background image

28

NOTE:

Blood pressure is subject to fluctuations even in healthy people.

Please remember that 

comparable blood pressure measurements

always require the same time and the same conditions!

These are

normally quiet conditions. If you follow the procedure described earlier and
still get fluctuations of blood pressure of greater than 15 mmHg and/or you
repeatedly hear irregular pulse tones, consult your doctor.

Attention!

Should any technical malfunctions arise in the blood pressure monitor,
please contact the dealer where you bought the device or ADC

®

Never

attempt to repair the instrument yourself!

Any unauthorized opening of

the instrument invalidates all warranty claims.

11. CARE AND MAINTENANCE

Do not expose the device to either extreme temperatures, humidity,
dust or direct sunlight.

Handle the cuff carefully and avoid all types of stress through twisting
or buckling in order not to damage the sensitive air-tight bubble.

Clean the device with a soft, dry cloth. Do not use gas, thinners or
similar solvents. Spots on the cuff can be removed carefully with a
damp cloth and soapsuds. Do not submerge the cuff in water!

Handle the tubing carefully.
Keep the tube away from sharp edges.

Do not drop the monitor or treat it roughly in any way.

Never open the monitor!
This invalidates the manufacturer’s warranty.

Содержание Advantage 6021N

Страница 1: ...HIS MEDICAL INSTRUMENT MUST BE USED ACCORDING TO INSTRUCTIONS TO ENSURE ACCURATE READINGS Questions Call ADC toll free at 1 800 232 2670 Automatic Blood Pressure Monitor 6021N 6022N 6023N Instruction...

Страница 2: ...ed 9 3 7 Why Measure Blood Pressure at Home 9 3 8 How is Blood Pressure Measured 10 3 9 How Should I Record My Blood Pressure 10 4 COMPONENTS OF YOUR BLOOD PRESSURE MONITOR 11 5 SETTING UP YOUR BLOOD...

Страница 3: ...ink Software Installation and Data Transmission 21 7 2 Installing and Using Microsoft Healthvault 22 8 IRREGULAR HEARTBEAT DETECTOR 23 8 1 Traffic Light Indicator 6023N only 24 9 MEMORY FUNCTION 24 9...

Страница 4: ...e model number of your device look on the rating label located on the underside of the unit Your blood pressure monitor with ADC Averaging Mode Irregular Heartbeat Detection and PC Link Blood Pressure...

Страница 5: ...e best results 2 WARNINGS AND PRECAUTIONS Warning The device contains sensitive electronic components Avoid strong electrical or electromagnetic fields in the direct vicinity of the device e g mobile...

Страница 6: ...There are two components to blood pressure systolic and diastolic pressure Systolic the higher pressure occurs during contraction of the heart Diastolic the lower pressure occurs when the heart is at...

Страница 7: ...octor 3 3 What Influences Blood Pressure Blood pressure is influenced by many factors including age weight physical conditioning past illness time of day altitude activity and climate to name just a f...

Страница 8: ...s often linked with family history and lifestyle This is referred to as essential hypertension In the remaining cases high blood pressure is a symptom of an underlying often treatable condition which...

Страница 9: ...linical studies have shown improved detection and treatment of hypertension when regular home blood pressure monitoring is done in consultation with a physician Blood pressure measured in a doctor s o...

Страница 10: ...d around the limb and inflated to constrict blood flow to the artery As pressure is released from the cuff through the deflation valve blood flow returns to the artery producing pulse beats known as K...

Страница 11: ...Ultra 6023N model PC Link software is available Records can be automatically transferred to your Windows computer Many smart phone and tablet apps allow you to record cart and share your BP measuremen...

Страница 12: ...not pushed into the AC adapter port If the cuff is too small call 1 800 232 2670 for further information You may prefer to use one of our wrist type monitors NOTE If you ever need to buy a replacemen...

Страница 13: ...t that power is available by pressing the 3 ON OFF button NOTE Use only the AC adapter provided with your device ADC is not responsible for the warranty servicing repair of the monitor if any other ad...

Страница 14: ...e date and time are set and the time is displayed NOTE If you want to change date and time press and hold the TIME button down for approx 5 seconds until the user icon flashes Press the TIME button ag...

Страница 15: ...e 1 automatically taken in succession and the result then automatically analyzed and displayed Because your blood pressure constantly fluctuates a result determined in this way is more reliable than o...

Страница 16: ...taken at the same time of day since blood pressure changes during the course of the day as much as 20 40 mmHg 6 2 Common Sources of Error NOTE Comparable blood pressure measurements always require the...

Страница 17: ...our upper arm Wrap the cuff around your upper left arm b The rubber tube should be on the inside of your arm extending downward to your hand Make certain the cuff lies approximately 1 2 3 4 1 2 cm abo...

Страница 18: ...ff should fall between the 2 range lines e There should be little free space between the arm and the cuff You should be able to fit 2 fingers between your arm and the cuff Clothing must not restrict t...

Страница 19: ...lse rate now appear in the display The appearance of this symbol signifies that an irregular 5 heartbeat was detected This indicator is only a caution It is important that you be relaxed remain still...

Страница 20: ...surements used in the measurement 6 6 Reading Measurement Results When the measurement has been concluded a long beep tone sounds The measured systolic and diastolic blood pressure values as well as t...

Страница 21: ...The LCD will display the moon icon After 30 seconds the LCD will display the last taken value for that user 4 Pressing the MEMORY button continuously enables you to 5 view each value individually 7 SO...

Страница 22: ...tible with the Microsoft HealthVault software application HealthVault allows you to easily store use and share your health information online and on your mobile devices To use HealthVault with your un...

Страница 23: ...pletely remove the PC Link software before installing HealthVault HealthVault has a mobile app available in both the Apple App Store and Microsoft Windows Phone marketplace NOTE The Morning Evening Hy...

Страница 24: ...value is either within the normal green borderline yellow or danger red range The classification is based on standards adopted from the WHO World Health Organization Refer to the chart to the right fo...

Страница 25: ...esult of the measurement Further information Measurements should not occur soon after each other otherwise the results will be skewed Wait for several minutes in a relaxed position sitting or lying be...

Страница 26: ...olic pressure was determined but then the pressure in the cuff went down to less than 20 mmHg diastolic blood pressure can t be measured The tube may have loosened after the systolic pressure has been...

Страница 27: ...stallation polarity 2 Remove the batteries and if the display is unusual then exchange them for new ones Check the connection of the cuff tube and connect properly 1 Fit the cuff correctly on the arm...

Страница 28: ...er attempt to repair the instrument yourself Any unauthorized opening of the instrument invalidates all warranty claims 11 CARE AND MAINTENANCE Do not expose the device to either extreme temperatures...

Страница 29: ...rmination Blood Pressure SYS 60 255mmHg DIA 40 200mmHg 40 200 beats per minute pulse Cuff pressure display range 0 299 mmHg Memory Automatically stores the last 99 measurements for 2 users 198 total M...

Страница 30: ...ean and United States standards for non invasive blood pressure monitors EN1060 1 1995 EN1060 3 1997 EN1060 4 2004 Electromagnetic compatibility Device fulfills the stipulations of the International s...

Страница 31: ...about our products and services visit us at www adctoday com and follow the links For questions comments or suggestions call us toll free at 1 800 232 2670 American Diagnostic Corporation 55 Commerce...

Страница 32: ...273 9659 www adctoday com email info adctoday com Read instructions carefully before using this device Type BF applied part ONBO Electronic Shenzhen Co Ltd No 497 Ta Laneg Nan Road Ta Laneg Street Ba...

Отзывы: