actiLib Autoloader 1U
– User and Service Guide
Page 79 of 97
8.2
Tape loader error codes
If an error occurs during operation of the loader, the loader stops the current operation and
displays an error code on the LCD screen. Unless otherwise noted in Table 11 on page 85, try
to resolve the error by cycling power to the loader and retrying the last operation. If the error
persists, contact support personnel Support menu tree.
8.2.1 Example error code
EVENT -6
A5 F1
Where:
Sequence number
–6 indicates the position in sequence list, 0 being the most recent.
Log shows a load error (code A5 = fan error, sub code F1 = caused by the fan at the
back connector plate).
The event log with the loader also includes a date stamp for each event. Press Enter to display
the associated timestamp in the following format:
ddd:hh:mm:ss:HH
where:
ddd: days
hh: hours
mm: minutes
ss: seconds
HH: 1/100 second
A description of each error code and possible solution is provided in the following table
Error Code
Description
User Action
80
Barcode Reader Error,
cannot initialize BCR
Retry operation; after
several occurrences
contact technical support
81
Barcode Reader Error,
no response from BCR
Retry operation; after
several occurrences
contact technical support
82
EEPROM Error,
no response from EEPROM (located on
robotic controller)
Retry operation; after
several occurrences
contact technical support
83
Robotic controller generic problem
Reset the unit and retry
operation. After several
occurrences contact
technical support
84
Setting of gripper motor parameters failed
Reset the unit and retry
operation. After several
occurrences contact
technical support