ADE- 2022-C
Page 30 of 50
24.2
24.2
24.2
24.2 Settings for Dixell XB570L Blast C
Settings for Dixell XB570L Blast C
Settings for Dixell XB570L Blast C
Settings for Dixell XB570L Blast Chill Controller
hill Controller
hill Controller
hill Controller
Variable
Variable
Variable
Variable
Value
Value
Value
Value
Units
Units
Units
Units
Description
Description
Description
Description
Set point -21
Hy
1
Hysteresis
tCy
Read
only
Cycle duration
Pr1
Pr1
Pr1
Pr1
tP1
Read
only
First phase duration
tP2
Read
only
Second phase duration
tP3
Read
only
Third phase duration
Pr2
Pr2
Pr2
Pr2
Installer parameters
PAS
321
Pass code
Parameters
Parameters
Parameters
Parameters
Hy
1
Hysteresis
AC
1
Anti-short cycle
PAU
0
Time of standby
PFt
15
Maximum acceptable duration of power
failure
Con
15
Compressor on time with faulty probe
COF
15
Compressor off time with faulty probe
Probes
Probes
Probes
Probes
rPO
0
Thermostat probe calibration
EPP
Yes
Evaporator probe presence
EPO
0
Evaporator probe calibration
i1P
Yes
Insert probe 1 presence
i1O
0
Insert probe 1 calibration
i2P
No
Insert probe 2 presence
i2O
0
Insert probe 2 calibration
i3P
No
Insert probe 2 presence
i3O
0
Insert probe 2 calibration
rEM
rPt
Probe selection to stop chilling cycle
Display and measurement unit
Display and measurement unit
Display and measurement unit
Display and measurement unit
CF
°C
Temperature measurement units
rES
dE
Resolution
Lod
rP
Local display
rEd
rP
Remote display