background image

EN

FAC-SIMILE

FAC-SIMILE

ADAM PUMPS Spa
Via della Resistenza 48
41011 Campogalliano
Modena Italy

2 0 1 6

J A N

Code : PB0852000

PUMP PB 12V-85

12 Volt - 440W - 36 A - 2600 rpm

 

Weight Kg.: 7.5

Batch of

Model

Description

Technical specifications

Weight

EC DECLARATION OF CONFORMITY

(Annex II A DIR. 2006/42/EC)

THE MANUFACTURER

ADAM PUMPS S.p.A., with its registered office in Via della Resistenza, 46/48, 41011, Campogalliano (MO), ITALY; represented by 

Davide Stassi, authorised to compile the relevant technical file at the undersigned premises,

DECLARES THAT THE MACHINE

Used as a diesel fuel pump to be integrated into a system for transferring fuel from a gravity tank.

COMPLIES WITH DIRECTIVES

Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC.
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member 
States relating to electromagnetic compatibility.
Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the 
Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits. 

Applicable only for AC powered products.

the use and maintenance manual must be carefully stored near the machine in an environment protected against 

humidity and heat. The manual must accompany the machine if sold. It is prohibited to damage, modify or remove any 

part of the manual.

USE AND MAINTENANCE MANUAL

Machine

:   DIESEL FUEL PUMP

Models

:  

PB 50, PB1 50 (12-24V), PB 60, PB1 60 (12-24V),

 

PB 85, PB1 85 (12-24V)

Place and date of the document

Campogalliano, January 14, 2020

The legal representative

TABLE OF CONTENTS

1 - GENERAL WARNINGS

2 - MACHINE SPECIFICATIONS
2.1 Intended use
2.2 Description of the machine
2.3 Technical specifications
3 - OPERATING CONDITIONS
3.1 Environmental conditions3.2 Power supply3.3 
Allowed fluids / Forbidden fluids
4 - TRANSPORT AND HANDLING

4.1 Transport
4.2 Unpacking
4.3 Storage

5 - INSTALLATION
5.1 Preliminary checks and positioning the pump
5.2 Hydraulic pipe connection
5.3 Remarks on the suction and discharge lines
5.4 Electrical connection of the pump
6 - INTENDED USE
6.1 Preliminary checks and start-up

6.2 Daily use
6.3 Noise level
6.4 Compatibility in an electromagnetic environment

7 - TROUBLESHOOTING

8 - MAINTENANCE
9 - DEMOLITION AND DISPOSAL

10 - WARRANTY
11 - TECHNICAL SUPPORT

Содержание PB 50

Страница 1: ... 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM032 7 2020 rev 6 PB 50 PB1 50 12 24V PB 60 PB1 60 12 24V PB 85 PB1 85 12 24V ITALIANO lingua originale ENGLISH translation of original instructions IT EN ...

Страница 2: ...ember States relating to the making available on the market of electrical equipment designed for use within certain voltage limits Applicable only for AC powered products the use and maintenance manual must be carefully stored near the machine in an environment protected against humidityandheat Themanualmustaccompanythemachineifsold Itisprohibitedtodamage modifyorremoveany part of the manual USE A...

Страница 3: ... 40 PB1 85 12 V 12V DC 40 480 S2 30 min 85 1 1 70 40 PB 85 24 V 24V DC 32 768 S2 30 min 93 1 1 74 40 PB1 85 24 V 24V DC 32 768 S2 30 min 93 1 1 74 40 IMPORTANT It is essential to have understood the entire instruction manual before perfor ming any operation so as to safeguard operator safety and to avoid potential product damage Storing the manual This manual must be kept intact and fully legible ...

Страница 4: ... the same diameter or a diameter larger than the minimum specified in chapter 3 INSTAL LATION always keep the filter inside the pump clean and regularly inspected 4 3 Storage Prior to its use the pump still in its original packaging should be stored in a dry and protected place in an environment with the conditions described in Section 2 1 Environmental conditions Failure to follow these instructi...

