background image

© Adam Equipment Company 2007

 

6

5.0 CBK-M 

DESCRIPTION 

 

The CBK-M scales have an enclosure with all components mounted within it. To gain 

access to the components remove the 5 screws securing the cover to the base. 

 

The basic unit consists of: 

 

9

 Base 

9

  Load Cell frame 

9

 Power switch 

9

 Main PCB assembly 

9

 Battery 

9

  Display PCB assembly 

9

 Keypad  

 

All models of CBK-M are similar except the selection of load cells and the program. 

 

Normally if a problem is found with a circuit board the most cost effective method of 

solving the problem is to replace the circuit board.  

 

The main PCB assembly includes:  

 

9

  A/D converter (AU1),   

9

  Microprocessor (DU1) and   

9

 Power 

supply/battery 

charger 

circuits (DU5, T2).     

 

6.0  LOAD CELL DAMAGE 

The most common reason why a scale fails is that the load cell has been damaged.  The 

damage can be from 2 primary causes.  The first is physical damage due to an overload or 

an impact from the side and the second is damage due to the environment, such as 

moisture, extreme heat or a cut cable if the cables are exposed. 

 

PRINCIPLE OF OPERATION 

 

The stain gauge load cell is a method of measuring the amount of stress put onto a metal 

structure due to a weight being supported by the structure.  The stress is measured using 

4 strain gauge sensors mounted in a particular way on the metal structure.   

 

These 4 strain gauges are connected in such a way that they form a Wheatstone Bridge.  

See figure below.  In the simplest load cells there are only the 4 resistances of the strain 

Содержание CBK 6M

Страница 1: ...Adam Equipment CBK M SERIES Service Manual Software rev 4 07 above ADAM EQUIPMENT CO LTD P N 9017 Rev A2 July 2007 Adam Equipment Company 2007...

Страница 2: ...Adam Equipment Company 2007...

Страница 3: ...MAGE 6 7 0 CALIBRATION 9 7 1 SECURITY SEALS 10 7 2 CALIBRATION PROCEDURE 10 8 0 FACTORY PARAMETERS 11 8 1 F1 CALIBRATION 12 8 2 F2 RESOLUTION 13 8 3 F3 CAPACITY 13 8 4 F4 INITIAL ZERO RANGE 13 8 5 F5...

Страница 4: ...he scales have stainless steel weighing platforms on an ABS base assembly All scales are supplied with a RS 232 bi directional interface and real time clock RTC NOTE For Approved applications CBK M Sc...

Страница 5: ...ating Temperature 10 C to 40 C 14 F to 104 F Power supply 115 230 VAC Mains 50 60 Hz or 9 VDC 800 mA through an external adapter Battery Internal rechargeable battery 90 hours operation Calibration No...

Страница 6: ...struction under pan Sample is moving animal weighing Vibrations through table Temperature changed dramatically Electronics faulty or Battery low Weight value incorrect Calibration error Recalibrate Un...

Страница 7: ...e pan when zeroing the scale Platform is not installed Improper calibration of the scale Damaged load cell Damaged Electronics Err 6 A D count is not correct when turning the scale on Load cell is dam...

Страница 8: ...d 9 Power supply battery charger circuits DU5 T2 6 0 LOAD CELL DAMAGE The most common reason why a scale fails is that the load cell has been damaged The damage can be from 2 primary causes The first...

Страница 9: ...THE LOAD CELL 10 VOLT POWER SUPPLY Vout 0 028 VOLTS 28mv BETWEEN S AND s This will cause the bridge to become unbalanced When the bridge has a voltage across it from E to E then the signal output at...

Страница 10: ...ween S and S With no load the voltage should be approximate 0mv 3mv With a mass on the load cell the output voltage should increase The amount by which it increases will be dependent upon the sensitiv...

Страница 11: ...ifier IC This voltage is sent to the filter and then to the A D converter 7 0 CALIBRATION The CBK M Scales are sealed to prevent unauthorised calibration The calibration of the CBK M scale is accompli...

Страница 12: ...the base and cover If this seal is broken the scale must be sealed by the relevant authorities using either the lead wire seal or an acceptable seal between the cover and base 7 2 CALIBRATION PROCEDUR...

Страница 13: ...le to access the PCB Place a jumper through the hole into the pins If a jumper is not available short the pins Turn on the scale using the switch on the base P _ _ _ _ Enter 2006 and press Tare After...

Страница 14: ...CAP Select Capacity F4 int Initial Zero Range F5 rE Z Re Zero Range F6 SCS Successive Tare Enable F7 Cnt Display the A D counts F8 ZE M Set zero method F9 Ld M Set low voltage detect mode 8 1 F1 CALI...

Страница 15: ...he options Press Tare to accept the displayed value and return to the parameter or press the Zero key to return to the parameter without changing the value Then press Func to advance to the next param...

Страница 16: ...e options Press Tare to accept the displayed value and return to the parameter or press the Zero key to return to the parameter without changing the value Then press Func to advance to the next parame...

Страница 17: ...000 90 000 approx Typical value at full capacity is 500 000 approx 8 8 F8 ZERO This parameter allows the normal method of setting zero To enter this parameter press the Tare key when F8 ZE M is shown...

Страница 18: ...lue Then press Func to advance to the first parameter Pressing Zero will display JP on indicating the jumper is still in place Switch off the scale and remove the jumper NOTE TO SECURE THE SCALE IT IS...

Страница 19: ...9 0 WIRING DIAGRAM Adam Equipment Company 2007 17...

Страница 20: ...10 0 MECHANICAL ASSEMBLY Adam Equipment Company 2007 18...

Страница 21: ...mpatibilit lectromagn tique This declaration is only valid when accompanied by a Certificate of Conformity issued by a Notified Body Diese Erkl rung gilt nur in Verbindung mit einer Konformit tsbesche...

Страница 22: ...edical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of...

Отзывы: