Operation
www.adblighting.com
User Manual - page 5
Issue
2.0
3. Operation
For normal operation, set the DIP switches to the desired configuration and set the rotary
address switch to the desired DMX address. Set power and the unit is now ready to work.
3.1 LED Indicators
LED Description
Red power LED
Red LED lights up when DC power is applied to
the unit.
Green signal LED
Green LED lights up when the unit receives
proper DMX signal.
It flashes at short «ON», long «OFF» interval
when the gel string breaks.
It flashes at short «OFF», long «ON» interval
when the motor is jammed
3.2 TEST Button
This switch button is used to test the unit. When used together with the DIP switches and
address switches, it sets the different operation modes available. After replacing the colour
filter (gel string) roller or adjusting a wrongly positioned gel string, press this button to RESET
the unit. The gel string will then scroll to the starting end, then to the other end, and finally
back to the starting end again, stopping at the control signal position.
3.3 Rotary address switch
For DMX operation, it is necessary to set the address of each colour changer to match the
dimmer number set on the control console. The address can be set between 1 to 512, by
means of the 3 rotary switches (X100, X10&X1).