background image

 

 

Adam Equipment

 

ADAM EQUIPMENT,  BOND AVENUE, DENBIGH EAST INDUSTRIAL ESTATE,  

MILTON KEYNES, MK1  1SW, U.K. 

Tel: (01908) 274545                  Fax: (01908) 641339     

 

Intl Tel:   -44 1908 -274545         Intl Fax: -44 1908 641339 

E-Mail Address[email protected]

 
 

 
 

Declaration of Conformity               Verklaring van overeenstemming 
Konformitätserklärung                     Dichiarazione di Conformità 
Déclaration de Conformité              Declaración de Conformidad

 

 
The non-automatic weighing instrument                                                           Het niet –automatische weegwerktuig 
Die nicht- automatischen Wägeapparate  

 

                         Strumento per pesatura non automatico  

L’instrument de pesage à fonctionnement non automatique                            Imstrumento para pesaje non automatico  

 
Manufacturer : 
 

Adam Equipment Co. 

Ltd. 

Hersteller : 
 

Adam Equipment Co. Ltd. 

Fabricant : 

Adam Equipment Co. Ltd. 

Type: CBK-M 

Typ: 

CBK-M 

Type: 

CBK-M 

No of the EC 
type-approval 
certificate: 
 

T7249/TC7248 

Nr. der EG-
Bauartzulassung: 
 

T7249/TC7248 

N˚ du certificate 
d’ approbation CE 
de type: 

T7249/TC7248 

Corresponds to the production model 
described in the EC type-approval certificate 
and to the requirements of the Council 
Directive 90/384/EEC as amended and to 
the requirements of the following EC 
Directives: 

Entspricht dem in der Bescheinigung über die 
Bauartzulassung beschriebenen Baumuster, sowie 
den Anforderungen der EG-Richtlinie 90/384/EWG 
in der jeweils geltenden  Fassung und den 
Anforderungen folgender EG-Richtlinien: 

Correspond au modèle décrit dans le certificat 
d’approbation CE de type, aux exigences de la 
directive 90/384/CEE modifiée et aux exigences 
des directives CE suivantes: 
 

73/23/EEC Electrical 

equipment 

for use within certain 
voltage limits (Low 
Voltage Directive) 

73/23/EWG 

Elektrische Betriebsmittel zur 
Verwendung innerhalb 
bestimmter Spannungsgrenzen 
(Niederspannungsrichtlinie) 

73/23/CEE 

Matériel électrique pour 
utilisation dans des limites 
de tension définies 
(Directive Basse Tension) 

89/336/EEC Electromagnetic 

compatibility 

89/336/EWG Elektromagnetische 

Verträglichkeit 

89/336/CEE Compatibilité 

électromagnétique 

This declaration is only valid when 
accompanied by a Certificate of Conformity 
issued by a Notified Body. 

 

Diese Erklärung gilt nur in Verbindung mit einer 
Konformitätsbescheinigung einer benannten Stelle 

 

Cette déclaration est seulement valide quand elle 
est accompagnée par une Attestation de 
Conformité délivrée par un Organisme Notifié. 

 

Fabrikant : 
 

Adam Equipment 

Co. Ltd. 

Produttore 

Adam Equipment Co. 

Ltd. 

Fabricante 

Adam Equipment Co. Ltd. 

Type: CBK-M 

Modello:  CBK-M 

Tipo:  CBK-M 

Nummer van de 
Verklarling van 
EG-
typegoedkeuring 

T7249/TC7248 

N. di certificato di 
approvazione di tipo 
CE 

T7249/TC7248 

Numaro del 
certificado de 
aprobacion de tipo 
CE: 

T7249/TC7248 

Conform met het model beschreven in de 
verklaring van EG-typegoedkeuring en met 
de voorschriften van EG richtlijn 
90/384/EEC zoals gewijzigd en met de 
volgende EG richtlijnen: 

Conforme al modello di produzione descritto nel 
certificato di approvazione de tipo CE e secondo le 
richieste CE direttivo 90/384/CEE come modificato 
e secondo le rechieste della seguente directive CE 

Conforme al modello di producion descrito nel 
certificado di aprobacion del tipo CE e segun los 
requisitos del CE diretiva 90/384/CEE como 
modificato e segun los requisitos della siguiente 
diretive CE 

73/23/EEC Laagspanning 

richtlijn 

73/23/EWG 

Strumenti elettrici per uso 
entro certi limiti di 
voltaggio ( Directivo di 
voltaggio basso) 

73/23/CEE Instrumentos 

electricos 

para uso dentro cierti 
limites del voltaje 
(Diretivo di voltaje bajo) 

89/336/EEC EMC 

richtlijn 

89/336/EWG 

Compatibilita 
electromagnetico 

89/336/CEE Compatibilidad 

electromagnetico 

Deze verklaring is alleen geldig samen met 
een certificaat van overeenstemming 

 

afgegeven door een bevoegde instantie. 

