable.

Caution:

You should not use any tool to open the device nor should you attempt to

adjust anything inside the device.

Caution:

To stop the operation of your digital aneroid at any time, open the air re-

lease valve as you would on any mechanical blood pressure instrument, and the air
in the cuff will be rapidly exhausted.

Caution:

Your digital aneroid is designed for normal blood pressure measurement

at the upper arm or thigh on healthy skin. Proper use of this device is essential for
accurate measurement.

Caution:

Do not inflate your digital aneroid unit to more than 300 mmHg.

Warning:  

When using with an infant or child cuff, extra care must be taken to pre-

vent over-inflation. With smaller cuffs (infant or child) the cuff can inflate to over
300mmHg with just two full compressions of the bulb.  To prevent discomfort or in-
jury to the patient and damage to the instrument, bulb should only be partially
squeezed, so that each “stroke”  inflates the cuff in 40mmHg to 60mmHg increments
until inflated to the desired level.

Warning:

If luer lock connectors are used in the construction of tubing, there is a possibility

that they might be inadvertently connected to intravascular fluid systems, allowing air
to be pumped into a blood vessel. Immediately consult a physician if this occurs.

Warning:

Do not allow a blood pressure cuff to remain on patient for more than 10

minutes when inflated above 10 mmHg. This may cause patient distress, disturb
blood circulation, and contribute to the injury of peripheral nerves.

Warning:

Safety and effectiveness with neonate cuff sizes 1 through 5 is not established.

Warning: 

This product may contain a chemical known to the state of California to cause

cancer, birth defects, or other reproductive harm.

Содержание Diagnostix E-sphyg 7002

Страница 1: ...1 e sphygTM User s Manual DigitalAneroid...

Страница 2: ...ormance You ll quickly appreciate the results for you now own one of the finest sphygmomanometers that money can buy With proper care and maintenance your ADC blood pressure instrument is sure to prov...

Страница 3: ...d Maintenance 12 Disinfection and Sterilization 12 Specifications 13 Standards 13 Limited Warranty 14 Product Registration 15 This manual is intended to assist the user in the safe and efficient opera...

Страница 4: ...digital e sphygTM aneroid also has several features not available in a more traditional mechanical gauge The systolic assist function will give you a visual alert when you are ap proaching the patient...

Страница 5: ...igned for normal blood pressure measurement at the upper arm or thigh on healthy skin Proper use of this device is essential for accurate measurement Caution Do not inflate your digital aneroid unit t...

Страница 6: ...ometer consists of a digital manometer gauge complete inflation system ADCUFFTM calibrated nylon cuff latex free inflation bladder squeeze bulb and the ADFLOWTM valve a zippered carrying case and oper...

Страница 7: ...acing in the correct direction 4 Replace the battery cover and tighten the screw 5 Rotate the clip back Note You should replace the batteries if The weak battery mark appears in the display Nothing ap...

Страница 8: ...our hand during use ADCUFFTM nylon cuffs are specially designed to promote the accurate determination of blood pressure Index and range markings ensure use of the correct cuff size The artery mark ind...

Страница 9: ...display this information on the LCD screen once the cuff has been deflated Note Systolic assist and pulse display features are NOT motion tolerant Exces sive movement may interfere with accurate displ...

Страница 10: ...per second and stop to check at the following test points 299mmHg 250 mmHg 150 mmHg 100 mmHg and 50 mmHg Your gauge should be within 3 mmHg of your reference stan dard ADC recommends using the most se...

Страница 11: ...to switch the unit off or the unit will automatically switch off after 60 seconds E3 Data Error Remove and reinsert the batteries If this error keeps occurring return the device to your local distribu...

Страница 12: ...a damp cloth To help preserve it from cracking or discoloring wipe with a soft cloth moistened with ethanol Valves Clean the surface with a dry fabric such as soft cotton material Remove dust from fil...

Страница 13: ...ure 32 115 F 0 46 C Humidity 85 Relative Humidity max STORAGE ENVIRONMENT Temperature 4 131 F 20 55 C Humidity 90 Relative Humidity max non condensing Dimensions 3 L X 23 8 W X 11 8 H Weight 3 14 oz G...

Страница 14: ...by abuse mis use accident or negligence Incidental special or consequential damages Some states do not allow the exclusion or limitation of incidental special or consequential damages so this limitati...

Страница 15: ...00 232 2670 fax 631 273 9659 www adctoday com email info adctoday com 2015 ADC All rights reserved No one is permitted to reproduce or duplicate in any form this manual or any part thereof without the...

Отзывы: