background image

 

953.058UK User Manual 

 

Caution: Please read this manual carefully before operating 

Damage caused by misuse is not covered by the warranty 

 

Introduction 

 

Thank you for choosing an Adastra DP-8 digital power schedule controller for power automation of installed sound, lighting and service 
equipment. This unit is designed to provide flexible scheduling and automation of 8 power outlets, fully programmable by the operator. 

Please read this manual to gain the best results from your product and avoid damage through misuse. 
 

SAFETY SYMBOL AND MESSAGE CONVENTIONS 

 

 

CAUTION 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN 

AVIS 

RISQUE DE CHOC ELECTRIQUE NE PAS 

OUVRIR 

 

 

 

 

 

 

This symbol indicates that dangerous voltage constituting a risk of electric shock is 

present within this unit

 

 

 

 

This symbol indicates that there are important operating and maintenance instructions in 

the literature accompanying this unit.

 

 

 

SAFETY NOTICE 

 

1.

 

Prior to use, read through this manual

 

2.

 

Keep the manual in good condition 

3.

 

Pay attention to safety warnings 

4.

 

Observe all operating requirements 

5.

 

Do not use the device near water or wet areas 

6.

 

For cleaning, only use a lint-free, dry cloth 

7.

 

Install according to the specifications 

8.

 

Place away from heat sources or heating appliances 

9.

 

Use mains lead provided and avoid damage to cable or connectors 

10.

 

Unplug power from mains during stormy weather or if unused for long periods 

11.

 

In case of malfunction, water ingress or other damage, consult qualified service personnel 

12.

 

Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing 

13.

 

Please pay attention to warning symbols during transit and placement 

14.

 

Terminals marked with the   symbol are HAZARDOUS LIVE and should only be connected by qualified personnel 

15.

 

Ensure that the apparatus is connected to a mains socket with a protective EARTH connection 

16.

 

Ensure correct operation of the mains switch 

 

 
Note: 

This equipment is designed to be wired directly to mains power and should be installed by a qualified electrical engineer.  

The unit is hard-wired with a 36A mains cable.  
If a domestic plug is connected to this, the rating may be reduced. 

 

Warning 

 

 

To prevent the risk of fire or electric shock, do not expose any components to rain or moisture. 

 

If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before 

further use.  

 

Avoid impact, extreme pressure or heavy vibration to the case 

 

No user serviceable parts inside 

 Do not open the case 

 refer all servicing to qualified service personnel. 

 

Placement 

 

 

This unit can be used free-

standing or fixed into a 19” rack

 

 

Ensure adequate support and access to controls and connectors when rack-mounting 

 

Cleaning 

 

 

Use a soft cloth with a neutral detergent to clean the housing as required 

 

Do not use strong solvents for cleaning the unit 

 

Содержание DP-8

Страница 1: ...DP 8 DIGITAL POWER SCHEDULE CONTROLLER Item ref 953 058UK User Manual Version 1 0 ...

Страница 2: ...ower from mains during stormy weather or if unused for long periods 11 In case of malfunction water ingress or other damage consult qualified service personnel 12 Do not place in damp areas or near liquids or moisture Do not spill liquids on the housing 13 Please pay attention to warning symbols during transit and placement 14 Terminals marked with the symbol are HAZARDOUS LIVE and should only be ...

Страница 3: ... sure that the total current load will not exceed the fuse or breaker if all IEC outputs are activated at the same time If more than one single appliance is to be powered from any of the IEC outlets a splitter or distribution block may be used so long as the combined load on the individual IEC outlet is less than 10A For very high power configurations any of the IEC outputs can be used to remotely...

Страница 4: ...ge and current values The display is backlit which dims after approximately 40 seconds if there are no buttons pressed The 8 output channels can be operated manually by switching any of the front panel buttons 6 on or off this will not be effective if any channels are set to be always on as detailed in the Bypass setting section Press and hold the Settings Display button 2 to change the display to...

Страница 5: ...m value it cannot be saved Once the values are set press the Enter button to save the settings or ESC to exit without saving Note if the current exceeds 32A or if there is a short circuit the main circuit breaker will trip Timing program The DP 8 timing program enables the installer to program a schedule for one or more of the IEC outputs to be switched on or off There are 99 internal events which...

Страница 6: ...hen press Enter Set the ID number using the buttons 8 and press Enter again to confirm Bypass The Bypass setting enables the user to select which channels are set to always on bypassing manual or timer control From the settings menu step through the options until BYPASS is displayed and then press Enter Set the channel buttons 6 on for channels which are to be always on regardless of timer or manu...

Страница 7: ...outlets Connections USB port RS485 12Vdc out remote GND Status Dimensions 482 x 250 x 44mm Weight 3 0kg Disposal The Crossed Wheelie Bin symbol on the product means that the product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life The goods must be disposed of according to your local council guideline...

Отзывы: