1. set Up Before Use
1.1 electrical Connection
The luminaire is suitable for operation on standard 50 Hz,
230 V to 250 V star type electrical supplies with Phase, Neutral
and Earth connections. It is delivered with a cable HO7-RNF
3 x 1.5 mm
2
2 m length, equipped with a EEC 22 at the luminaire
site.
in use, take care to move away the cable from the hot parts
of the luminaire.
Use
iMpeRAtivelY
this cable with your luminaire.
For your own safety, make sure the earth wire (yellow-green)
is AlWAYs connected to earth.
With a 13 Amp plugtop a 3 Amp HRC BS1362 fuse should be
fitted in the plugtop. Fuses of a higher rating will not provide the
correct degree of cable or instrument protection.
For other countries customers may fit their own plug tops, please
follow the wiring code listed below:
Brown
Live Supply.
Blue
Neutral Supply
Green/Yellow
Earth Connection
1.2 Fitting lamps
Prior to using the luminaire the correct fluorescent tubes should be inserted into the luminaire.
AlWAYs isolAte FRoM the MAins sUpplY BeFoRe AtteMptinG to Fit lAMps.
Unpack the lamps from their cartons,
first
insert the lamp into the retaining clips,
then
gently
push the lamp into the G11 lampholder. The units are designed to enable them to be moved
around with the lamps fitted, always providing care is taken when moving them. Transport cases
are available for ENG and rental applications.
Содержание SOFTLUX
Страница 2: ...SOFTLUX Cool Lights Manual page 2 I s s u e 0 0 3 Lighting Technologies ...
Страница 13: ...Manual page 13 I s s u e 0 0 3 SOFTLUX Cool Lights Lighting Technologies Notes ...
Страница 14: ...SOFTLUX Cool Lights Manual page 14 I s s u e 0 0 3 Lighting Technologies 10 EC declaration of conformity ...
Страница 15: ...Manual page 15 I s s u e 0 0 3 SOFTLUX Cool Lights Lighting Technologies ...