Configuring the DataBridge SDR2-CF
SDR2-CF/SDR2-OEM-CF Configuration Guide rev 1.0
12
2.1 Setting date and time
The SDR2-CF features a real-time clock that reports a file’s last modified
date and time. The real-time clock is preset and battery-backed, so setting
the date and time is seldom necessary.
To set the time, type
1
at the menu prompt. Then, when prompted further,
enter the time in 24-hour format using two digits for each of hours, minutes,
and seconds (omit the colons (
:
) between each field). Press any key to
return to the SDR2-CF main menu. For an example, see Figure 2.1.
Figure 2.1. Setting the SDR2-CF’s time.
To set the date, type
2
at the menu prompt. Then, enter the date using two
digits for each of the month and day fields, and four digits for the year field
(omitting any hyphens or other characters). Press any key to return to the
main configuration menu. See Figure 2.2 for an example.
TIP:
For detailed
information about the
SDR2-CF
configuration menus,
see Chapter 4.