Страница 5: ...itable for operation under negative pressure 5 3 Remarks on the suction lines SUCTION LINE The electric pumps in this manual are self priming and can draw the liquid from a maximum height of 2 metres Caution proper priming and the time required for this can be affected by an automatic nozzle on the discharge line which prevents normal air extraction from the pipe It is therefore always advisable t...

Страница 6: ... and components on the hydraulic line are in good condition and properly sealed and the nozzle is closed the pump can be started After inserting the nozzle into the filling hole switch the pump on gradually release the nozzle lever and start transferring the diesel fuel When you have finished filling close the nozzle and switch the pump off If you are using an automatic nozzle it will automaticall...

Страница 7: ...ed to operate correctly in an industrial electromagnetic environment and staying within the Emission and Immunity limits laid down in the following Harmonised Standards IEC EN 61000 6 2 Electromagnetic compatibility EMC Generic standards Immunity for industrial environments IEC EN 61000 6 4 Electromagnetic compatibility EMC Generic standards Emission standard for industrial environments 7 TROUBLES...

Страница 8: ... and clean or replace it if necessary Vanes blocked Check and clean the vanes and their housings Excessive wear of the vanes or impeller Replace the worn components Leaks from the gaskets Make sure the gaskets are properly tightened and not worn Incorrect power supply voltage Power the pump as specified on the rating plate Defective motor Contact the dealer fault code M2 9 DEMOLITION AND DISPOSAL ...

Страница 9: ...mpered with The product is used in an area with power supply defects voltage changes current phase shift etc The product is used without the supplied suction filter inside or outside the pump Immediately excluded from the warranty are adhesive labels plastic and metal casing keyboards and masks components subject to wear such as blades impellers graphite brushes where present in the motors seals a...

Страница 10: ... PA018 SWIVEL LOCKING PLATE 1 15 11010040200 11010040200 O RING 2015 NBR 1 12V 24V DESCRIPTION QTY 16 82301410100 82301410100 SCREW TC M4 X 8 2 17 VT004 VT004 SCREW TC Ø3 5X16 4 18 12010031000 12010031000 SHAFT SEAL Ø19 1 19 VT046 VT046 SCREW TE M5X12 5 20 OR039 OR039 O RING NBR70 57X2 1 21 OR037 OR037 FILTER SEAL 1 22 17001108 17001108 4M CABLE WITH CLAMPS 1 23 61004600000 61004600000 TIE ROD M5 ...

Страница 11: ... 11 53019030 CABLE GLAND NUT GMP GL 13 5 1 12 83101810000 PLATE WASHER 5x10x1 UNI 6592 2 13 82021810000 SELF LOCKING NUT M5 UNI 7473 2 14 190050210000 SWITCH 22X30 COVER 1 CODE DESCRIPTION QTY 15 PA018 SWIVEL LOCKING PLATE 1 16 VT046 SCREW TE M5X12 FLANGED UNI5541 5 17 11010040200 O Ring 2015 NBR 1 18 71000520 BY PASS VALVE 1 19 61000003 ROTOR Ø45 1 20 71000522 SMALL VANE 5 21 17001097 PIN 3x3x15 ...

Страница 12: ...E Ø5X135 2 8 VT022 HEX SPACER MF M5X25 2 9 PB001 MOTOR COVER IP55 1 10 53015030 CABLE GLAND 1 11 53019030 CABLE GLAND NUT 1 12 83101817100 PLATE WASHER Ø5 2 13 82021810000 SELF LOCKING NUT M5 2 14 190050210000 SWITCH 22X30 COVER 1 CODE DESCRIPTION QTY 15 PA018 SWIVEL LOCKING PLATE 1 16 VT046 SCREW TE M5X12 FLANGED 5 17 11010040200 O Ring 2015 NBR 1 18 71000520 BY PASS VALVE 1 19 61000003 ROTOR Ø45...

Отзывы: