30
Vibrations in frequency ranges – gearbox/bearing
Measurement of RMS vibration values in the ranges:
0.5 kHz - 1.5 kHz in g,
1.5 kHz - 5 kHz in g,
5 kHz - 16 kHz in g.
FASIT expert system
The FASIT screen displays the severity levels of machine faults. Also the temperature bar is displayed
on the right side.
When the RPM is not found then no results are displayed (from ver.2.05).
Overall RMS and Peak displacement values in the range 2-100 Hz in mm.
From ver.2.05 is the displacement displayed in um.