05.03. BMS Monitoring
Provides the data about unit operation like refrigerant low/high pressures, temperature sensor values, Electronic Expansion
Valve (EEV) opening, fan speeds, zone status and digital inputs/outputs.
BMS Monitoring Points Table
Description
Digital / In
ver
ter
C
lassic II
Ty
p
e
M
o
dbus
R
egist
er
R
ead
/W
rit
e
UoM
M
in
M
ax
Unit S
tatus and C
onditions
BMS Card Software Version
l
l
Analog
405
R
1
0
65535
Alarm Output (0=Off, 1=On)
l
l
Analog
503
R
1
0
1
BMS Demand Mode (0=No BMS,
1=Basic BMS, 2=Advanced BMS)
l
l
Analog
505
R
1
0
2
Air Filter Notification (0=Off, 1=On)
l
l
Analog
506
R
1
0
1
Air Filter Run Timer (Hr)
l
l
Analog
509
R
1Hr
0Hr
10000Hr
Actual System Running Capacity (0.1%)
l
l
Analog
801
R
0.1%
0.0%
100.0%
Demand Response
(0 = No DRM, 1 = DRM1, 2 = DRM2,
3 = DRM3)
l
l
Analog
804
R
1
0
4
Remote On/Off (0=Low, 1=High)
l
l
Analog
805
R
1
0
1
Room Temperature (0.1°C)
l
l
Analog
851
R
0.1°C
-99.9°C
99.9°C
Outside Air Temperature (0.1°C)
l
Analog
852
R
0.1°C
-99.9°C
99.9°C
Unit F
aults
Current Error Code
(Consult the Air Conditioner unit’s
installation guide for Error Code
descriptions)
l
l
Analog
900
R
1
0
100
Error History Log, 1 Error ago
l
l
Analog
901
R
1
0
100
Error History Log, 2 Errors ago
l
l
Analog
902
R
1
0
100
Error History Log, 3 Errors ago
l
l
Analog
903
R
1
0
100
Error History Log, 4 Errors ago
l
l
Analog
904
R
1
0
100
Error History Log, 5 Errors ago
l
l
Analog
905
R
1
0
100
No Communications with Indoor Unit
(0=No Error, 1=Off line)
l
l
Analog
906
R
1
0
1
No Communications with Outdoor Unit
(0=No Error, 1=Off line)
l
l
Analog
909
R
1
0
1
Room Temperature Sensor Status
(0 = OK, 1 = Error)
l
l
Analog
951
R
1
0
1
Outside Air Temperature Sensor Status
(0 = OK, 1 = Error)
l
Analog
952
R
1
0
1
M
o
del
Outdoor Unit 1 Model
l
l
Analog
1001
R
1
0
65535
Outdoor Unit 1 Software Version
l
l
Analog
1002
R
1
0
65535
Compressor 1 Type
l
l
Analog
1004
R
1
0
100