 

Questa dichiarazione e valida solamente se 
accompagniato da un certificato di conformita 
relaciato da un ente riconosciuto. 

 

Esta declaracion es valida solamente si 
accompagniato a un certificado da conformidad 
emitida par un organismo notificado. 

 

Signature    

 

 

 

 

 

Date 

Unterschrift 

 

 

 

 

 

 

Datum 

Signature 

       Date 

 19 

July 

2007 

Handtekening 

 

 

 

 

 

 

Datum 

Firma 

 

 

 

 

 

 

 

Date 

Firma 

 

 

 

 

 

 

 

Fache 

 

 

 

 

 

J.S. Cumbach 

 

© Adam Equipment Company 2007

 

Содержание CBK 6M

Страница 1: ...Adam Equipment CBK M SERIES Service Manual Software rev 4 07 above ADAM EQUIPMENT CO LTD P N 9017 Rev A2 July 2007 Adam Equipment Company 2007...

Страница 2: ...Adam Equipment Company 2007...

Страница 3: ...MAGE 6 7 0 CALIBRATION 9 7 1 SECURITY SEALS 10 7 2 CALIBRATION PROCEDURE 10 8 0 FACTORY PARAMETERS 11 8 1 F1 CALIBRATION 12 8 2 F2 RESOLUTION 13 8 3 F3 CAPACITY 13 8 4 F4 INITIAL ZERO RANGE 13 8 5 F5...

Страница 4: ...he scales have stainless steel weighing platforms on an ABS base assembly All scales are supplied with a RS 232 bi directional interface and real time clock RTC NOTE For Approved applications CBK M Sc...

Страница 5: ...ating Temperature 10 C to 40 C 14 F to 104 F Power supply 115 230 VAC Mains 50 60 Hz or 9 VDC 800 mA through an external adapter Battery Internal rechargeable battery 90 hours operation Calibration No...

Страница 6: ...struction under pan Sample is moving animal weighing Vibrations through table Temperature changed dramatically Electronics faulty or Battery low Weight value incorrect Calibration error Recalibrate Un...

Страница 7: ...e pan when zeroing the scale Platform is not installed Improper calibration of the scale Damaged load cell Damaged Electronics Err 6 A D count is not correct when turning the scale on Load cell is dam...

Страница 8: ...d 9 Power supply battery charger circuits DU5 T2 6 0 LOAD CELL DAMAGE The most common reason why a scale fails is that the load cell has been damaged The damage can be from 2 primary causes The first...

Страница 9: ...THE LOAD CELL 10 VOLT POWER SUPPLY Vout 0 028 VOLTS 28mv BETWEEN S AND s This will cause the bridge to become unbalanced When the bridge has a voltage across it from E to E then the signal output at...

Страница 10: ...ween S and S With no load the voltage should be approximate 0mv 3mv With a mass on the load cell the output voltage should increase The amount by which it increases will be dependent upon the sensitiv...

Страница 11: ...ifier IC This voltage is sent to the filter and then to the A D converter 7 0 CALIBRATION The CBK M Scales are sealed to prevent unauthorised calibration The calibration of the CBK M scale is accompli...

Страница 12: ...the base and cover If this seal is broken the scale must be sealed by the relevant authorities using either the lead wire seal or an acceptable seal between the cover and base 7 2 CALIBRATION PROCEDUR...

Страница 13: ...le to access the PCB Place a jumper through the hole into the pins If a jumper is not available short the pins Turn on the scale using the switch on the base P _ _ _ _ Enter 2006 and press Tare After...

Страница 14: ...CAP Select Capacity F4 int Initial Zero Range F5 rE Z Re Zero Range F6 SCS Successive Tare Enable F7 Cnt Display the A D counts F8 ZE M Set zero method F9 Ld M Set low voltage detect mode 8 1 F1 CALI...

Страница 15: ...he options Press Tare to accept the displayed value and return to the parameter or press the Zero key to return to the parameter without changing the value Then press Func to advance to the next param...

Страница 16: ...e options Press Tare to accept the displayed value and return to the parameter or press the Zero key to return to the parameter without changing the value Then press Func to advance to the next parame...

Страница 17: ...000 90 000 approx Typical value at full capacity is 500 000 approx 8 8 F8 ZERO This parameter allows the normal method of setting zero To enter this parameter press the Tare key when F8 ZE M is shown...

Страница 18: ...lue Then press Func to advance to the first parameter Pressing Zero will display JP on indicating the jumper is still in place Switch off the scale and remove the jumper NOTE TO SECURE THE SCALE IT IS...

Страница 19: ...9 0 WIRING DIAGRAM Adam Equipment Company 2007 17...

Страница 20: ...10 0 MECHANICAL ASSEMBLY Adam Equipment Company 2007 18...

Страница 21: ...mpatibilit lectromagn tique This declaration is only valid when accompanied by a Certificate of Conformity issued by a Notified Body Diese Erkl rung gilt nur in Verbindung mit einer Konformit tsbesche...

Страница 22: ...edical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of...

Отзывы: