![Adaptivation VoicePal Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/adaptivation/voicepal/voicepal_instructions-manual_2846954015.webp)
29
Step#
Action to Take
Result
Step 1
Plug an ECU into Relay A and ECU into the radio.
Step 2
Note current settings of
SW2 through SW6.
Step 3
Set SW1= OFF
Places Max in Setup state.
Step 4
Clear Relays
Step 5
Set SW2 through SW6=
Sets Relay A for 0 second
OFF ON ON OFF ON
delay.
Step 6
Press button 1.
Attaches Relay A to message
Record LED will flash.
1.
Step 7
Set SW2 through SW6=
Sets Relay A for a 4 second
OFF ON OFF OFF ON
delay.
Step 8
Press button #2.
Attaches Relay A to message
Record LED will flash.
2.
Step 9
Set SW1= ON
Places Max in Active state.
Step 10
Return SW2 through SW6
to previous settings.
When message 1 is activated, the message will
play, then Relay A will activate the ECU turning the
radio on. When message 2 is activated, the message will
play, then four seconds after the message is over Relay A
will activate the ECU turning the radio on. From this
example, you can see one relay can be assigned to two
different messages.
Example 12: Program message 4 to turn on an
adapted toy using a switch latch timer box (e.g.
Adaptivation’s Linkswitch) with a six second delay.
Step#
Action to Take
Result
Step 1
Plug the Switch latch timer into Relay B and also the
adapted
toy.
Step 2
Note the current settings of
SW2 through SW6.
Step 3
Set SW1= OFF
Places Max in Setup state.
Step 4
Clear previous relays.
Step 5
Set SW2 through SW6=
Sets Relay B for 6 second
30
ON OFF OFF OFF ON
delay.
Step 6
Press button #4.
Attaches Relay B to message
Record LED will flash.
4.
Step 7
Set SW1= ON
Places Max in Active state.
Step 8
Return SW2 through SW6
to previous settings.
When message 4 is selected, the message will play
and 6 seconds later Relay B will activate the switch latch
timer and the toy.
F
ACTORY
S
ETTINGS
The factory defaults are as follows:
-Visual scan rate: 1 second per message.
-Standard Auditory Scanning
-Interauditory pause: 1 second
-Scan cycle mode: Stop scanning after message selected
-Inactivity shutdown: Repeat scan four times.
You may program as many of the features de-
scribed at a time as you wish. When the batteries are
removed, all options programmed in the Setup state will
revert to factory defaults. Any recorded messages will
not be lost.
E
XTERNAL
S
PEAKER
J
ACK
This jack will allow you to plug in an additional
speaker. This may be an amplified speaker for situations
when a very loud volume is needed, or a set of head-
phones when a quiet message is needed. The VoicePal
Max's internal speaker will automatically shut off when
an external speaker is used.