9
2 . Connect the unit to the load side of the proper fan relay .
4 . Check indicator light for proper operation with fan on .
1 . Connect wires coming from the ActivePure
®
Induct Guardian unit as follows:
NOTE:
All units come standard with a blunt cord .
120 Volt Unit:
Black Wire L1
White Wire Neutral
Green Wire Ground
220 Volt Unit:
Black Wire L1
White Wire L2
Green Wire Ground
International Unit:
Brown Wire L1
Blue Wire L2
Green with
Yellow Stripe Ground
Disconnect power at the breaker or fuse panel before servicing unit.
Always follow OSHA lockout procedures to prevent accidental exposure
to electrical energy.
WARNING
3 . Be sure to ground the ballast by securing the unit to the metal surface
of the AC unit or power box .
Hard wiring unit into HVAC system should be done by a licensed HVAC
installer or qualified electrical contractor only.
CAUTION
WIRING THE UNIT
Your ActivePure
®
Induct Guardian unit requires no periodic maintenance
beyond normal replacement of the ActivePure
®
Cell every one (1) year .
The UV Bulb Indicator operation indicator on the face of the unit will glow
when the UV bulb is in use . If the indicator does not glow and the unit has
power, the ActivePure
®
Cell should be replaced .
NOTE:
For optimal performance and to maintain the Limited 5 year warranty,
it is required to replace the ActivePure
®
Cell once every year, even if
the UV bulb appears to be operating normally .
Lampe UV en marche lorsque le voyant est allumé.
UV Lamp in operation when lit.
HVAC ENVIRONMENTAL CONDITIONING SYSTEM
SYSTÈME DE CONDITIONNEMENT D’AIR CVC
MAINTENANCE / UV BULB INDICATOR
UV Bulb
Indicator