Is Elemental Mercury dangerous? 

Yes, it can be. Once vaporized, the lungs readily absorb elemental mer-
cury from inhaled air. High level acute doses and lower level chronic
doses are both causes for concern.
If accidentally ingested, very small amounts of elemental mercury will
not be absorbed by the digestive system and will be excreted.
Some forms of mercury COMPOUNDS (not the type used in blood
pressure instruments) are highly toxic and particularly dangerous.
These should NOT be confused with elemental mercury.
Because there is so little actual mercury in a mercurial blood pressure
instrument, the exposure to a spill or leakage, if properly and
promptly contained, will generally pose little if any health risk.
DIAGNOSTIX

Blood Pressure instruments use less than 2 ounces of

99.9999% pure elemental mercury. 

What should I do in the event of a spill?

First, isolate the area to prevent further contamination or spread of the
spilled liquid. Spilled mercury should be picked up at once since the
mercury will vaporize rapidly and may contaminate the surrounding
air. 
Larger spills involving the entire contents of the mercury instrument
(about 2 oz.) may be cleaned up with a commercially made mercury
suction pump. Do not dry sweep or use ordinary vacuum cleaners on
floors exposed to mercury spills since this may produce additional
hazardous vapors. 
In the unlikely event of a spill, it will most likely involve very small
amounts of just a few drops of spilled mercury. These smaller amounts
may be picked up with mercury absorbent sponges or gently swept
into a collection container using a soft bristled DISPOSABLE brush.
(Remember to dispose of the brush after use). 
Carpet, crevices, and other difficult to clean areas may be cleaned using
a mercury absorbent powder that reacts with mercury to form a harm-
less amalgam. 
The suction pump, sponges, and powder are available through labora-
tory and safety supply companies.

As a convenience to our customers, a mercury spill kit may be
obtained directly from ADC by calling our customer service de-
partment toll-free at 1-800-ADC-2670 (p/n 980SK).

Содержание Diagnostix 720

Страница 1: ...JUSTINCASE ADC GUIDELINES for the Proper Maintenance Handling Cleanup and Transportation of Mercurial Blood Pressure Devices...

Страница 2: ...future reference PREVENTIVE MAINTENANCE Because the mercury units do not rely on moving parts such as metal bellows diaphragms gears or other sources of mechanical wear only an occasional inspection o...

Страница 3: ...n tipped in the direction of the reservoir and returned to a vertical position before the new mercury level is observed Re peat the process as necessary to bring the mercury up to the 0 cali bration m...

Страница 4: ...e mer cury has been lost add enough through the top of the plastic tube to bring the rim of the mercury meniscus to the 0 calibration mark Then replace the knurled cap at the top of the graduated plas...

Страница 5: ...ed plastic cartridge tube Designed from space age polymers the tube exhibits remarkable performance stability It will not crack craze or shatter Yellowing a problem that plagued first generation plast...

Страница 6: ...lled mercury should be picked up at once since the mercury will vaporize rapidly and may contaminate the surrounding air Larger spills involving the entire contents of the mercury instrument about 2 o...

Страница 7: ...do not have one they can be ordered from most laboratory safety supply houses As a conven ience to our customers a basic spill kit can be purchased directly from ADC Call our customer service departme...

Страница 8: ...What do I do with the collected mercury and broken instrument You have two options You can dispose of the collected mercury and damaged instrument in accordance with your state and local environ menta...

Страница 9: ...n below Note We can only accept the return of ADC s DIAGNOSTIX mer curial instruments for repair services PACKING AND SHIPPING INSTRUCTIONS Important Note Failure to follow the proper packing and ship...

Страница 10: ...osed with a strip of adhesive tape Carefully place the specially authorized return address label to the top of the box 9 Ship via UPS Prepaid Ground Service ONLY No other carriers are authorized use f...

Страница 11: ...ange top cap filter Clean or replace mercury Add mercury Clean tube in accordance with en closed instructions Change top cap filter Make sure cartridge tube is securely seated Replace silicone gaskets...

Страница 12: ...follow the links Consult this manual for basic service and maintenance procedures mentioned in this troubleshooting guide If any of the problems persist contact ADC s Customer Service Department Toll...

Отзывы: