Installation and Commissioning Guide - MultiElite 2 Split System
Doc. No. 9590-5009
Ver. 1 211221
28
Installation and Commissioning Guide
Multi Split System
INTER-CONNECTING
POWER CABLE
OUTDOOR - INDOOR
SUB-MAIN
TO UNIT
OUTDOOR
UNIT
WALL
CONTROLLER
INTER-CONNECTING
PCB CABLE INDOOR
TO OUTDOOR
SUB-MAINS
CIRCUIT BREAKER
2
DATA CABLE
(Supplied with the
controller- 12 metres)
4
3
MAIN SUPPLY FROM
DISTRIBUTION BOARD
1
INDOOR
UNIT A
TO INDOOR
UNIT B, C, etc
3
EXTRA LOW VOLTAGE DATA CONTROL WIRING
2 core shielded data cable 14/0.20 (0.44mm
2
)
maximum 65 metres
EXTRA LOW VOLTAGE DATA CONTROL WIRING
4 core shielded data cable (0.75mm
2
)
maximum 12 metres
4
MAINS WIRING (220-240VAC)
(Single Phase + Neutral) 50Hz
CONTROL WIRING (220-240VAC)
(Single Phase + Neutral) 50Hz
2
1
SUB-MAINS
ISOLATOR
(Field Supplied by Installer)
Unit: m/ft.