
Appendix E: Using the ICP Flash Utility
●
108
Verify
Compares the contents of each of the flash components on a RAID controller to the
corresponding image in a UFI file, and indicates whether they match. After using the VERIFY
command, you must restart the computer.
The command syntax for the VERIFY command is as follows:
IFU VERIFY [/C<Controller ID>] [/D <UFI File Path>]
This example shows a typical system response after a VERIFY command.
A:\> IFU VERIFY /C 0
ICP Flash Utility V4.0-0 B5749
(c)ICP Inc. 1999–2005. All Rights Reserved.
Reading flash image file (Build 5748)
Controller #0: ICP ICP9087MA
ROM: Checksum: 797B [VALID] (Build 5748)
File: Checksum: 797B [VALID] (Build 5748)
Image Compares Correctly
Version
Displays version information about the flash components on a RAID controller. After using
the VERSION command, restart your computer.
The command syntax for the VERSION command is:
IFU VERSION [/C<Controller ID>]
This example displays version information about all supported RAID controllers.
A:\> IFU VERSION /C 0
ICP Flash Utility V4.0-0 B5749
(c)ICP Inc. 1999–2005. All Rights Reserved.
Version Information for Controller #0 (ICP ICP9087MA)
ROM: Build 5748 [VALID] Fri Sep 27 13:28:40 EDT 2005
A:\> IFU VERSION /C ALL
Help
Displays a summary of IFU functions and command switches. For example:
A:\> IFU HELP
A:\> IFU /?