6. THEATRICAL MEMORIES
6.1 OVERVIEW
A
Theatrical Memory List
is a recorded list of memories. Minimum 500 memories may be
recorded in
Theatrical Memory List
. Fading from one memory to the next done by a dipless
X- fade. The X-fade is usually executed automatic but can be manually.
6.2 RECORDING THEATRICAL MEMORY
To record a
theatrical memory
, create the desired look on the output, then press [
record
memory
].
The Record memory button flashes and the display scrolls “
Pick memory Number
” and
stops on the next memory number available. (E.g. M 017). The OK button and Function
button flash to show that they are active. The
theatrical memory
number can be changed by
the use of the wheel. The indication
M 024
indicates empty
theatrical memory
,
M:024
indicate used
theatrical memory
. Pressing
[OK]
will
record the current output
to the
theatrical memory
indicated on the display. If the selected
theatrical memory
has already
been used, the display will read “WARNING memory exists – overwrite?” You now have two
options.
•
To erase the existing
theatrical memory
and replace it with the current output either
press [
OK
]
•
To pick another
theatrical memory
number use of the wheel and press [OK]
6.2.1
THEATRICAL MEMORIES NUMBERS (AND POINT THEATRICAL
MEMORIES)
Any
theatrical memory
number between 0.1 and 99.9 can be used. To select a point
theatrical memory
number use the [<] and [>] to decrease or increase by 0.1.
6.3 FADE AND LINK TIMES
As each
theatrical memory
is recorded (above) you may set the fade IN and OUT times
Before pressing [
OK
] to record the
theatrical memory
, press [
function
] to cycle through the
fade IN time and fade OUT. When any of the time settings are indicated, rotate the
EDIT
wheel to set the desired time. The maximum time is more than 16 minutes and the minimum
time is 0 seconds. When a time is set
lower
than 0 seconds, it reverts to
rotating speed
fader.
If you do not enter a time then the default settings will be used. The default time is 5 second
for IN and OUT time. (You can change the default times with the “Setup Preferences”
function. See the “UTILITIES” section).
6.3.1
LINK TIMES
If a
theatrical memory
contains a LINK time, then when that
theatrical memory
is played,
its link time starts counting down. At the completion of the link time, the
theatrical memory
list
will automatically step to the next
theatrical memory
. If every
theatrical memory
has a
link time, then the
theatrical memory
list
will play like a chaser, but with the following
differences.
•
The duration of every step may be individually set by its link time.
•
The in and out fade times of every step may be individually set.
Setting link times see chapter below, Editing a
theatrical memory
.