2.5.2 Maintenance
Procedures
This section provides instructions for replacing lamps for the L-861SE threshold/end light
fixture.
To replace a lamp, perform the following procedure:
1. See Figure 5. Remove the outer globe (H2) from the fixture by loosening the clamp band
holding the lens to the base.
2. Remove the two inner lens segments (H1R/L) by pulling and sliding off the inner spring
clip (H3) and the Inner Lens Clip (C1).
3. Pull the lamp (L1) from the socket (S1).
4. Wearing clean, lint-free gloves, insert the new 2-pin lamp into the lamp socket.
5. Reinstall the inner lens segments and outer lens by reversing the removal procedure.
6. Reinstall the outer lens.
7. Clamp the latch on the outer lens.
WARNING
De-energize the circuit and lock out the circuit or regulator so that the
circuit cannot be energized by remote means before attempting to service
the fixture.
• Failure to observe a warning may result in personal injury, death or
equipment damage.
CAUTION
Touching quartz lamps with bare fingers may seriously shorten lamp life.
If the quartz lamp has been touched, clean the lamp with tissue moistened
with isopropyl alcohol.