SAFETY INSTRUCTIONS FOR THE
ELECTRICAL INSTALLATION
• Electrical connections must be carried
out by a qualified technician, in
accordance with regulations applicable
to electrical systems.
• Make sure that the boiler is connected
to the earth.
• As far as the power input to the boiler is
concerned, the installation must comply
with standard EN 60364-1 that define the
applicable levels of insulation, and with
all provisions applicable to installation
conditions.
• For protection against electrical hazard,
it is always recommended to install a
differential cut-out device (Ground Fault
Isolator) on the power supply circuit,
upstream of the boiler.
• The control circuit is protected by a 3A
magnetic circuit breaker.
• The default electrical safeties integrated
in the boiler protect the internal parts of
the boiler.
• Any additional electrical safety device
must be installed outside the boiler.
• For protection against overheating, it is
advisable to place an external positive
safety power cut-out, controlled by the
boiler safety thermostat.
ELECTRICAL CONNECTIONS
1. Remove the right and top panel of the boiler,
see
"Removal and Installation of the Access Pan-
els" on page 10
.
2. Connect the single phase 230 V power supply
on the control circuit connector, as well as all the
accessories (room thermostat, etc...)
3. Pass the power cables through the glands locat-
ed at the bottom of the rear panel.
Models
Std glands
optional
glands (*)
E-Tech P 57
1 x PG 36
4 x PG 21
E-Tech P 115
1 x PG 48
4 x PG 21
E-Tech P 144
1 x PG 48
4 x PG 21
E-Tech P 201
4 x PG 29
1 x PG 48
E-Tech P 259
4 x PG 29
1 x PG 48
4. Connect the boiler to the earth using a ring terminal.
5. Open the power connection box.
6. Remove the bottom protection.
7. Connect the power
wires to the mains us-
ing ring terminals.
* Optionally, the installer has the
possibility to remove the standard
cable glands and install the optional
cable glands (not supplied) on site.
** A transformation kit is supplied
with the boiler in order to connect
the power wires using compression
terminals (see detailed instructions
sheet in the kit).
Optional connection**
3
4
1
2
5
6
EN
Installation
Содержание E-tech P 115
Страница 20: ...ACV International Oude Vijverweg 6 B 1653 Dworp Belgium belgium service acv com www acv com...
Страница 21: ...E Tech P 57 115 144 201 259 A1007843_664Y7900 A ML...
Страница 36: ...16 2 3 1 7 6 4 5 8 9 10 11 12 13 14 15 16 17 18 ML...
Страница 40: ...ACV International Oude Vijverweg 6 B 1653 Dworp Belgium belgium service acv com www acv com...