4-8
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
describes the status LEDs for this example.
Table 4-4 Drive Status LEDs – One-Touch Annunciation Example
Drive Slot
Status LED
Description
1
On
Enclosure is in dual-bus mode.
2
On
SCSI host interface.
3
Off
N/A
4
Off
Switch 1 (A0) is in the DOWN position. This
sets the drive SCSI IDs of the slots to IDs 1, 2,
3, 4, 5, 6, 9, 10, 11, 12, 13, 14. It reserves IDs 0
and 7 for the host bus adapter, and SCSI ID
15 for the SAF-TE processor.
5
Off
Switch 6 is in the DOWN position. This sets
the BAUD rate for the SAF-TE RS-232 serial
port to 9,600.
6
Off
N/A
7
Off
Switch 2 (A1) is in the DOWN position. This
sets the drive SCSI IDs of the slots to IDs 1, 2,
3, 4, 5, 6, 9, 10, 11, 12, 13, 14. It reserves IDs 0
and 7 for the host bus adapter, and SCSI ID
15 for the SAF-TE processor.
8
On
Switch 7 is in the UP position. This sets the
Delay Start mode to Disabled.
9
On
Controller is present.
10
On
Switch 3 (RD) is in the UP position. This
enables RAID addressing and is used when
configuring RAID mode (DuraStor 7320SS).
11
On
Switch 8 is in the UP position. This sets the
Remote Start mode to Disabled.
12
On
Controller is present.
DuraStor IUG - Online.book Page 8 Friday, July 19, 2002 3:06 PM