RECOMMENDATIONS FOR THE BOILER
MAINTENANCE
Essential recommendations for the electrical
safety
• Before opening the boiler for maintenance,
turn off the boiler by pushing on the ON/
OFF master switch.
• Isolate the external power supply of
the appliance before performing any
operation, unless it is required to take
measurements or perform system setup.
Essential recommendations for safety
• Water flowing out of the drain valve may
be extremely hot and could cause severe
scalding.
• Do not use solvents to clean any of the
components. The components could be
damaged, resulting in unreliable or unsafe
operation.
Essential recommendations for the correct
operation of the appliance
• It is recommended to have the boiler
serviced at least once a year or every
1,500 hours by a qualified technician,
preferably at the start of the heating
season. More frequent servicing may be
required depending on boiler use. Please
consult your installer for advice.
• The boiler maintenance will be carried out
by a qualified engineer, and the defective
parts may only be replaced by genuine
factory parts.
• Make sure to replace any gaskets or
seals on the removed components before
reinstalling them.
• Control the tightness of the hydraulic
circuit connections.
BOILER SHUT-DOWN FOR
MAINTENANCE
1. Switch the boiler off using the ON/OFF master
switch
2. Isolate the external power supply.
DRAINING THE BOILER
Set-up conditions
•
Boiler shut down through the ON/OFF switch
•
External power supply isolated (through the exter-
nal electrical box)
•
Boiler cooled down (if it was in operation)
•
Top cover removed to access the air vent. Refer
to
"Removal and Installation of the Access Panels" on
page 10.
Procedure
1. Close the heating circuit isolating valves (
1
)
2. Open the draining valve (
2
) and allow the water
to flow to the drain
3. Actuate the automatic air vent (
3
).
Follow-on Task(s)
Reinstall the access panels, refer to
"Removal and
Installation of the Access Panels" on page 10.
Cold water
Hot water
1
1
2
3
EN
Maintenance
Содержание E-tech P 115
Страница 20: ...ACV International Oude Vijverweg 6 B 1653 Dworp Belgium belgium service acv com www acv com...
Страница 21: ...E Tech P 57 115 144 201 259 A1007843_664Y7900 A ML...
Страница 36: ...16 2 3 1 7 6 4 5 8 9 10 11 12 13 14 15 16 17 18 ML...
Страница 40: ...ACV International Oude Vijverweg 6 B 1653 Dworp Belgium belgium service acv com www acv com...