CP05 - CP10 Control Interface Insert

Doc. No.0525-035  

Ver. 6 220307

CP05 & CP10 CONTROL INTERFACE INSTALLATION GUIDE

 INTRODUCTION

This guide covers the installation and application of ActronAir CP05 and CP10 control interfaces. Functions, 

graphic displays and operations of both control interfaces are identical, therefore the two interfaces can be 

interchangeable parts and can also be combined as a dual control with mimic logic. Except for the character 

height, some difference in button symbols, and the physical size, shape and colour of the casings, both control 

interfaces provide the control flexibilty required for your air conditioning system's optimum operation. Note that 

there is also a minor difference in addressing the Mimic display procedures, which is explained in the affected 

steps below.   

The CP05 and CP10 graphic display are electronic devices which are compatible with ActronAir commercial 

control systems. The control interfaces allow complete management of graphics by the display of icons, 

management of international fonts and acoustic signal through piezoelectric buzzer. The display icons are 

defined at the application software development level while the fonts are in two sizes of 6x8 and 12x16 pixels. 

The application software resides on the outdoor controller, therefore the control interfaces does not require any 

additional software for operation. 

The standard control set up for the Hercules and Large Commercial units provides a single display monitor. This 

is either a CP05 or CP10 Control Interface which is mounted on the unit's electrical panel. There are situations 

where monitoring is required away from the unit, such as in a control room or in bulding management office. 

The ideal solution to such requirement is to provide a secondary control interface, which acts as a dual control 

interface. The secondary control interface will be wired to the system and can be mounted away from the unit. 

The dual control interfaces mimic each other, however the control interface most recently accessed has the 

priority over the other. For your dual control interface, you may have an option to use two CP05, two CP10 or one 

CP05 and one CP10, depending on your situation and requirement.  

The following procedures will dicuss the installation, configuration, specifications, components required and 

addressing the Mimic display of your dual control interface.   

1. 

1. Read all instructions in this manual before operating the air conditioning unit. Failure to do so may result in 

Read all instructions in this manual before operating the air conditioning unit. Failure to do so may result in 

damage to the unit and void your warranty.

damage to the unit and void your warranty.

2. 

2. Turn-Off power from mains supply by removing fuse or switching the circuit breaker to the "Off" position 

Turn-Off power from mains supply by removing fuse or switching the circuit breaker to the "Off" position 

before installation or servicing this control interface.

before installation or servicing this control interface.

3. 

3. Follow sound Lock Out & Tag Out procedures to ensure that power supply is not re-energised accidentally. 

Follow sound Lock Out & Tag Out procedures to ensure that power supply is not re-energised accidentally. 

4. 

4. This control interface has power supply from the control board via telephone connector, with voltage of 

This control interface has power supply from the control board via telephone connector, with voltage of 

18-30VDC Class II & maximum power input of 0.5W. Ensure that this unit is not installed on voltages higher 

18-30VDC Class II & maximum power input of 0.5W. Ensure that this unit is not installed on voltages higher 

than 30V DC supply.

than 30V DC supply.

5. 

5. Ensure that the unit installation complies with relevant council regulations and building code standards. 

Ensure that the unit installation complies with relevant council regulations and building code standards. 

All electrical wiring must be in accordance with current electrical authority regulations and all wiring 

All electrical wiring must be in accordance with current electrical authority regulations and all wiring 

connections to be as per electrical diagram provided.

connections to be as per electrical diagram provided.

6. 

WH&S rules and regulations must be observed and will take precedence during installation process.

7. Only use this Control Interface with an ActronAir air conditioner as described in this installation guide.

SAFETY PRECAUTIONS

   

   

    

1. 

1.  Please read this guide thoroughly and understand the procedure before performing the installation and 

Please read this guide thoroughly and understand the procedure before performing the installation and 

configuration of your Control Interface.

configuration of your Control Interface.

2. 

2. 

Only 

Only 

qualified technicians

qualified technicians

**

 are allowed to perform these procedures. 

 are allowed to perform these procedures. 

The customer, both end user, specifier 

and installer, assume all liability and risks relating to the configuration of the product in order to reach the 

expected results in relation to the specific design and system installation. Actron Air, based on specific 

agreements, may be consulted for the positive commissioning, installation and application of the unit, however 

in no case does it accept liability for the correct operation of the final equipment / system.

IMPORTANT NOTES

* * 

Qualifications required will be appropriate Electrical, Refrigeration and Refrigerant Handling License & Training, dependent on local State/Territory regulations.

Содержание CP05

Страница 1: ...TION GUIDE CONTROL INTERFACE Please Read This Guide Congratulations on your purchase of an ActronAir Control Interface This device has been designed and manufactured with the highest quality standard in mind We hope that you will be satisfied with your excellent choice Please read this guide thoroughly and keep it near the unit for future reference Model CP05 Model CP10 Esc Prg APPLICABLE TO HERCU...

Страница 2: ...e to the unit and void your warranty 2 2 Turn Off power from mains supply by removing fuse or switching the circuit breaker to the Off position Turn Off power from mains supply by removing fuse or switching the circuit breaker to the Off position before installation or servicing this control interface before installation or servicing this control interface 3 3 Follow sound Lock Out Tag Out procedu...

Страница 3: ...ximum pLAN length 500m with 6 Core 3 Pair Twisted Pair 7 0 20 AWG24 Shielded Data Cable Max OD Controller terminal distance Wires must be approved for 75o C temp 50m with 6 Core Flat 7 0 12 AWG28 Telephone Cable 500m with 6 Core 3 Pair Twisted Pair 7 0 20 AWG24 Shielded Data Cable Materials Transparent front panel cover glass frame Transparent polycarbonate Charcoal grey container back piece Polyc...

Страница 4: ...a bus layout with branches not exceeding 5m Maximum pLAN length 500m with 6 Core 3 Pair Twisted Pair 7 0 20 AWG24 Shielded Data Cable Max OD Controller terminal distance 50m with 6 Core Flat 7 0 12 AWG28 Telephone Cable 500m with 6 Core 3 Pair Twisted Pair 7 0 20 AWG24 Shielded Data Cable Materials Transparent front panel cover glass frame Transparent polycarbonate Charcoal grey container back pie...

Страница 5: ...section T Step 1 Remove CP05 Control Interface Panel PUSH 2 x Lateral Sliding Plastic Brackets 1 each side Back Piece Control Interface Pull out the Lateral Sliding Plastic Brackets from the Control Interface Step 3 Step 2 CONTROL INTERFACE CP05 REMOTE MOUNTING PROCEDURES Step 1 Prepare a panel for mounting the Control Interface with cut out dimensions as shown above NOTE Use a Blank Cover Plate t...

Страница 6: ...PUSH Panel Back Piece Control Interface PUSH 2 x Lateral Sliding Plastic Brackets 1 each side Front Panel Control Interface CONTROL INTERFACE CP10 MOUNTING DETAILS Dimensions Control Interface Mounting Cut Out Details 2 x ø2 5mm Holes 127mm 134mm 34 5mm 69mm 18mm 30 67mm Esc Prg 82mm 156mm 125mm CONTROL INTERFACE CP10 REMOTE MOUNTING PROCEDURE A PANEL MOUNT Front Cover Control Interface Panel Moun...

Страница 7: ...ly Front Cover Control Interface Control Interface Wall Mount Cover Control Interface Wall Mounting Cut Out 50mm x 70mm Suggested Step 1 Remove the Front Cover from the Control Interface assembly Step 2 Remove the Back Cover and the Gasket from the Control Interface assembly Step 3 Install the Control Interface onto the wall using mounting bracket and wall mount cover as shown below Tab Tab Use a ...

Страница 8: ...below RJ12 Plug Installer to Provide RJ12 Plug Installer to Provide VIEW FROM CABLE END VIEW FROM CABLE END 6 Core 3 Pair Twisted Pair 7 0 20 AWG24 Shielded Data Cable 200 Max Length Field Scope Installer to Provide 6 5 4 3 2 1 6 5 4 3 2 1 6 Core Flat 7 0 12 AWG28 Telephone Cable 50m Max Length Field Scope Installer to Provide See RJ12 Terminal Connections A below RJ12 Plug Installer to Provide RJ...

Страница 9: ... TX 12 Vdc 13 GND 14 6 Core 3 Pair Twisted Pair 7 0 20 AWG24 Shielded Data Cable 200 Max Length Field Scope Installer to Provide 6 Core Flat 7 0 12 AWG28 Telephone Cable 50m Max Length Field Scope Installer to Provide or CM100 Controller Supplied Fitted as Standard Esc Prg Return Temp 23 7 o C 16 5 o C Supply Temp Comp Rev Vlv 9 30 Unit On Auto Esc Prg Return Temp 23 7 o C 16 5 o C Supply Temp Com...

Страница 10: ...t 7 0 12 AWG28 Telephone Cable 50m Max Length Field Scope Installer to Provide or uPC Controller Supplied Fitted as Standard Esc Prg Return Temp 23 7 o C 16 5 o C Supply Temp Comp Rev Vlv 9 30 Unit On Auto Esc Prg Return Temp 23 7 o C 16 5 o C Supply Temp Comp Rev Vlv 9 30 Unit On Auto CP05 or CP10 may be used as Secondary Control Interface Refer Control Interface mounting procedure on pages 6 8 1...

Страница 11: ...Trm2 address to 31 by pressing the Enter Button two more times change the setting using the Button or Button and then press Enter Button again Make that terminal as Shared using the Button or Button and pressing the Enter Button Esc Prg P 01 Adr Priv Shared Trm1 32 Sh Trm2 31 Sh Trm3 None Ok No 1 TURN OFF the unit through the Master Control Control Interface 1 2 DISCONNECT the Master Control Inter...

Страница 12: ...mp 23 7 o C 16 5 o C Supply Temp Comp Rev Vlv 9 30 Unit On Auto CP10 Remote Mimic Control Control Interface 2 9 DISCONNECT the Remote Mimic Control Control Interface 2 from CM100 J15 for CM100 CONTROL INTERFACE for uPC terminal 10 RE CONNECT the Master Control Control Interface 1 back into CM100 J15 for CM100 CONTROL INTERFACE for uPC terminal and check whether the setting changes reflect both way...

Страница 13: ...THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 14: ...THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 15: ...THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 16: ... Copyright 2016 Actron Engineering Pty Limited ABN 34 002767240 Registered Trade Marks of Actron Engineering Pty Limited Document 0525 035 Issue Date 03 2022 Refrigerant Trading Authorisation No AU06394 ...

Отзывы: